108-94256 TEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 15

Technical content

24 JUN 2013 Rev A2

HV 8MM 90 DEG CONTACT SYSTEM HV 8mm 90 Grad Kontaktsystem Tyco Electronics Corporation, Harrisburg, PA 17105 *Trademark | Indicates change Product Information Center /telephonesolid +49 (0) 6251 1999 This specification is a controlled document.  Copyright 2000 by Tyco Electronics Corporation. All rights reserved 1 of 15 ECOC EGA0 LOC: AI Table of Contents 2. REFERENCED DOCUMENTS 3. REQUIREMENTS

3.1 Test Requirements and Procedures Summary…3

3.2 Product Qualification and Requalification Test

Fig.1 Electrical, mechanical and environmental Inhaltsverzeichnis 2. ZUSAETZLICHE UNTERLAGEN 3. REQUIREMENTS

3.1 Zusammenfassung der Prüfanforderungen und -

3.2 Produktvalidierung und Reihenfolge der

Fig.1 Elektrische, mechanische und Umwelts- Fig.2 Leistungsmerkmale an HV-Leitung 25mm² Cu…..…6 Fig.3 Leistungsmerkmale an HV-Leitung 35mm² Cu……..9 Fig.4 Leistungsmerkmale an HV-Leitung 50mm² Cu…...12

Rev. A2 2 of 15 1. SCOPE This specification covers performance, tests and quality requirements for the HV 8mm 90deg Contact System (P/N 2141212-1 mated with P/N 2141211-2) to be used with cable released by TE Connectivity Engineering. The released cables are listed in the application specification (see paragraph 2.1). This specification is restricted to the above mentioned contact system mated with pin P/N 9-2141223-1. 2. REFERENCED DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between the requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence. 2.1. TE Connectivity Documents 109-1: General Requirements for Test Specifications Customer Drawings c-2141211: HV 8mm, Deep Drawn Socket Pin 90° , Assembly c-2141212: HV 8mm, Deep Drawn Socket 90° , Assembly c-2141223: PIN DIA 8.0, CONTACT Application Specification 114-94083 2.2. Commercial Standards Test Guideline for Motor Vehicle Connect ors LV214 Edition: 2010/03 Requirements for HV-contact system LV215-1 Edition: 2010/03 3. REQUIREMENTS Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. 1. ZWECK Diese Spezifikation enthält die Leistungsmerkmale und die Prüf- und Qualitätsanforderungen für das HV 8mm 90 Grad Kontaktsystem (P/N 2141212-1 gesteckt in P/N 2141211-2) passend auf Leitungen freigegeben durch das TE Connectivity Engineering. Die freigegebenen Leitungen sind gelistet in der Verarbeitungsspezifikation (siehe Absatz 2.1). Diese Spezifikation schränkt sich ein auf das obengenannte Kontaktsystem gesteckt mit Pin P/N 9-2141223-1. 2. ZUSAETZLICHE UNTERLAGEN Die Unterlagen unten aufgelistet sind Teil dieser Spezifikation in sofern hier festgelegt ist. Wenn nicht anderweitig spezifiziert, ist die letzte Ausgabe des entspechenden Dokumentes anzuwenden. Bei eventuell auftretenden Unterschieden zwischen dieser Produktspezifikation und der Produktzeichung sind die Daten, die in den Produktzeichnungen enthalten sind, vorrangig maßgebend. Bei eventuell auftretenden Unterschieden zwischen dieser Produktspezifikation und den Unterlagen unten aufgelistet sind die Daten aus dieser Produktspezifikation vorrangig maßgebend. 2.1. TE Connectivity Unterlagen 109-1: Generelle Anforderungen für die Testdurchführungen Kundenzeichnungen c-2141211: HV 8mm, Tiefziehbuchse Pin 90° , Zusammenbau c-2141212: HV 8mm, Tiefziehbuchse 90° , Zusammenbau c-2141223: Rundkontakt 8.0, Kontakt Verarbeitungsspezifikationen 114-94083 2.2. Normen Prüfvorschrift für Steckverbinder LV214 Stand: 2010/03 Anforderungen an HV-Steckverbinder LV215-1 Stand: 2010/03 3. ANFORDERUNGEN Das Produkt muss die elektrischen, mechanischen und Umweltsanforderungen erfüllen die in Figur 1 spezifiziert sind.

Rev. A 3 of 15 3.1. Test Requirements and Procedures Summary according to LV 214 released March 2010. (German version see below / Deutsche Fassung siehe unten) Test description Requirement Verification TG 0 Receiving inspection /square4 Visual and dimensional inspection /square4 Contact resistance in contact area /square4 Contact resistance in connection area see LV215-1 Acc. DIN IEC-60 512-2, Test 1a and 2a Acc. DIN IEC 760 Measuring points see image, substract cable resistance from measured value TG 5 Characteristic curve of spring (Normal force) 1. Unused 2. After temperature storage Gap size and pull force were measured as normal force measurement is not possible 1. Gap size ≤ 7.4mm Pull force ≤ 60N 2. Gap size ≤ 7.7mm Pull force ≤ 60N No material adhesion between pin and socket Acc. DIN EN 60 068-2-2, Test Ba Gap size measured over 3 points of contact spring Pull force measured with HV 8mm pin 9-2141223- testing speed 50mm/min To = +180° C, 1000h TG 10 Conductor pull-out strength /square4 Ausreißkraft /head2right see LV215-1 (upto 50mm²) Acc. DIN IEC 60512-8 Test 16d /square4 Testing speed 50mm/min TG 11 /square4 Mating and unmating forces /square4 Durability /square4 Mating: max. 40 N /square4 Unmating: max. 60 N /square4 Insertion cycles *: Ag = 50 * tested with “HV 8mm Contact 90deg Assy” (interface contact) P/N 2141212-1 mated with HV 8mm pin P/N 9-2141223-1; the mating force during the test is allowed to change more than 25% compared to the initial value Acc DIN IEC 60 512-7, test 13b with HV 8mm pin 9-2141223-1 testing speed 50mm/min Acc. DIN IEC 60 512-5, test 9a TG 12 Current temperature rise, derating free in air See applicable current capability Fig. 2.1, 3.1 and 4.1 Acc. DIN IEC 60512-3 test 5a and 5b TG 14 Thermal time constant See Fig. 2.2, 3.2 and 4.2 upto 200s See Fig. 2.3, 3.3 and 4.3 upto 7200s 1-/2-/3-/4-/5- and 10- times the rated current /square4 Temperature / change of current / long term test /square4 Humidity heat, in cycles /square4 Temperature / change of current / long term test see LV215-1 The current carrying capability at 80° C environmental temperature after test must vary less then 20% of the initial value. Acc. DIN IEC 60 512-7, Test 13b Acc. DIN IEC 68-2-30 /head2right -40° C/+160° C, 1 cycle = 6 h, 60 cycles /head2right T rel. humidity 95%, 1 cycle = 1 day, 21 days Figure 1 (cont)

Rev. A2 4 of 15 Test description Requirement Verification TG 19 Environmental simulation 1. Temperature shock 2. Change of temperature 3. Storage under dry heat conditions 4. Industrial climate (multiple component climate) 5. Humidity heat, in cycles see LV215-1 Acc. DIN IEC 68-2-14 Na Acc. DIN IEC 68-2-14 Nb Acc. DIN EN 60 068-2-2, Test Ba Acc. DIN IEC 68-2-30,variant 2 Acc. DIN EN 60 068-2-27 1. -40° C/+180° C each 15 min, transposition time max. 10 s, 144 cycles 2. -40° C/+180° C each 3 h, transposition time max. 2 h, 20 cycles 3. 120 h, 180° C 4. 0.2 ppm SO 2, 0.01 ppm H 2S, 0.2 ppm NO 2, 0.01 ppm CI 2 / 25° C / 75% r. F. / 21 d, flow rate = 1 m³/h 5. rel. humidity 95% constant, 10 cycles each 24 h, T u = 25° C, T o = 55° C Figure 1 (end) 3.1. Zusammenfassung der Prüfanforderungen und –Verfahren nach LV214 Ausgabe März 2010 (English version see above / Englische Fassung siehe oben) Beschreibung Anforderung Prüfung PG 0 Eingangsprüfung /square4 Sicht- und Maßprüfung /square4 Durchgangswiderstand im Kontaktbereich /square4 Durchgangswiderstand im Anschlußbereich siehe LV215-1 Nach DIN IEC-60 512-2, Prüfung 1a und 2a Nach DIN IEC 760 Meßpunkte siehe Abbildung, Leitungswiderstand ist von Messwert zu subtrahieren. PG 5 Federkennlinie (Kontaktnormalkraft) 1. Neuzustand 2. nachTemperaturlagerung 1. Kontaktöffnungsmaß ≤ 7,4mm Abzugskraft ≤ 60N 2. Kontaktöffnungsmaß ≤ 7,7mm Abzugskraft ≤ 60N Nach DIN EN 60 068-2-2, Prüfung Ba Kontaktöffnung gemessung über 3 Punkte auf der Feder Abzugskraft gemessen mit HV 8mm Pin 9-2141223-1, Prüfgeschwindigkeit 50mm/min To = +180° C, 1000h PG 10 Leiterausreißkraft /square4 Ausreißkraft /head2right siehe LV215-1 (bis 50mm²) Nach DIN IEC 60 512-1-1, /square4 Prüfgeschwindigkeit 50mm/min Figur 1 (Fortsetzung auf nächster Seite)

Rev. A2 5 of 15 Beschreibung Anforderung Prüfung PG 11 /square4 Steck- und Ziehkräfte /square4 Steckhäufigkeit /square4 Stecken: max. 40 N /square4 Ziehen: max. 60 N /square4 Steckzyklen *: Ag = 50 * geprüft für “HV 8mm Kontact 90 Grad Assy” (Schnittstellenkontakt) P/N 2141212-1 gesteckt mit HV 8mm Pin P/N 9-2141223-1; die Steckkraft während Test darf um mehr als 25% ändern zu dem Initialwert Nach DIN IEC 60 512-7, Prüfung 13b mit Realpin P/N 9-2141223-1. Prüfgeschwindigkeit 50mm/min Nach DIN IEC 60 512-5, Prüfung 9a Nach DIN IEC 60512-8 Prüfung16d Prüfgeschwindigkeit 50mm/min PG 12 Stromerwärmung frei in Luft Siehe Derating Kurve Fig. 2.1, 3.1 and 4.1 Nach DIN IEC 60512-3 Prüfung 5a und 5b PG 14 Thermische Zeitkonstante Siehe Fig. 2.2, 3.2 und 4.2 upto 200s Siehe Fig. 2.3, 3.3 und 4.3 upto 7200s 1-/2-/3-/4-/5- und 10- fachen Nennstrom PG 15 Elektrischer Streßtest /square4 Temperatur-/Stromwechsel –Dauertest /square4 feuchte Wärme, zyklisch /square4 Temperatur-/Stromwechsel –Dauertest siehe LV215-1 Die Stromtragfähigkeit bei 80° C Umgebungstemperatur. darf nach der Prüfung um 20% verändern gegenüber dem Initialwert. Nach DIN IEC 60 512-7, Prüfung 13b Nach DIN IEC 68-2-30 /head2right -40° C/+160° C,

1 Zyklus = 6 h, 60 Zyklen

/head2right T rel. Feuchte 95%, 1Zyklus = 1Tag, 21 Tage PG 19 Umweltsimulation 1. Temperaturschock 2. Temperaturwechsel 3. Lagerung bei trockener Wärme 4. Industrieklima Mehrkomponentenklima 5. Feuchte Wärme, zyklisch siehe LV215-1 Nach DIN IEC 68-2-14 Na Nach DIN IEC 68-2-14 Nb Nach DIN EN 60 068-2-2, Prüfung Ba Nach DIN IEC 68-2-30, Variante 2 Nach DIN EN 60 068-2-27 1. -40° C/+180° C je 15 min, Umlagerungszeit max. 10 s, 144 Zyklen 2. -40ºC/+180ºC je 3 h, Zeit für Temp.Wechsel max. 2 h, 20 Zyklen 3. 120 h, 180ºC 4. 0.2 ppm SO 2, 0.01 ppm H 2S, 0.2 ppm NO 2, 0.01 ppm CI 2 / 25° C / 75% r. F. / 21 d, Volumenstrom = 1 m³/h 5. Rel. Feuchte 95% konstant, 10 Zyklen zu je 24 h, T u = 25° C, T o = 55° C Figur 1 (Ende)

Rev. A2 6 of 15 3.2. Product Qualification and Requalification Test Sequence SEE LV 214 RELEASED MARCH 2010 3.2. Produktvalidierung und Reihenfolge der Prüfungen Siehe LV 214 Ausgabe März 2010 Fig. 2 Performance with HV-cable 25mm² Cu / Leistungsmerkmale an HV-Leitung 25mm² Cu Fig. 2.1 Derating with HV-cable 25mm² Cu / Derating an HV-Leitung 25mm² Cu „Adapter“ Socket Pin 2141212-1 „Pin“ Crimp Pin (Not saleable)

Rev. A2 7 of 15 Fig. 2.2 Thermal time constant with HV-cable 25mm² Cu (time scale upto 200s) / Thermische Zeitkonstante an HV-Leitung 25mm² Cu (Zeitachse bis 200s)

Rev. A2 8 of 15 Fig. 2.3 Thermal time constant with HV-cable 25mm² Cu (time scale upto 5000s) / Thermische Zeitkonstante an HV-Leitung 25mm² Cu (Zeitachse bis 5000s)

Rev. A2 9 of 15 Fig. 3 Performance with HV-cable 35mm² Cu / Leistungsmerkmale an HV-Leitung 35mm² Cu Fig. 3.1 Derating with HV-cable 35mm² Cu / Derating an HV-Leitung 35mm² Cu „Pin“ Crimp Pin (Not saleable)

Rev. A2 10 of 15 Fig. 3.2 Thermal time constant with HV-cable 35mm² Cu (time scale upto 200s) / Thermische Zeitkonstante an HV-Leitung 35mm² Cu (Zeitachse bis 200s)

Rev. A2 11 of 15 Fig. 3.3 Thermal time constant with HV-cable 35mm² Cu (time scale upto 7200s) / Thermische Zeitkonstante an HV-Leitung 35mm² Cu (Zeitachse bis 7200s)

Rev. A2 12 of 15 Fig. 4 Performance with HV-cable 50mm² Cu / Leistungsmerkmale an HV-Leitung 50mm² Cu Fig. 4.1 Derating with HV-cable 50mm² Cu / Derating an HV-Leitung 50mm² Cu „Adapter“ Socket Pin 2141212-1 „Pin“ Crimp Pin (Not saleable)

Rev. A2 13 of 15 Fig. 4.2 Thermal time constant with HV-cable 50mm² Cu (time scale upto 200s) / Thermische Zeitkonstante an HV-Leitung 50mm² Cu (Zeitachse bis 200s)

Rev. A2 14 of 15 Fig. 4.3 Thermal time constant with HV-cable 50mm² Cu (time scale upto 7200s) / Thermische Zeitkonstante an HV-Leitung 50mm² Cu (Zeitachse bis 7200s)

Rev. A2 15 of 15 REVISION RECORD / Änderungsübersicht REV DESCRIPTION CHANGE RESPONSIBLE DATE A New document O. DE CLOET 01.MAR 2013 A1 Correct referenced figures of PG12 and 14 in figure 1 O. DE CLOET 05.MAR 2013 A2 Complete note in TG11 (25% change of mating force allowed) O. DE CLOET 24.JUN 2013 - - - - - - - - - - - -