A B C D E F H I J K L M N O P Q R S T V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Illustration may differ
Ordering information
Type Part no. V2D632R-MKMEB1 Flex 1074080 Other models and accessories www.sick.com/Lector63x Detailed technical data
Features
Focus Adjustable focus (manually) Sensor CMOS matrix sensor, grayscale values Sensor resolution 1,600 px x 1,200 px Light source Illumination LEDs: white (λ = 6,000 K ± 500 K) Feedback spot: visible green light (λ = 525 nm ± 15 nm), visible red light (λ = 630 ± 20 nm), RG 1 Aiming laser: visible red light (λ = 630 nm ... 680 nm) Laser class 1, complies with 21 CFR 1040.10 except for the tolerance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1 (2007-3)) Scanning frequency ≤ 50 Hz, at 1.9 megapixels resolution Code resolution ≥ 0.1 mm 1) Reading distance 50 mm ... 2,200 mm 1) 1) Depends on lens used, for details see field of view diagram. Performance Readable code structures 1D, 2D, Stacked Bar code types GS1-128 / EAN 128, UPC / GTIN / EAN, Interleaved 2 of 5, Pharmacode, GS1 DataBar, Code 39, Code 128, Codabar, Code 32, Code 93, USPS (Postnet, Planet, USPS4SCB), Australian Post, Dutch KIX Post, Royal Mail, Swedish Post 2D code types Data Matrix ECC200, GS1 Data-Matrix, MaxiCode, QR code Stacked code types PDF417 Code qualification On the basis of ISO/IEC 16022, ISO/IEC 15415, ISO/IEC 18004 Interfaces Ethernet TCP/IP ✔, TCP/IP Function Host, AUX, FTP (image transmission) Data transmission rate 10/100/1,000 Mbit/s
2 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-04-07 16:36:27
Subject to change without notice
V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS PROFINET ✔ Function PROFINET Dual Port (optional via external connection module CDF600-2) EtherNet/IP™ ✔ Data transmission rate 10/100/1,000 Mbit/s Serial ✔, RS-232, RS-422 Function Host, AUX CAN ✔ Function SICK CAN sensor network (Master/Slave, Multiplexer/Server) Data transmission rate 250 kbit/s ... 500 kbit/s PROFIBUS DP ✔ Type of fieldbus integration Optional over external fieldbus module CDF600-2 USB ✔ Remark USB 2.0 Switching inputs 4 (“Sensor 1”, “Sensor 2”, 2 inputs via optional CMC600 parameter memory in CDB650/ CDM420) Configurable inputs Encoder input, external trigger Switching outputs 6 (CDB650: “Result 1”, “Result 2”, “Result 3”, “Result 4”, 2 external outputs via CMC600 or CDM420: “Result 1”, “Result 2”, 2 external outputs via CMC600 or cable with open end: “Re- sult 1”, “Result 2”, “Result 3”, “Result 4”) Configurable outputs Good read, External illumination control, free configurable output condition, "device ready" Reading pulse Switching inputs, non-powered, serial interface, Ethernet, CAN, auto pulse, presentation mode Optical indicators 11 LEDs (5 x status display, 5 x LED bar graph, 1 green/red feedback spot) Acoustic indicators Beeper (configurable) Operating elements 2 buttons (choose and start/stop functions) Configuration software SOPAS ET Memory card Micro SD memory card (flash card) max. 32 GB, optional Data storage and retrieval Image and data storage via microSD memory card, internal storage and external FTP Maximum encoder frequency 1 kHz External illumination control Via digital output (max. 24 V trigger) or via external illumination connector Mechanics/electronics Electrical connection 1 x M12, 17-pin plug (serial, CAN, I/Os, power supply) 1 x M12, 8-pin socket (Ethernet, 1 GBit/s) 1 x M8, 4-pin socket (USB) 1 x M12, 4-pin socket (external illumination control) Operating voltage 24 V DC, ± 20 % Power consumption Typ. 10 W, ± 20 % Output current ≤ 100 mA Housing Aluminum die cast Enclosure rating IP67 (EN 60529 (1991-10), EN 60529/A2 (2002-02)) Electrical safety EN 60950-1 (2011-01) Weight 590 g Dimensions (L x W x H) 108 mm x 63.1 mm x 96.4 mm Lens C-mount, focal length 16 mm, aperture 8 2017-04-07 16:36:27 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 3
A B C D E F H I J K L M N O P Q R S T V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Ambient data Electromagnetic compatibility (EMC) EN 61000-6-2 (2005-08) / EN 61000-6-4 (2007-01) + A1 (2011) Vibration resistance EN 60068-2-6 (2008-02) Shock resistance EN 60068-2-27 (2009-05) Ambient operating temperature 0 °C ... +50 °C Storage temperature –20 °C ... +70 °C Permissible relative humidity 90 %, Non-condensing Classifications ECl@ss 5.0 27280103 ECl@ss 5.1.4 27280103 ECl@ss 6.0 27280103 ECl@ss 6.2 27280103 ECl@ss 7.0 27280103 ECl@ss 8.0 27280103 ECl@ss 8.1 27280103 ECl@ss 9.0 27280103 ETIM 5.0 EC002550 ETIM 6.0 EC002550 UNSPSC 16.0901 43211701
4 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-04-07 16:36:27
Subject to change without notice
V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Dimensional drawing (Dimensions in mm (inch)) 59.1 45.8 min. 8 – max. 50 91.8 5.9 6.5 50 23.9 0.5 74.1 63.1 76.6 108 10.8 1 2 8 9 ä å æ ç ã ß à á â 96.4 ① External illumination connection ② Gigabit Ethernet port ③ USB port ④ Power, serial, CAN, and I/O connection ⑤ 22.7 mm, 37.7 mm, or 60 mm protective cover for optics ⑥ Protective caps/plugs to seal any electrical connections that are not in use ⑦ M5 blind tapped holes, 5 mm deep (4 x), for mounting the sensor ⑧ M5 sliding nut, 5.5 mm deep (4 x), pivoting, for an alternative method of mounting the sensor ⑨ Integrated illumination connection ⑩ Aiming laser (2 x) ⑪ S-mount or C-mount optics module ⑫ 2.5 mm blind tapped holes (4 x) for mounting the spacers for the integrable illumination ⑬ Optical axis and center of the image sensor ⑭ Manual focus screw, underneath cover/label (S-mount Flex) ⑮ Function button (2 x) ⑯ Bar graph display ⑰ Removable cover for microSD memory card slot and manual focus screw (S-mount) ⑱ LEDs for status display (2 levels), 5 x 2017-04-07 16:36:27 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 5
A B C D E F H I J K L M N O P Q R S T V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Field of view Field of view in mm² (sq inch) Min. resolution in mm (mil) 1D code 2D code Field of view in mm² (sq inch) Min. resolution in mm (mil) 1D code 2D code a: f = 8.0 mm (C-Mount standard only) b: f = 12.0 mm c: f = 16.0 mm d: f = 25.0 mm e: f = 35.0 mm f: f = 50.0 mm a b c e f d 200 (7.87) 400 (15.75) 600 (23.62) 800 (31.50) 1,000 (39.37) 1,200 (47.24) 1,400 (55.12) 1,600 (62.99) 1,800 (70.87) 2,000 (78.74) 2,200 (86.61) 200 x 150 (7.87 x 5.91) 400 x 300 (15.75 x 11.81) 600 x 450 (23.62 x 17.72) 800 x 600 (31.50 x 23.62) 1,000 x 750 (39.37 x 29.53) 1,200 x 900 (47.24 x 35.43) 0.4 (15.7) 0.6 (23.6) 0.8 (31.4) 0.1 (3.9) 0.3 (11.8) 0.5 (19.7) 0.7 (27.6) 0.9 (35.4) 0.2 (7.9) 1.2 (47.2) 1.4 (55.1) 1.0 (39.4) Working distance/focus position in mm (inch) 200 (7.87) 400 (15.75) 600 (23.62) 100 (3.94) 300 (11.81) 500 (19.69) 100 x 75 (3.94 x 2.95) 300 x 225 (11.81 x 8.86) Working distance/focus position in mm (inch) 400 x 300 (15.75 x 11.81) 200 x 150 (7.87 x 5.91) a b c e f d 0.4 (15.7) 0.1 (3.9) 0.2 (7.9) 0.3 (11.8) 0.2 (7.9) 0.15 (5.9) 0.25 (9.8) 0.35 (13.7) 0.05 (2.0) 0.1 (3.9) 0.3 (11.8) For S-mount and standard C-mount lenses, spacer rings are needed for working distances shorter than approximately 10 times the focal length. For compact C-mount lenses, spacer rings are not needed, but the built-in illumination cannot be used for distances shorter than 300 mm.
6 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-04-07 16:36:27
Subject to change without notice
V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Selection Guide Lector63x Compact C-mount Focal length 35 mm Aperture F8 2079344 Long – 37 mm 2079502 Focal length 12 mm Aperture F8 2079348 Medium – 15 mm 2079501 Focal length 16 mm Aperture F8 2079346 Long – 37 mm 2079502 Focal length 25 mm Aperture F8 2079343 Medium – 15 mm 2079501 Protective hood Lens Integratable lighting Assembled device, incl. all mentioned parts Medium, white 2078430 Medium – 37.7 mm 2079127 Body, incl. C-mount module Lector631 V2D631R-MXCXB0 1078473 Lector632 V2D632R-MXCXB0 1075881 Medium, blue 2083814 Medium, white 2078430 Long – 60 mm 2079204 Medium, blue 2083814 Long – 60 mm 2079204 Narrow, white 2078431 Medium – 37.7 mm 2079127 Narrow, blue 2083812 Medium – 37.7 mm 2079127 Narrow, white 2078431 Long – 60 mm 2079204 Narrow, blue 2083812 Long – 60 mm 2079204 Lector631, 16 mm, F8, white V2D631R-MKMEB1 1080076 Lector632, 25 mm, F8, white V2D632R-MWMFB4 1074081 Lector631, 25 mm, F8, white V2D631R-MWMFB4 1080077 Lector632, 35 mm, F8, white V2D632R-MWMGB1 1074082 Lector631, 35 mm, F8, white V2D631R-MWMGB1 1080078 Medium – 37.7 mm 2079127 Lector631, 12 mm, F8, white V2D631R-MKMDB4 1080075 Distance bracket and light extension connector Lector632, 12 mm, F8, white V2D632R-MKMDB4 1074079 Lector632, 16 mm, F8, white V2D632R-MKMEB1 1074080 2017-04-07 16:36:27 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 7
A B C D E F H I J K L M N O P Q R S T V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Focal length 8 mm Aperture F1.4–16 5325091 Focal length 12 mm Aperture F1.4–16 5325403 Lens protective hood Lens External lighting Assembled device, incl. all mentioned parts Medium – 37.7mm 2079127 Body, incl. C-mount module Long – 60 mm 2079204 Mounting bracket An external, application-specific lighting is required Focal length 16 mm Aperture F1.4–16 5325404 Bracket for ICL mounting 2081187 ICL280, red 1052472 ICL280, infrared 1057645 Focal length 25 mm Aperture F1.4–16 5325405 Bracket for ICL mounting 2081187 Hood to be used with ICL lighting 2081544 ICL260, red 1052495 ICL280, infrared 1057645 Focal length 35 mm Aperture F1.4–16 5325406 Bracket for ICL mounting 2081187 ICL300, red 1046820 ICL300, infrared 1047957 Focal length 50 mm Aperture F1.4–16 5325407 Bracket for ICL mounting 2081187 ICL300, red 1046820 ICL300, infrared 1047957 Lector631 V2D631R-MXCXB0 1078473 Lector632 V2D632R-MXCXB0 1075881
8 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-04-07 16:36:27
Subject to change without notice
V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Exploded view ß ① Camera housing ② Spacer for built-in illumination ③ Plug connector for illumination ④ Optical filter (optional) ⑤ Spacer disk (included with delivery of filter) ⑥ Compact C-mount lens ⑦ Built-in illumination ⑧ C-mount filter (optional), cannot be used with 15 mm lenses (2080213) ⑨ Filter holder ⑩ Protective cover for optics 2017-04-07 16:36:27 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 9
A B C D E F H I J K L M N O P Q R S T V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS ① Camera housing ② C-mount filter (optional) ③ Spacer disk (included with delivery of filter) ④ C-mount lens ⑤ Mounting bracket for ICL ring lighting ⑥ Protective cover for optics for ICL ring lighting ⑦ ICL ring lighting Recommended accessories Other models and accessories www.sick.com/Lector63x Brief description Type Part no. Mounting brackets and plates Mounting bracket with screws, L-shaped for mounting with sliding nuts, includes angle indicator for adjusting the tilt angle Mounting bracket 2078970 Terminal and alignment brackets Distance bracket and light extension connector (medium) for mounting integratable lighting, length 15 mm, used with compact C-mount lenses with focal length of 12 mm or 25 mm and S-mount lens with focal length 25mm Distance bracket 2079501 Modules Connection device basic for connecting one sensor with 2 A fuse, 5 cable glands and RS-232 interface to sensor via M12, 17-pin female connector, all outputs available on screw/spring-loaded terminals. CDB650-204 1064114 Plug connectors and cables Head A: female connector, M12, 17-pin, straight, A-coded Head B: male connector, M12, 17-pin, straight, A-coded Cable: Power, serial, CAN, digital I/Os, drag chain use, suitable for 2 A, suitable for re- frigeration, shielded, 2 m Connection cable (male connector - female connector) 6053230
10 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-04-07 16:36:27
Subject to change without notice
V2D632R-MKMEB1 Flex | Lector63x IMAGE-BASED CODE READERS Brief description Type Part no. Head A: male connector, M12, 8-pin, straight, X-coded Head B: male connector, RJ45, 8-pin, straight Cable: Gigabit Ethernet, shielded, 2 m Connection ca- ble (male connec- tor-male connector) 6049728 Lenses and accessories Compact C-mount lens 2/3", focal length 25 mm, mask 8 C-mount lens 2079343 Lens protective hood medium, enclosure rating IP 67, length 37.7 mm, PMMA, used with compact C-mount lenses with focal length of 12 mm or 25 mm and S-mount lens with focal length 25mm Optics pro- tection cover 2079127 Illuminations Integratable lighting, lighting color white, narrow, suitable for S-mount and compact C- mount lenses with a focal length of 25 mm and 35 mm VI55I-WH2023M0 2078431 2017-04-07 16:36:27 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 11
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com