STR1-SAFU0AC5 SICK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
NON-CONTACT SAFETY SWITCHES
A B C D E F H I J K L M N O P Q R S T STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES
Ordering information
Type Part no. STR1-SAFU0AC5 1069575 Other models and accessories www.sick.com/STR1 Detailed technical data
Features
System part Sensor and actuator Sensor principle Transponder Number of safe outputs 2 Auxiliary contact (AUX) 1 Safe switch on distance Sao Active front sensor surface 14 mm Active side sensor surface 9 mm Safe switch off distance Sar 28 mm Active sensor surfaces 3 Actuation directions 5 Coding Uniquely coded Safety-related parameters Safety integrity level SIL3 (IEC 61508), SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 5,21 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Type Type 4 (EN ISO 14119) Actuator coding level High coding level (EN ISO 14119) Safe state in the event of a fault At least one safety-related semiconductor output (OSSD) is in the OFF state. Interfaces Connection type Cable with plug M12, 5-pin Flexi-Loop-ready ✔ Length of cable 0.2 m Cable material PVC Diagnostics indicator ✔ Status display ✔
2 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES Electrical data Protection class III (IEC 61140) Classification according to cULus Class 2 Power consumption 50 mA Type of output Semiconductor (OSSD) Output current ≤ 100 mA Response time 40 ms 1) Enable time 100 ms 1) 2) Risk time 80 ms 1) 3) Switch-on time 2.5 s 4) 1) In a cascade, each downstream safety switch increases the system response time. More response times can be found in the operating instructions. 2) Response time on approach to the enable zone. 3) Detection time for internal oder external faults (e.g., short-circuit or cross-circuit of output signal switching devices). Follow the detailed information in the operating instructions. 4) The stated time applies for one sensor after application of the supply voltage to the safety switch. In case of a cascade 0.1 s must be added per sensor. For uniquely coded or permanently coded sensors 0.5 s must be added additionally per taught-in actuator. Mechanical data Dimensions (W x H x D) 40 mm x 18 mm x 26 mm Weight 68 g Housing material VISTAL® Ambient data Enclosure rating IP67 (EN 60529) IPX9K (ISO 20653) Ambient operating temperature –10 °C ... +70 °C Storage temperature –25 °C ... +70 °C Vibration resistance 10 Hz ... 55 Hz, 1 mm (IEC 60068-2-6) Shock resistance 30 g, 11 ms (IEC 60068-2-27) EMC EN IEC 61326-3-1 EN IEC 60947-5-2 EN IEC 60947-5-3 EN 300330 V2.1.1 Classifications ECl@ss 5.0 27272403 ECl@ss 5.1.4 27272403 ECl@ss 6.0 27272403 ECl@ss 6.2 27272403 ECl@ss 7.0 27272403 ECl@ss 8.0 27272403 ECl@ss 8.1 27272403 ECl@ss 9.0 27272403 ETIM 5.0 EC001829 ETIM 6.0 EC001829 UNSPSC 16.0901 39122205 2018-09-06 10:37:18 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 3
A B C D E F H I J K L M N O P Q R S T STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES Dimensional drawing (Dimensions in mm (inch)) Sensor with cable and male connector (0.71) (0.55) M12 x 1 13.5 (0.53) Ø 5.5 (Ø 0.22) (0.75) 26.2 (1.03) (1.57) (0.99) 175 (6.89) (0.12) (0.2) Ø 8.5 (Ø 0.33) (0.87) “Flat” actuator (0.71) (0.35) (0.94) Ø 4.5 (Ø 0.18) Ø 8.5 (Ø 0.34) (Ø 0.2) 40 (1.57)
4 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES Response range “Flat”/"Mini" actuator, active side sensor surface –40 (–1.57) –20 (–0.79) (0.79) (1.57) 0 4 (0.16) (0.31) (0.47) (0.63) (0.79) [mm] (inch) Safe switch on distance SAo 9 mm.Pay attention to boundary areas in case of parallel approach: If the actuator moves laterally in re- lation to the surface of the sensor, a minimum distance of 4 mm must be maintained. This distance will prevent premature trigger- ing due to the side approach areas. “Flat”/"Mini" actuator, active front sensor surface –40 (–1.57) –20 (–0.79) (0.79) (1.57) 0 4 (0.16) (0.31) (0.47) (0.63) (0.79) [mm] (inch) Safe switch on distance SAo 14 mm.Pay attention to boundary areas in case of parallel approach: If the actuator moves laterally in relation to the surface of the sensor, a minimum distance of 10 mm must be maintained. This distance will prevent premature trig- gering due to the side approach areas. 2018-09-06 10:37:18 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 5
A B C D E F H I J K L M N O P Q R S T STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES Connection diagram Voltage supply 24 V DC OSSD 1 Voltage supply 0 V DC OSSD 2 Aux output (not safe) 2 1 Connection single sensor /c50 /c51 /c49 ① Safe evaluation unit ② Connecting cable with 5-pin, M12 female connector and flying leads (e.g., YF2A15-xxxVB5XLEAX) ③ STR1 transponder safety switch (e.g., STR1-SAxx0AC5) Series connection Series connection with Flexi Loop (with diagnostics) /c51 /c51 /c52/c53 /c57/c53/c50/c49 /c53 /c53 /c54 /c55 /c55 /c56 ① Flexi Soft safety controller ② Connecting cable with 5-pin, M12 female connector and flying leads (e.g., YF2A15-xxxVB5XLEAX) ③ FLN-OSSD1000105 Flexi Loop node ④ FLN-EMSS1100108 Flexi Loop node ⑤ Connection cable with 5-pin, M12 male connector and 5-pin, M12 female connector (e.g., YF2A15-xxxUB5M2A15) ⑥ Connection cable with 8-pin, M12 male connector and 8-pin, M12 female connector (e.g., YF2A18-xxxUA5M2A18) ⑦ STR1 transponder safety switch (e.g., STR1-SAxx0AC5) ⑧ Safety locking device (e.g., i10-x0454 or i110-x0454) ⑨ FLT-TERM00001 Flexi Loop terminating element
6 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES STR1 transponder safety switch to RLY3-OSSD2 safety relay K2 K1 +24 V DC 0 V PLC Reset E212770/00/2018-06-07 R1 Y1 Y2 24 A2 14 S1 I1 I2 23 A1 13 RL Y3-OSSD2 3 2 4 1 5STR1 State RES Parallel connection of two STR1 transponder safety switches to a Flexi Classic safety controller UE410-MU/XU PLC I4 I3 A2 K1 K2 EN FE I2 I1 I1 I2 X1 X2 Q3 Q2 Function S1 S2 S3 Reset +24 V DC 0 V FE E148463/00/2016-02-08 STR1 3 4 52 STR1 3 4 52 2018-09-06 10:37:18 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 7
A B C D E F H I J K L M N O P Q R S T STR1-SAFU0AC5 | STR1 NON-CONTACT SAFETY SWITCHES Recommended accessories Other models and accessories www.sick.com/STR1 Brief description Type Part no. Nuts and screws 10 pieces Safety screws M4 x 14 5333570 Plug connectors and cables Head A: female connector, M12, 5-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 2 m YF2A15-020VB5XLEAX 2096239 Head A: female connector, M12, 5-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 5 m YF2A15-050VB5XLEAX 2096240 Head A: female connector, M12, 5-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PVC, unshielded, 10 m YF2A15-100VB5XLEAX 2096241
8 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com