NON-CONTACT SAFETY SWITCHES
A B C D E F H I J K L M N O P Q R S T STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES
Ordering information
Type Part no. STR1-SASM0AC8 1069561 Other models and accessories www.sick.com/STR1 Detailed technical data
Features
System part Sensor and actuator Sensor principle Transponder Number of safe outputs 2 Auxiliary contact (AUX) 1 Safe switch on distance Sao Active front sensor surface 10 mm Active side sensor surface 6 mm Safe switch off distance Sar 25 mm Active sensor surfaces 3 Actuation directions 5 Coding Universally coded Safety-related parameters Safety integrity level SIL3 (IEC 61508), SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 5,21 x 10-9 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Type Type 4 (EN ISO 14119) Actuator coding level Low coding level (EN ISO 14119) Safe state in the event of a fault At least one safety-related semiconductor output (OSSD) is in the OFF state. Functions Cascading ✔ Interfaces Connection type Cable with plug M12, 8-pin Length of cable 0.2 m Cable material PVC Diagnostics indicator ✔
2 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES Status display ✔ Electrical data Protection class III (IEC 61140) Classification according to cULus Class 2 Power consumption 50 mA Type of output Semiconductor (OSSD) Output current ≤ 100 mA Response time 40 ms 1) Enable time 100 ms 1) 2) Risk time 80 ms 1) 3) Switch-on time 2.5 s 4) 1) In a cascade, each downstream safety switch increases the system response time. More response times can be found in the operating instructions. 2) Response time on approach to the enable zone. 3) Detection time for internal oder external faults (e.g., short-circuit or cross-circuit of output signal switching devices). Follow the detailed information in the operating instructions. 4) The stated time applies for one sensor after application of the supply voltage to the safety switch. In case of a cascade 0.1 s must be added per sensor. For uniquely coded or permanently coded sensors 0.5 s must be added additionally per taught-in actuator. Mechanical data Dimensions (W x H x D) 40 mm x 18 mm x 26 mm Weight 82 g Housing material VISTAL® Ambient data Enclosure rating IP67 (EN 60529) IPX9K (ISO 20653) Ambient operating temperature –10 °C ... +70 °C Storage temperature –25 °C ... +70 °C Vibration resistance 10 Hz ... 55 Hz, 1 mm (IEC 60068-2-6) Shock resistance 30 g, 11 ms (IEC 60068-2-27) EMC EN IEC 61326-3-1 EN IEC 60947-5-2 EN IEC 60947-5-3 EN 300330 V2.1.1 Classifications ECl@ss 5.0 27272403 ECl@ss 5.1.4 27272403 ECl@ss 6.0 27272403 ECl@ss 6.2 27272403 ECl@ss 7.0 27272403 ECl@ss 8.0 27272403 ECl@ss 8.1 27272403 ECl@ss 9.0 27272403 ETIM 5.0 EC001829 2018-09-06 10:37:18 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 3
A B C D E F H I J K L M N O P Q R S T STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES ETIM 6.0 EC001829 UNSPSC 16.0901 39122205 Dimensional drawing (Dimensions in mm (inch)) Sensor with cable and male connector (0.71) (0.55) M12 x 1 13.5 (0.53) Ø 5.5 (Ø 0.22) (0.75) 26.2 (1.03) (1.57) (0.99) 175 (6.89) (0.12) (0.2) Ø 8.5 (Ø 0.33) (0.87) "Standard" actuator (0.71) Ø 4.5 (Ø 0.18) (0.75) (0.87) 26.2 (1.03) (0.2) Ø 8.5 (Ø 0.33) 40 (1.57)
4 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES Response range "Standard" actuator, active side sensor surface –40 (–1.57) –20 (–0.79) (0.79) (1.57) 0 4 (0.16) (0.31) (0.47) (0.63) (0.79) [mm] (inch) Safe switch on distance SAo 6 mm "Standard" actuator, active front sensor surface –40 (–1.57) –20 (–0.79) (0.79) (1.57) 0 4 (0.16) (0.31) (0.47) (0.63) (0.79) [mm] (inch) Safe switch on distance SAo 10 mm. Pay attention to boundary areas in case of parallel approach: If the actuator moves laterally in relation to the surface of the sensor, a minimum distance of 6 mm must be maintained. This distance will prevent premature trig- gering due to the side approach areas. 2018-09-06 10:37:18 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 5
A B C D E F H I J K L M N O P Q R S T STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES Connection diagram Aux output (not safe) Voltage supply 24 V DC Not connected Enable input for OSSD 2 OSSD 1 OSSD 2 Voltage supply 0 V DC Enable input for OSSD 1 2 1 3 7 Connection single sensor /c50 /c51 /c49 ① Safe evaluation unit ② Connecting cable with 8-pin, M12 female connector and flying leads (e.g., YF2A18-xxxUA5LEAX) ③ STR1 transponder safety switch (e.g., STR1-SAxx0AC8)
6 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES Series connection Series connection with T-piece (without diagnostics) /c50/c49 /c51 /c51 /c51/c52 /c52 /c53 /c55 /c54 /c55 /c54 /c55 /c54 ① Safe evaluation unit ② Connecting cable with 4-pin, M12 female connector and flying leads (e.g., YF2A14-xxxVB3XLEAX) ③ TR4-AK004C T-connector ④ Connection cable with 4-pin, M12 male connector and 4-pin, M12 female connector (e.g., YF2A14-xxxVB3M2A14) ⑤ MLP1-XXT end connector ⑥ Connection cable with 8-pin, M12 male connector and 8-pin, M12 female connector (e.g., YF2A18-xxxUA5M2A18) ⑦ STR1 transponder safety switch (e.g., STR1-SAxx0AC8) 2018-09-06 10:37:18 | Online data sheet Subject to change without notice SAFETY SWITCHES | SICK 7
A B C D E F H I J K L M N O P Q R S T STR1-SASM0AC8 | STR1 NON-CONTACT SAFETY SWITCHES Series connection of three STR1 transponder safety switches to a Flexi Classic safety controller UE410-MU/XU +24 V DC Function Q1 I4 I3 A2 EN Q3 Q2 Q4 A1 I2 I1 X1 X2 S1 S2 S3 FE Reset 0 V FE E148462/00/2016-02-08 STR1 2 4 38 7 6 15 STR1 2 4 38 7 6 15 STR1 2 4 38 7 6 15 Recommended accessories Other models and accessories www.sick.com/STR1 Brief description Type Part no. Nuts and screws 10 pieces Safety screws M4 x 20 5333571 Plug connectors and cables Head A: female connector, M12, 8-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 2 m YF2A18-020UA5XLEAX 2095652 Head A: female connector, M12, 8-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 5 m YF2A18-050UA5XLEAX 2095653 Head A: female connector, M12, 8-pin, straight, A-coded Head B: Flying leads Cable: Sensor/actuator cable, PUR, halogen-free, unshielded, 10 m YF2A18-100UA5XLEAX 2095654
8 SAFETY SWITCHES | SICK Online data sheet | 2018-09-06 10:37:18
Subject to change without notice
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com