A B C D E F H I J K L M N O P Q R S T S30B-3011GB | S300 Expert SAFETY LASER SCANNERS system plug not supplied with delivery

Ordering information

Type Part no. S30B-3011GB 1057641 The system plug has to be ordered separately. For details, see “Accessories”. Other models and accessories www.sick.com/S300_Expert Detailed technical data

Features

Protective field range 3 m Warning field range 8 m (at 15 % reflectivity) Distance measuring range 30 m Type of field set Triple field sets Number of field sets 16 Number of fields 48 Number of monitoring cases 32 1) Scanning angle 270° Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm, 150 mm Angular resolution 0.5° Response time 80 ms 2) Protective field supplement 100 mm Number of multiple samplings 2 ... 16, configurable Delay of automatic reset 2 s ... 60 s, configurable 1) In combination with an additional static input via EFI or using the dynamic inputs on the device. Otherwise eight. 2) Depending on basic response time and multiple sampling. Safety-related parameters Type Type 3 (IEC 61496) Safety integrity level SIL2 (IEC 61508) SILCL2 (EN 62061) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 8.0 x 10-8 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state.

2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

S30B-3011GB | S300 Expert SAFETY LASER SCANNERS Functions Restart interlock ✔ External device monitoring (EDM) ✔ Multiple sampling ✔ Monitoring case switching ✔ Static protective field switching ✔ Dynamic protective field switching ✔ Contour as a reference ✔ Integrated configuration memory ✔ Measured data output ✔ Extended measured data output (CMS) ✔ Safe SICK device communication via EFI ✔ Interfaces Connection type System plug with or without connecting cable Universal I/Os 5 1) Inputs External device monitoring (EDM) 1 2) Reset/restart 1 2) Static control inputs 3 3) Static control inputs with EFI 5 4) Dynamic control inputs (incremental encoder) 2 5) Standby 1 Outputs OSSD pairs 1 Diagnostic outputs 3 6) Configuration method PC with CDS (Configuration and Diagnostic Software) Configuration and diagnostics interface RS-232 Transmission rate 38.4 kBaud Data interface RS-422 Transmission rate ≤ 500 kBaud Safe SICK device communication via EFI Transmission rate ≤ 500 kBaud Cable length ≤ 50 m Conductor cross-section 0.22 mm² Fieldbus, industrial network 1) Freely programmable, e.g., external device monitoring input, reset input, contamination warning, reset required. 2) Availability depends on the configuration of the universal I/Os. 3) 2+1; additional input is only available if reset and reset required are not being used. 4) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise three. 5) Two of the static swichting signals can be used either as dynamic or as static switching signals. 6) Freely programmable, e.g. warning field, contamination, reset required. 7) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems. 2017-05-23 16:45:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3

A B C D E F H I J K L M N O P Q R S T S30B-3011GB | S300 Expert SAFETY LASER SCANNERS Integration via EFI gateways CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 7) 1) Freely programmable, e.g., external device monitoring input, reset input, contamination warning, reset required. 2) Availability depends on the configuration of the universal I/Os. 3) 2+1; additional input is only available if reset and reset required are not being used. 4) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise three. 5) Two of the static swichting signals can be used either as dynamic or as static switching signals. 6) Freely programmable, e.g. warning field, contamination, reset required. 7) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems. Electrical data Protection class III (EN 50178, EN 60950) Supply voltage Vs 24 V DC (16.8 V DC ... 30 V DC) Power consumption ≤ 0.33 A 1) ≤ 1.7 A 2) Outputs Safety outputs (OSSD) 2 x 250 mA Diagnostic outputs 3 x 100 mA 3) 1) At 24 V DC without output load. 2) At 24 V DC including maximum output load. 3) Freely programmable, e.g. warning field, contamination, reset required. Mechanical data Dimensions (W x H x D) 102 mm x 152 mm x 106 mm Weight 1.2 kg Housing material Aluminum die cast Housing color RAL 1021 (yellow) Optics cover material Polycarbonat Optics cover surface finish Outside with scratch-resistant coating Ambient data Enclosure rating IP65 (EN 60529) Ambient operating temperature –10 °C ... +50 °C Storage temperature –25 °C ... +50 °C Vibration resistance 5 g, 10 Hz ... 150 Hz (IEC 61496-1, IEC 61496-3) Shock resistance 10 g, 16 ms (IEC 61496-1, IEC 61496-3) Other information Type of light Pulsed laser diode Wave length 905 nm Detectable remission 1.8 % ... > 1,000 %, reflectors Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)

4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

S30B-3011GB | S300 Expert SAFETY LASER SCANNERS Dimensional drawing (Dimensions in mm (inch)) Laser scanner (0.94) 25 (0.98) 79.3 (3.12) 106 (4.17) 54.5 (2.15) M5 x 7.5 10.5 (0.41) 102 (4.02) Ø 94 (3.70) 152 (5.98) 116 (4.57) 79.3 (3.12) 36.5 (1.44) 73 (2.87) 2017-05-23 16:45:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5

A B C D E F H I J K L M N O P Q R S T S30B-3011GB | S300 Expert SAFETY LASER SCANNERS Origin of scan plane Max. 200 (7.87) 74.7 (2.94) 69.7 (2.74) 59.7 (2.35) 23.8 (0.94) 36.4 (1.43) 116 (4.57) 54.5 (2.15) 106 (4.17) 126 (4.96) 146 (5.75) 130 (5.12) 73 (2.87) 270° Connection diagram S300 Expert with S300 Expert in host/guest connection with relays/contactors S300 Expert FE S300 Expert FE K1 K2 H8.1 H2.1 H2.2H8.2K3 K4 +24 V FE 0 V C2 A1 A2 B1 B2 k2 k1 k4 k3 x 2 x 2 z2 k2 E112699/00/2014-03-06 S300 Expert with S300 Expert in host/guest connection with relays/contactors Operating mode: with external device monitoring and without restart interlock Static protective field switching using the control inputs A, B and C The protective fields affect the related OSSDs on host or guest Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account.

6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

S30B-3011GB | S300 Expert SAFETY LASER SCANNERS Recommended accessories Other models and accessories www.sick.com/S300_Expert Brief description Type Part no. Mounting brackets and plates 1 piece, mounting bracket for rear mounting on wall or machine Mounting kit 1a 2034324 1 piece, mounting bracket for rear mounting on wall or machine with protection of op- tics hood Mounting kit 1b 2034325 1 piece, mounting bracket, adjustable lateral axis, only in conjunction with mounting kit 1a (2034324) or 1b (2034325) Mounting kit 2 2039302 1 piece, mounting plate, adjustable longitudinal axis, only in conjunction with mount- ing kit 2 (2039302) Mounting kit 3 2039303 Plug connectors and cables Head A: cable Head B: cable Cable: PVC, unshielded On 100 m reel Connecting cable 6030795 Head A: cable Head B: cable Cable: PVC, shielded Fitting for EFI connections EFI connecting cable 6029448 Head A: male connector, M8, 4-pin, straight Head B: male connector, USB-A, straight Cable: PVC, unshielded, 2 m DSL-8U04G02M025KM1 6034574 Head A: male connector, M8, 4-pin, straight Head B: male connector, USB-A, straight Cable: PVC, unshielded, 10 m DSL-8U04G10M025KM1 6034575 Head A: system plug Cable: without cable Not for use of incremental encoders, integrated configuration storage SX0B-A0000G 2032807 Head A: system plug Cable: without cable For use of incremental encoders, integrated configuration storage SX0B-A0000J 2032856 Head A: system plug Cable: pre-assembled, For use of incremental encoders, integrated configuration stor- age, PVC, unshielded, 5 m SX0B-B1105J 2032857 Head A: system plug Cable: pre-assembled, For use of incremental encoders, integrated configuration stor- age, PVC, unshielded, 10 m SX0B-B1110J 2032858 Head A: system plug Cable: pre-assembled, Not for use of incremental encoders, integrated configuration storage, PVC, unshielded, 5 m SX0B-B1505G 2034264 Head A: system plug Cable: pre-assembled, Not for use of incremental encoders, integrated configuration storage, PVC, unshielded, 10 m SX0B-B1510G 2034265 2017-05-23 16:45:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 7

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com