CLV690-0000 SICK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 7

Technical content

A B C D E F H I J K L M N O P Q R S T CLV690-0000 | CLV69x BAR CODE SCANNERS

Ordering information

Type Part no. CLV690-0000 1056600 Other models and accessories www.sick.com/CLV69x Detailed technical data

Features

Connection type Depending on the cloning plug used Reading field Front Scanner design Line scanner Focus Auto focus (alternative: dynamic focus control) No. of distance configurations ≤ 8 Focus adjustment time ≤ 20 ms Focus trigger source Data interface / switching inputs Light source Visible red light (660 nm) MTBF 100,000 h Laser class 2 (IEC 60825-1 (2007-3), EN 60825-1 (2008-05)) Aperture angle ≤ 60° Scanning frequency 400 Hz ... 1,200 Hz Code resolution 0.25 mm ... 1 mm Reading distance 500 mm ... 2,100 mm 1) Heating No 1) For details see reading field diagram. Performance Bar code types Interleaved 2 of 5, all current code types, Codabar, Code 128, Code 39, Code 93, GS1-128 / EAN 128, UPC / GTIN / EAN Print ratio 2:1 ... 3:1 No. of codes per scan 1 ... 20 (Standard decoder) 1 ... 6 (SMART decoder) No. of codes per reading interval 1 ... 50 (auto-discriminating) No. of characters per reading interval 5,000 No. of multiple readings 1 ... 100

2 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-03-21 14:30:08

Subject to change without notice

CLV690-0000 | CLV69x BAR CODE SCANNERS Interfaces Ethernet TCP/IP ✔ Remark Only with cloning plug I/O, CAN IN/OUT or CAN Redundant Function Host, AUX Data transmission rate 10/100 MBit/s PROFINET ✔ Remark Only with cloning plug I/O, CAN IN/OUT or CAN Redundant Function PROFINET Dual Port (optional via external connection module CDF600-2) EtherNet/IP™ ✔ Remark Only with cloning plug I/O, CAN IN/OUT or CAN Redundant Data transmission rate 10/100 MBit/s Serial ✔, RS-232, RS-422, RS-485 Remark Only with cloning plug D-Sub and Ethernet Function Host, AUX (only RS-232) CAN ✔ Function SICK CAN sensor network (Master/Slave, Multiplexer/Server) Data transmission rate 20 kbit/s ... 1 Mbit/s PROFIBUS DP ✔ Type of fieldbus integration Optional over external fieldbus module CDF600-2 DeviceNet™ ✔ Type of fieldbus integration Optional via external connection module CDM + CMF Switching inputs 6 (“Sensor 1” ... “Sensor 6”) Switching outputs 4 (“Result 1” ... “Result 4”) Reading pulse Switching inputs, serial interface, auto pulse, CAN Optical indicators 6 LEDs (Ready, Result, laser, Data, CAN, LNK TX, Bar graph for displaying the reading rate per- centage (10 LEDs)) Operating elements 2 buttons Parameter storage Integrated in cloning plug Configuration software SOPAS ET Mechanics/electronics Electrical connection Depending on the cloning plug used Operating voltage 18 V DC ... 30 V DC Power consumption 15 W Housing Aluminum die cast Housing color Light blue (RAL 5012) Front screen Glass Enclosure rating IP65 (EN 60529/A1 (2002-02)) Electrical safety As per UL 60950-1 certification Weight 1,500 g Dimensions (L x W x H) 117 mm x 117 mm x 94 mm 2017-03-21 14:30:08 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 3

A B C D E F H I J K L M N O P Q R S T CLV690-0000 | CLV69x BAR CODE SCANNERS Ambient data Electromagnetic compatibility (EMC) EN 61000-6-4 (2007-01) + A1 (2011) EN 61000-6-2 (2005-08) Vibration resistance EN 60068-2-6 (2008-02) Shock resistance EN 60068-2-27 (2009-05) Ambient operating temperature 0 °C ... +40 °C Storage temperature –20 °C ... +70 °C Permissible relative humidity 90 %, Non-condensing Ambient light immunity 2,000 lx, on bar code Classifications ECl@ss 5.0 27280102 ECl@ss 5.1.4 27280102 ECl@ss 6.0 27280102 ECl@ss 6.2 27280102 ECl@ss 7.0 27280102 ECl@ss 8.0 27280102 ECl@ss 8.1 27280102 ECl@ss 9.0 27280102 ETIM 5.0 EC002550 ETIM 6.0 EC002550 UNSPSC 16.0901 43211701 Dimensional drawing (Dimensions in mm (inch)) 59 ( 2.32) 58 (2.28) 73.5 (2.89) (1.46) (1.18) 26.7 (1.05) (.47) (1.02) (1.22) 44.2 (1.74) 24.5 (.96) 32 (1.26) (.55) (1.69) (1.38) (.83) 1.3 (.05) Ready Read Diagn Ressult Teach-in Laser Auto-Setup Data Adjusting CAN User defined LINK TX [%] 100 116 (4.57) 1 (.04) 2 (.08) 57 (2.24) 64.5° 114 (4.49) 32. 32° max. Einschrasubtiefe 7 mm max. screw-in depth 7 mm ① M6 blind tapped holes, 7 mm deep (2 x), for mounting

4 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-03-21 14:30:08

Subject to change without notice

CLV690-0000 | CLV69x BAR CODE SCANNERS Reading field diagram a b c Reading field height in mm (inch) –200 (–7.87) 200 (7.87) –400 (–15.75) 400 (15.75) 600 (23.62) –600 (–23.62) 400 (15.75) 700 (27.56) 1,000 (39.37) 1,300 (51.18) 1,600 (62.99) 1,900 (74.8) 2,200 (86.61) Reading distance in mm (inch) Resolution a: 0.30 mm (11.8 mil) c: 0.50 mm (19.7 mil) b: 0.35 mm (13.8 mil) Recommended accessories Other models and accessories www.sick.com/CLV69x Brief description Type Part no. Terminal and alignment brackets Quick-action lock system, mounting hardware included Quick release 2016110 Mounting brackets and plates Simple mounting bracket Mounting bracket 2013824 Modules Connection device basic for connecting one sensor with 2 A fuse, 5 cable glands and RS-232 interface to sensor via M12, 17-pin female connector, all outputs available on screw/spring-loaded terminals. CDB650-204 1064114 Fieldbus proxy/gateway for connecting identification sensors to PROFIBUS-DP networks (PROFIBUS interface: 2 x M12, male connector/female connector, 5-pin) CDF600-2100 1058965 Fieldbus proxy/gateway for connecting one identification sensor to PROFINET-IO net- works (interface 2 x M12, female connector/female connector, 4-pin) CDF600-2200 1062460 Modular connection module for one sensor, 2 A fuse CDM420-0006 1058634 Plug connectors and cables Head A: female connector, M12, 17-pin, straight, A-coded Head B: male connector, M12, 17-pin, straight, A-coded Cable: Power, serial, CAN, digital I/Os, drag chain use, suitable for 2 A, suitable for re- frigeration, shielded, 2 m Connection cable (male connector - female connector) 6053230 2017-03-21 14:30:08 | Online data sheet Subject to change without notice IDENTIFICATION SOLUTIONS | SICK 5

A B C D E F H I J K L M N O P Q R S T CLV690-0000 | CLV69x BAR CODE SCANNERS Brief description Type Part no. Head A: female connector, M12, 17-pin, straight Head B: male connector, D-Sub-HD, 15-pin, straight Cable: Power, serial, CAN, digital I/Os, shielded, 2 m Connection cable (male connector - female connector) 2055419 Head A: female connector, M12, 17-pin, straight, A-coded Head B: male connector, M12, 17-pin, straight, A-coded Cable: Power, serial, CAN, digital I/Os, suitable for 2 A, drag chain use, shielded, 2 m Connection cable (male connector - female connector) 6052286 Head A: male connector, M12, 4-pin, straight, D-coded Head B: male connector, RJ45, 8-pin, straight Cable: Ethernet, drag chain use, PUR, shielded, 2 m SSL-2J04-G02ME 6034414 Head A: male connector, M12, 17-pin Male connector, M12, 5-pin Female connector, M12, 4-pin Cable: Power, Ethernet, serial, CAN Plug housing I/O, Ethernet Cloning plug 2062452 Head A: Female connector (AUX), M12, 5-pin Female connector, M12, 5-pin Male connector, M12, 5-pin Cable: Power, CAN Plug housing CAN IN/OUT Cloning plug 2062453 Head A: male connector, D-Sub-HD, 15-pin Female connector, D-Sub-HD, 15-pin Cable: Power, serial, CAN, digital I/Os Plug housing Cloning plug 2062450 Head A: male connector, M12, 5-pin Head B: female connector, M12, 5-pin Cable: Power, CAN, Ethernet Plug housing CAN IN/OUT Ethernet Cloning plug 2074708

6 IDENTIFICATION SOLUTIONS | SICK Online data sheet | 2017-03-21 14:30:08

Subject to change without notice

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com