SAS4-S012P3PS1T00 SICK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 9

Technical content

SWITCHING AUTOMATION LIGHT GRIDS

A B C D E F H I J K L M N O P Q R S T SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS

2 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-03-09 17:40:10

Subject to change without notice

Ordering information

Type Part no. SAS4-S012P3PS1T00 1047364 Other models and accessories www.sick.de/SLG Detailed technical data

Features

Technology Sender/receiver Minimum detectable object (MDO) Parallel beam, 45 mm Beam separation 40 mm Optical light exit Slim Number of beams ≥ 4 Detection height 120 mm Configuration Teach button with configuration software Cross beam/parallel beam Parallel beam active Output 1 Output 1 active, if light beam interrupted Automatic teach Automatic teach inactive Alignment aid Without alignment aid Muting function Muting function deactivated Performance Maximum range 4 m 1) Minimum range Parallel beam: ≥ 0 mm 2) Working range 3 m Response time Parallel beam ≥ 19 ms 1) No reserve for environmental issue and deterioration of the diode. 2) Aperture ± 10°. Interfaces Switching output 1 x PNP Inputs Teach-in input Connection type Short cable with connector M8, 4-pin

SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS 2016-03-09 17:40:10 | Online data sheet Subject to change without notice AUTOMATION LIGHT GRIDS | SICK 3 Mechanics/electronics Wave length Infrared light, 950 nm Supply voltage Vs DC24 V, ± 20 % 1) Power consumption sender ≥ 64 mA 2) Power consumption receiver ≥ 70 mA 2) 2) Ripple < 5 Vpp Output current Imax. ≤ 100 mA Output load capacitive 100 nF Output load inductive 1 H Initialization time 1 s Dimensions (W x H x D) 25 mm x 192.4 mm x 8 mm Housing material PMMA Indication LED Synchronization Optical Enclosure rating IP 65 Circuit protection UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse suppression Weight ≥ 20 g Switching frequency 500 kHz Aluminum stabilizer Without stabilizer 1) Limit values. 2) Without load. Ambient data Protection class III EMC EN 60947-5-2 Ambient temperature Operation: –25 °C ... +55 °C Storage: –25 °C ... +70 °C Ambient light immunity Direct: 100,000 lx 1) Indirect: 150,000 lx Vibration resistance 5 g, 10 Hz ... 55 Hz (IEC 68-2-6) Shock load 10 g / DIN EN 60068-2-29 / 16 ms 1) Sunlight.

A B C D E F H I J K L M N O P Q R S T SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS

4 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-03-09 17:40:10

Subject to change without notice Dimensional drawing (Dimensions in mm (inch)) Sxx-Sxxxxxxx1xxx DH = (n x RM) – RM RM 100 (3.94) 1.2 (0.05) 1.2 (0.05) 44.5 (1.75) 8.5 (0.33) 8.2 (0.32) Ø 9 (0.35) (0.98) 8.6 (0.34) Slim, without stabilizer Receiver Sender Sender ① First beam ② Last beam ③ Beam separation (RM) ④ Number of beams (n) ⑤ Detection height (DH) ⑥ Connection

SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS 2016-03-09 17:40:10 | Online data sheet Subject to change without notice AUTOMATION LIGHT GRIDS | SICK 5 Adjustments SAS, SGS, receiver, LED indication ON Q/ /c81 Func /c49 /c50 /c51 constantly shining out TEACH ① Supply voltage ② Active if teach-in button is pressed ③ No object in the light path Connection type and diagram SAS Sender Receiver Teach M Test M NC

A B C D E F H I J K L M N O P Q R S T SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS

6 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-03-09 17:40:10

Subject to change without notice Concept of operation SAS, SGS, SPL The light grid communicates via the light beams. A cable is not necessary for the optical synchronization. Optical synchronization

SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS 2016-03-09 17:40:10 | Online data sheet Subject to change without notice AUTOMATION LIGHT GRIDS | SICK 7 Muting 5) Invert second switching output Standard values 4) Pushbutton lock Auto-teach 3) Invert switching output Alignment aid 2) Q ON Q ON Press teach button > 5 s. The light grid switches into the configuration mode – menu item “cross beam/parallel beam”. The first green LED from top flashes. 1. Light grid in RUN mode, green LED “ON” illuminates, yellow LED “Q” illuminates. The other menu items in sequence of the menu setting of the light grid 4. Exit the configuration mode. 2. Cross or parallel beam set up. 1) 3. Go to the next menu item. Press teach button for 1 s to 5 s to switch to the next menu item (in this case “alignment aid”). oder 3 = Press teach button > 5 s, □ save parameters. 4 = Wait > 30 s, □ parameters not saved. Func Q ON > 5 s < 1 s 1 = Yellow LED on, □ “Crossed beam” active. 2 = Yellow LED off, □ “Parallel beam” active. Press teach button < 1 s to switch between the settings. Q ON Q ON 1 s ... 5 s > 5 s > 30 s active Q ON inactive Q ON Q Q ON Q Q ON active inactive Q ON Q ON AUTO TEACH AUTO TEACH active inactive Q ON Q ON active inactive Q ON Q ON active inactive Q ON Q ON Q ON MUTING MUTING Q ON If the teach button is pressed longer than 5 s, you switch into the configuration mode. In the configuration mode the menu items are indicated by the green LEDs. If the teach button is then pressed for < 1 s, the respective function is activated or reset (yellow LED on or off). If the teach button is pressed for 1 s to 5 s long, you switch to the next menu item. To exit the configuration mode, press the teach button for > 5 s or wait for 30 s. 1) Configure the light grid in a 3-way cross-beam or a parallel-oriented opera ting principle. The cross beam can be used to improve the resolution in the middle detection area. Objects up to a size of 25 mm can be detected. The response time increases. 2) The alignment aid is recommended for applications with high ranges. The signal st rength of the receiver is permanently displayed by four green alignment LEDs. Depending on the strength, the number of illuminated LEDs differ. When reception is strong, all four LEDs illuminate. The alignment aid must be deactivated again after alignment. 3) After commissioning (power on), the switching threshold is taught in automat ically. No object should be between the sender and receiver during this process. 4) With standard values “active” all parameters are reset to the delive ry state. 5) If a beam is interrupted permanently, it disappears after > 60 s, and the swi tching output Q 1 is enabled again. If a second switching output is present, it remains inactive.

A B C D E F H I J K L M N O P Q R S T SAS4-S012P3PS1T00 | SLG SWITCHING AUTOMATION LIGHT GRIDS

8 AUTOMATION LIGHT GRIDS | SICK Online data sheet | 2016-03-09 17:40:10

Subject to change without notice 1. Light grid in RUN mode, green LED “ON” illuminates, yellow LED “Q” illuminates. 3. Light grid in RUN mode, green LED “ON” illuminates, yellow LED “Q” illuminates. 2. Alignment aid is automatically activated for 10 s. The switching threshold is set. Func Q ON 1 s ... 5 s Q ON 1 = Optimum light reception. 2 = Light reception not optimized, ➜ align sensors. 3 = No light received, ➜ check light path. The light grid switches after 10 s automatically back into the RUN mode. Press the teach button for 1 s to 5 s. During the teach process the green LEDs illuminates sequentially. The red LED “Func” illuminates. Q Func ON Q ON Q ON Func Func Funktionsprinzip Slim & Flat 1 2 ① Slim model = light emission on narrow side ② Flat model = light emission on broad side Recommended accessories Other models and accessories www.sick.de/SLG Brief description Type Part no. Mounting brackets and mounting plates Mounting bracket for light grids up to a monitoring height of 600 mm, mounting on the face sides, 2x BEF-SLG1, 2x BEF-SLG2 BEF-SLG-SET1 2055427 Plug connectors and cables Head A: female connector, M8, 4-pin, straight Head B: cable Cable: PVC, unshielded, 2 m DOL-0804-G02M 6009870

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com