S3000 Cold Store S31A-7011CA, Online data sheet

Document overview

  • Manufacturer or author: SICK AG | Subject to change without notice
  • PDF pages: 9

Technical content

A B C D E F H I J K L M N O P Q R S T S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS

Ordering information

Type Part no. S31A-7011CA 1041648 Other models and accessories www.sick.com/S3000_Cold_Store Detailed technical data

Features

Protective field range 7 m Warning field range 49 m (20 m at 20 % reflectivity) Distance measuring range 49 m Number of simultaneously monitored pro- tective fields ≤ 4 1) Type of field set Triple field sets, dual field sets Number of field sets 4 Number of fields 12 Number of monitoring cases 4 Scanning angle 180° Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm, 150 mm Angular resolution 0.5°, 0.25°, depending on range and resolution Response time 120 ms 2) Protective field supplement 100 mm Number of multiple samplings 2 ... 16, configurable Delay of automatic reset 2 s ... 60 s, configurable 1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway. 2) Depending on basic response time and multiple sampling. Safety-related parameters Type Type 3 (IEC 61496) Safety integrity level SIL2 (IEC 61508) SILCL2 (EN 62061) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 8.0 x 10-8 (EN ISO 13849) TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state.

2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS Functions Multiple sampling ✔ Monitoring case switching ✔ Simultaneous monitoring ✔ Static protective field switching ✔ Contour as a reference ✔ Safe SICK device communication via EFI ✔ Interfaces Connection type System plug Inputs Static control inputs 2 Static control inputs with EFI 5 1) Outputs OSSD pairs 1 Diagnostic outputs 2 2) Configuration method PC with CDS (Configuration and Diagnostic Software) Configuration and diagnostics interface RS-232 Transmission rate 9.6 kBaud, 19.2 kBaud, 38.4 kBaud Safe SICK device communication via EFI Transmission rate ≤ 500 kBaud Cable length ≤ 50 m Conductor cross-section 0.34 mm² Fieldbus, industrial network Integration via EFI gateways CANopen, Ethernet, PROFIBUS DP, PROFIBUS PROFIsafe, PROFINET PROFIsafe 3) 1) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise two. 2) Freely programmable, e.g. warning field, contamination, reset required. 3) For a suitable EFI-gateway see modules and gateways in the accessory section of connection systems. Electrical data Protection class II (EN 50178) Supply voltage Vs Power consumption Scanner ≤ 0.8 A 1) ≤ 2.3 A 2) Heating ≤ 6 A, cyclical Outputs Safety outputs (OSSD) 2 x 500 mA Diagnostic outputs 2 x 100 mA 3) 1) At 24 V DC without output load. 2) At 24 V DC including maximum output load. 3) Freely programmable, e.g. warning field, contamination, reset required. 2017-05-23 16:45:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3

A B C D E F H I J K L M N O P Q R S T S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS Mechanical data Dimensions (W x H x D) 351 mm x 265 mm x 221 mm Weight 9 kg Material Back panel, plug Aluminum die cast Cover Polyurethane Housing color RAL 1021 (yellow) Front screen material Polycarbonat Front screen surface finish Outside with scratch-resistant coating Ambient data Enclosure rating IP65 (EN 60529) IP67 (EN 60529) Ambient operating temperature –30 °C ... +50 °C Storage temperature –30 °C ... +50 °C Vibration resistance 5 g, 10 Hz ... 150 Hz (IEC 61496-1, IEC 61496-3) Shock resistance 10 g, 16 ms (IEC 61496-1, IEC 61496-3) Other information Type of light Pulsed laser diode Wave length 905 nm Detectable remission 1.8 % ... > 1,000 %, reflectors Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)

4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS Dimensional drawing (Dimensions in mm (inch)) Desiccant cartridge Beam exit height Connection plug 351 (13.82) 175 (6.89) 265 (10.43) 82.5 (3.25) 82.5 (3.25) 81.5 (3.21) (2.05) 20.5 (0.81) (1.81) 175 (6.89) 79.5 (3.13) 79.5 (3.13) (2.09) (0.08) 20.5 (0.81) 99.5 (3.92) 123 (4.84) 194.5 (7.66) 31.5 (1.24) 55.5 (2.19) (2.64) (0.16) (0.16) (0.55) 2017-05-23 16:45:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5

A B C D E F H I J K L M N O P Q R S T S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS Connection diagram Protective field switching between two S3000 with static inputs

0 V DC Scanner

+24 V DC Scanner K3 H2 K4 k1 k3 k4 k2 z1 z2 x1 y1 k1 k2 x1 y1 x2 y2 +24 V DC Heating

0 V DC Heating

S3000 Cold Store with S3000 Cold Store in conjunction with relays/contactors Protective field switching by means of control input A and control input B on separate OSSD pairs (simultaneous monitoring) Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. S3000 Cold Store in conjunction with relays/contactors Protective field switching by means of control inputs A and B Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account.

6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS Protective field switching with two static inputs +24 V DC Scanner +24 V DC Heating z z x y x y E112711/00/2014-03-06 S3000 Cold Store S3000 Cold Store with S3000 Cold Store in conjunction with relays/contactors Protective field switching by means of control input A and control input B on separate OSSD pairs (simultaneous monitoring) Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. S3000 Cold Store in conjunction with relays/contactors Protective field switching by means of control inputs A and B Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. 2017-05-23 16:45:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 7

A B C D E F H I J K L M N O P Q R S T S31A-7011CA | S3000 Cold Store SAFETY LASER SCANNERS Recommended accessories Other models and accessories www.sick.com/S3000_Cold_Store Brief description Type Part no. Mounting brackets and plates Mounting kit for wall-mounting (adjustment bracket), steel, zinc coated Mounting kit 2018303 Plug connectors and cables Head A: cable Head B: cable Cable: PVC, unshielded Connecting cable 6025729 Head A: cable Head B: cable Cable: PVC, shielded Fitting for EFI connections EFI connecting cable 6029448 Head A: female connector, 16-pin Head B: - Cable: unshielded 16-pin female connector 2018301 Cable: RS-232, RS-422, unshielded, 5 m, configuration cable pre-assembled for RS-232, for the connection of PCs/power supply Service cable 2019561 Drying agent cartridges Dry cartridge Drying agent car- tridge with screw thread M36 x 1.5 5306179

8 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-23 16:45:04

Subject to change without notice

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com