106-P30-5A E-T-A | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 5
Technical content
www.e-t-a.de 2331 104/105/106-... Thermal circuit breakers
Description
Single pole thermal circuit breaker in miniaturised design. A positively trip-free snap action mechanism ensures a reliable switching behaviour. They meet the requirements of the circuit breaker standard EN 60934 (IEC 60934): R-Type, TO. For higher current ratings in a similar design please see our 1140 version. The 106 version combined with a C14 appliance inlet is also available as a ready-for-use power entry module (optionally with or without line filter). Hand tools, domestic appliances, overcurrent protection of PCB conductor paths, marine vehicles, mobile homes Approval authority Standard Rated voltage Current rating range VDE EN 60934 AC 240 V DC 48 V
0.05 A … 8 A
0.05 A … 10 A
0.05 A…10 A
CSA C22.2 No 235 AC 250 V DC 48 V
0.05 A…8 A
For detailed technical information please see www.e-t-a.de/ti_en Rated voltage AC 240 V, DC 48 V Current rating range 0.05 ... 10 A Typical life 0.05 ... 5 A 6 ... 8 A 10 A 1,000 cycles at 2 x IN, inductive DC 28 V: 3,000 cycles at 2 x IN, inductive 500 cycles at 2 x IN, inductive 50 cycles at 2 x I N, inductive Ambient temperature -20 ... 60 °C (T 60) Insulation coordination (IEC 60664) 2.5 kV /2 reinforced insulation at operating area Dielectric strength Actuating area Test voltage AC 3,000 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity Icn 0.05 ... 8 A 6 x IN (AC) 0.05 ... 10 A 6 x IN (DC) Rupture capacity IN UN S.C. (UL 1077) 0.05 ... 10 A AC 250 V 2000 A, C1 0.05 ... 10 A DC 48 V 200 A, C1 Degree of protection (IEC 60529) Operating area IP40 IP00 terminal area Vibration 10 g (57-500 Hz), ± 0.76 mm (10-57 Hz), Test to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock resistance 25 g (11 ms) Test to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, Test to IEC 60068-2-11, test Ka Humidity 240 hrs 95 % RH, test acc. to IEC 60068-2-78, Test Cab Mass approx. 10 g Compliance Preferred types Preferred ratings (A) 0.5 0.8 1 1.2 1.5 2 3 4 5 6 8 10 106-P10- x x x x x x x x x x x x 106-P30- x x x x x x x x x x x x Preferred types
104/105/106-... Thermal circuit breakers www.e-t-a.de 2331 Ordering number code Type No.
104 PCB mounting type (-PR)
or mounting type (-P30/-P10)
105 Snap-in panel mounting
106 Threadneck mounting with screw-in hexagonal
and plastic knurled nut(1) 106-M2 Threadneck mounting with large lug and screw-in hexagonal and plastic knurled nut Terminal design P10 Blade terminal 6.3 x 0.8 mm (IEC 61210) P30 Blade terminal 2.8 x 0.8 mm (IEC 61210) PR PR Soldering pins for horizontal PCB mounting (104 version only) PR3 PR3 Soldering pins for vertical PCB mounting (104 version only) Current rating range 0.05 ... 10 A (1) Use this version for configuration with XR38 power entry module Please observe our minimum ordering quantities. Current ratings and internal resistance values Current rating (A) Internal resistance (Ω) Current rating (A) Internal resistance (Ω) 0.05 285 1.8 0.28 0.08 134 2 0.25 0.1 81 2.5 0.18 0.2 22 3 0.11 0.3 8.7 3.5 0.076 0.4 5.5 4 0.067 0.5 3.3 4.5 0.051 0.6 2.45 5 ≤ 0.05 0.7 1.6 6 ≤ 0.05 0.8 1.45 7 ≤ 0.05 1 0.9 8 ≤ 0.05 1.2 0.6 10 ≤ 0.05 1.5 0.4 Dimensions 6.5 ±0.5 ø 4 9.5 ±0.5 27.5 4.5 max. 3 1.2 3.5 18.5 9.8 104 - PR 0.05...6 A 104 - PR 0.05...6 A ON OFF 104 - PR 7...10 A 104 - PR 7...10 A Offset intended for mounting ø1.5 9.8 18.5 0.9 ø1.5 9.8 0.9 104-PR Dimensions PCB drilling hole diagram
www.e-t-a.de 2331 104/105/106-... Thermal circuit breakers 104/105/106-... Thermal circuit breakers Dimensions Dimensions 104 - PR3 0.05...6 A 104 - PR3 0.05...6 A 104 - PR3 7...10 A 104 - PR3 7...10 A 104-PR3 Dimensions PCB drilling hole diagram 1.24 15.45 0.8 ø 4 ø 7 6.5 ±0.5 9.5 ±0.5 29.6 27.6 max. 3 6.5 5.2 3.9 1.2 2.2 6.2 7.2 ON OFF Drilling hole for M2 mounting screw usable depth 4.5 mm 2.2 3.9 Drilling hole without contacting (for adjustable screw) Drilling hole without contacting (for adjustable screw) ø1.5 15.45 7.2 ø2.3 ø1.5 5.2 7.2 ø2.3 104 - P30 0.05...6 A 104 - P30 7...10 A 104-P30 6.5 Drilling hole for M2 mounting screw usable depth 4.5 mm 6.5 ±0.5 ø 4 ø 7 9.5 ±0.5 27.5 29.5 1.2 max. 3 ø2.2 ø 7.3 9.7 6.5 OFF ON Installation dimensions Blade terminal 2.8 x 0.8 mm according to IEC 61210 15.45 7.9 3.2 d Blade terminal 2.8 x 0.8 mm according to IEC 61210 27.6 29.6 Cut-out dimensions b a 105-P30 7...10 A 0.8 1.0 1.5 2-3 21.9 22.1 22.2 b 11.3+0.3 max. 3 9.5 ON6.5 OFF 1.2 9.5 d a 105-P30 15.45 7.9
104/105/106-... Thermal circuit breakers www.e-t-a.de 2331 Dimensions 106-P30 7...10 A SW14 max. 3 ON OFF 3/8-27UNS-2A tightening torque max. 0.8 Nm 0.7 727.69.5 1.2 Blade terminals 2.8 x 0.8 mm according to IEC 61210 15.7 8.8 Mounting hole 9.6-0.07 8.9-0.1 13.5 10.5 106-P30 Mounting hole ø9.6-0.07 8.9-0.01 106-M2 3/8-27UNS-2A tightening torque max. 0.8 Nm 15.45 7.9 Terminal types Blade terminal 6.3 x 0.8 mm according to IEC 61210 6.3 Polarizing tooth 104/105/106-P10 15.45 7.9 Mounting area Operating area 8Mounting area Operating area 104-P10 104-P30 105-… 106-… Mounting area Operating area Installation drawing Schematic diagrams Types 104 105 106
www.e-t-a.de 2331 104/105/106-... Thermal circuit breakers 104/105/106-... Thermal circuit breakers Time/current characteristics The time/current characteristic depends on the ambient temperature. In order to eliminate nuisance tripping, please multiply the current rating with a tem- perature factor (see Technical Information chapter) Ambient temperature [°C] -20 -10 0 +23 +40 +50 +60 12 46 81 02 04 0 Trip time in seconds … times rated current 0.05 - 6 A 7 - 10 A 10000 1000 100 0.1 0.8 1.4 Ambient temperature 23 °C Accessories Water splash cover (transparent)/ knurled nut assembly (type 106-... only) X 201 285 01 (IP64) ø15 3 3/8-27UNS-2B Knurled nut 3/8", plastic (standard) Y 307 117 02 3/8-27UNS-2B SW14 Hex nut 3/8", nickel-plated brass Y 300 192 01 2.5 14.5 All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of technical improvement. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Ordering codes of the products may differ from their marking.