A B C D E F H I J K L M N O P Q R S T WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS Illustration may differ

Ordering information

Type Part no. WL24-2V530S06 1027613 Other models and accessories www.sick.com/W24-2_Ex Detailed technical data

Features

Sensor/ detection principle Photoelectric retro-reflective sensor Dimensions (W x H x D) 38 mm x 154.5 mm x 77 mm Housing design (light emission) Rectangular Sensing range max. 0 m ... 22 m 1) Sensing range 0 m ... 15 m 1) Type of light Visible red light Light source LED 2) Light spot size (distance) Ø 250 mm (15 m) Adjustment Potentiometer Alarm output ✔ 1) Reflector PL80A. 2) Average service life: 100,000 h at TU = +25 °C. Communication interface Communication interface - Mechanics/electronics Supply voltage 10 V DC ... 30 V DC 1) Ripple < 5 Vpp 2) 1) Limit values. 2) May not exceed or fall below Uv tolerances. 3) Without load. 4) Signal transit time with resistive load. 5) With light/dark ratio 1:1. 6) A = VS connections reverse-polarity protected. 7) C = interference suppression. 8) D = outputs overcurrent and short-circuit protected. 9) Reference voltage: 50 V DC.

2 PHOTOELECTRIC SENSORS | SICK Online data sheet | 2017-11-09 11:23:44

Subject to change without notice

WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS Power consumption ≤ 50 mA 3) Output type NPN PNP Switching mode Light/dark switching Light/dark switching Switching mode selector Selectable via PNP/NPN selector, selectable via light/dark selector Output current Imax. 100 mA Response time ≤ 500 µs 4) Switching frequency ± 1,000 Hz 5) Connection type Male connector M12, 5-pin Circuit protection A 6) C 7) D 8) Protection class II 9) Weight 800 g Polarisation filter ✔ Special device ✔ Housing material Metal, Zinc diecast Enclosure rating IP67 Test input sender off TE to 0 V Certificate (IECEx) IECEx PTB 14.0031 ATEX marking EX II 3G EX nA op is IIB T4 Gc X EX II 3D EX tc IIIB T135°C Dc IP67 X According to directive 2014/34/EX/EU Ex area category 3D, 3G Ambient operating temperature –20 °C ... +50 °C Ambient storage temperature –40 °C ... +75 °C 1) Limit values. 2) May not exceed or fall below Uv tolerances. 3) Without load. 4) Signal transit time with resistive load. 5) With light/dark ratio 1:1. 6) A = VS connections reverse-polarity protected. 7) C = interference suppression. 8) D = outputs overcurrent and short-circuit protected. 9) Reference voltage: 50 V DC. Classifications ECl@ss 5.0 27270902 ECl@ss 5.1.4 27270902 ECl@ss 6.0 27270902 ECl@ss 6.2 27270902 ECl@ss 7.0 27270902 ECl@ss 8.0 27270902 ECl@ss 8.1 27270902 ECl@ss 9.0 27270902 2017-11-09 11:23:44 | Online data sheet Subject to change without notice PHOTOELECTRIC SENSORS | SICK 3

A B C D E F H I J K L M N O P Q R S T WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS ETIM 5.0 EC002717 ETIM 6.0 EC002717 UNSPSC 16.0901 39121528 Adjustments possible PNP NPN D H /c54 /c55 /c56 /c57 ② LED signal strength indicator ⑦ Sensitivity control ⑧ Light/dark selector ⑨ NPN/PNP changeover switch Connection diagram Cd-150 + (L+) Test - (M) BN WH BU Q/ QBK 4 AlarmGY 5

4 PHOTOELECTRIC SENSORS | SICK Online data sheet | 2017-11-09 11:23:44

Subject to change without notice

WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS Characteristic curve WL24-2 100 Sensing range Sensing range typ. max. m (feet) (16.40) (32.81) (49.21) (65.62) (82.02) Distance in m (feet) ① Reflector PL80A ② Reflector PL50A ③ Reflector PL40A ④ Reflector PL30A ⑤ Reflector PL20A ⑥ Reflective tape Diamond Grade ⑦ Reflector C110A Sensing range diagram WL24-2 0 4 (13.12) (26.25) (39.37) (52.49) (65.62) (78.74) /c53 /c52 /c51 /c50 /c49 Distance in m (feet) Sensing range 11 16 15 22 Sensing range max. 7 10 0.03 7 14 20 11 16 0.03 0.03 0.03 10 13 0.15 7 10 0.03 7 10 0.03 ① Reflector PL80A ② Reflector PL50A ③ Reflector PL40A ④ Reflector PL30A ⑤ Reflector PL20A ⑥ Reflective tape Diamond Grade ⑦ Reflector C110A 2017-11-09 11:23:44 | Online data sheet Subject to change without notice PHOTOELECTRIC SENSORS | SICK 5

A B C D E F H I J K L M N O P Q R S T WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS Dimensional drawing (Dimensions in mm (inch)) 73.5 (2.89) 154.5 (6.08) 88.4 (3.48) 34.8 (1.37) 77 (3.03) 148.4 (5.84) 38 (1.50) (0.55) 98 (3.86) 34 (1.34) ① LED signal strength indicator ② Center of optical axis, sender ③ Center of optical axis, receiver ④ Connection ⑤ Fixing hole for clamb holder Recommended accessories Other models and accessories www.sick.com/W24-2_Ex Brief description Type Part no. Universal bar clamp systems Universal bar clamp for mounting bars with 12 mm diameter, Zinc diecast, without mounting plate and screws BEF-KHS-KH3 5322626 Plate N03 for universal clamp bracket, zinc coated, Zinc plated steel (sheet), Zinc die cast (clamping bracket), Universal clamp (5322626), mounting hardware BEF-KHS-N03 2051609 Plate N04 for universal clamp, steel, Zinc plated steel (sheet), Zinc die cast (clamping bracket), Universal clamp (5322626), mounting hardware BEF-KHS-N04 2051610 Device protection (mechanical) Water cooling plate BEF-KP-W24 2015071

6 PHOTOELECTRIC SENSORS | SICK Online data sheet | 2017-11-09 11:23:44

Subject to change without notice

WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS Brief description Type Part no. Dust protection tube, air-purged, Aluminum (anodised), mounting hardware included OBS-W24 2015069 Weather hood for universal clamp bracket, steel, zinc coated, mounting hardware in- cluded OBW-KHS-M01 2023240 OBW-W24 2015070 Weather hood, Aluminum (anodised), mounting hardware included WSG1-01 1018470 Mounting brackets and plates Mounting bracket, small, Stainless steel, without mounting hardware BEF-WK-W24 4027532 Mounting bracket, Stainless steel (1.4301), mounting hardware included BEF-WN-W24 2015248 Modules and gateways NAMUR isolatig amplifier, Cable fault detection, Switching outputs: 2 NO relay (1 per channel), Supply voltage: 24 V ... 230 V, Voltage type: AC/DC EN2-2EX1 6041096 NAMUR isolatig amplifier, Cable fault detection, Switching outputs: 2 NO relay (1 per channel), Supply voltage: 19,2 V ... 30 V, Voltage type: DC EN2-2EX3 6041095 Alignment aids Adapter for alignment aid AR60 Adapter AR60 for W24-2 4032976 Reflectors Rectangular, screw connection, 47 mm x 47 mm, PMMA/ABS, Screw-on, 2 hole mount- ing P250 5304812 Rectangular, screw connection, 38 mm x 15 mm, PMMA/ABS, Screw-on, 2 hole mount- ing PL20A 1012719 Rectangular, screw connection, 56 mm x 28 mm, PMMA/ABS, Screw-on, 2 hole mount- ing PL30A 1002314 Rectangular, screw connection, 37 mm x 56 mm, PMMA/ABS, Screw-on, 2 hole mount- ing PL40A 1012720 Rectangular, screw connection, 80 mm x 80 mm, PMMA/ABS, Screw-on, 2 hole mount- ing PL80A 1003865 Self-adhesive REF-IRF-56 5314244 2017-11-09 11:23:44 | Online data sheet Subject to change without notice PHOTOELECTRIC SENSORS | SICK 7

A B C D E F H I J K L M N O P Q R S T WL24-2V530S06 | W24-2 Ex PHOTOELECTRIC SENSORS Brief description Type Part no. Round, screw connection, PMMA/ABS, Center hole mounting, screw-on C110A 5304549

8 PHOTOELECTRIC SENSORS | SICK Online data sheet | 2017-11-09 11:23:44

Subject to change without notice

SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com