1000 MURATA-PS | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
KMP_1000C_F01 Page 1 of 3
1000 Series
www.murata.com www.murata.com For full details go to https://www.murata.com/en- global/products/power/rohs SELECTION GUIDE1 Order Code Turns Ratio ±2% Min. Primary nductance Min. Primary Constant, ET Max. Leakage Inductance Max. Interwinding Capacitance Max. DC Resistance Primary Winding Max. DC Resistance Secondary 1 winding Max. DC Resistance Secondary 2 winding Isolation Voltage Pin Connection Style Mechanical Dimensions Recommended Alternative mH Vμs μH pF Ω Ω Ω Vrms 1001C 1:1 3.0 200 32 23 1.2 1.0 - 2000 A 2 1002C 1:1:1 3.0 200 30 51 1.4 1.3 1.7 2000 B 1 1003C 2:1:1 12 400 62 58 5.0 2.0 3.0 2000 B 1 1013C 1:1:1 3.0 200 3 585 2.0 2.0 2.0 500V DC B1 1016C 1:1 3.0 200 22 23 1.2 1.0 - 3500 A 2 1017C 1:1 0.8 130 5 20 0.4 0.3 - 4000 A 2 1025C 2:1:1 24 570 90 83 8.7 3.5 5.2 2000 B 1 1007C 1:1:1 7.4 310 35 55 2.9 2.5 3.4 2000 B 1 Contact Murata 1009C 1:1:1 22 550 85 71 13.4 11 15.8 2000 B 1 Contact Murata 1024C 1.2CT:1CT 8.8 340 60 25 2.5 2.5 - 2000 C 1 Contact Murata 1026C 1:1:1 6.0 285 30 62 4.0 4.0 4.9 2000 B 1 Contact Murata 1082C 100:1 6.1 280 - 6 1.1 0.1 - 2000 A 2 Contact Murata ABSOLUTE MAXIMUM RATINGS Operating free air temperature range 0°C to 70°C Storage temperature range -60°C to 125°C SOLDERING INFORMATION1 Peak wave solder temperature 260˚C for 10 seconds Wave solder Wave solder profile not to exceed the profile recommended in IEC 61760-1 Section 6.1.3. Pin finish Matte tin TUBE DIMENSIONS 1 For further information, please visit www.murata-ps.com/rohs All specifications typical at TA=25°C.
FEATURES
RoHS compliant UL 94V-0 package material Isolation to 4kVrms Compact footprint PCB mounting Backward compatible with Sn/Pb soldering systems
DESCRIPTION
The 1000 series are intended for wideband and pulse operations. They are also suitable for signal isolation and use in small isolated power supplies. The compact footprint makes them ideal for applications where space is at a premium. 7.00 (0.276) 24.00 (0.945) 8.00 (0.315) 17.00 (0.669) All dimensions in mm (inches). Tube length: 480±2mm (18.9±0.08) NRND Tube quantity: 30
KMP_1000C_F01 Page 2 of 3 www.murata.com MECHANICAL DIMENSIONSPIN CONNECTIONS (TOP VIEW) 15.06 (0.593) 15.06 (0.593) 15.75±0.50 (0.620±0.02)20.5 (0.807) 5.08 (0.20) 5.08 (0.20) 10.16 (0.40) Ø0.71±0.05 (Ø0.028±0.002) 1003C YYWW 15.06 (0.593) 15.06 (0.593) 15.75±0.50 (0.620±0.02)20.5 (0.807) 10.16 (0.40) 10.16 (0.40) Ø0.71±0.05 (Ø0.028±0.002) 1001C YYWW 122 Pri Sec Pri S2 S1 PriSec A B All dimensions in mm (inches). C TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isola- tion Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. All products in this series are 100% production tested at their stated isolation voltage. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the insulative materials used. Such materials are susceptible to chemical degradation when subject to very high applied voltages. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely re- quired, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognised parts rated for better than functional isolation where wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Package weight: 8.0g Typ.
KMP_1000C_F01 Page 3 of 3 www.murata.com Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2022 Murata Power Solutions (Milton Keynes) Ltd. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard prod- ucts for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to:
- Aircraft equipment
- Aerospace equipment
- Undersea equipment
- Power plant control equipment
- Medical equipment
- Transportation equipment (automobiles, trains, ships, etc.)
- Traffic signal equipment
- Disaster prevention / crime prevention equipment
- Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any applica- tion or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, moni- tor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions.