S30A-6011DA SICK | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
A B C D E F H I J K L M N O P Q R S T S30A-6011DA | S3000 Professional SAFETY LASER SCANNERS system plug not supplied with delivery
Ordering information
Type Part no. S30A-6011DA 1019600 The system plug has to be ordered separately. For details, see “Accessories”. Other models and accessories www.sick.com/S3000_Professional Detailed technical data
Features
Protective field range 5.5 m Warning field range 49 m (20 m at 20 % reflectivity) Distance measuring range 49 m Number of simultaneously monitored pro- tective fields ≤ 4 1) Type of field set Triple field sets, dual field sets Number of field sets 8 Number of fields 24 Number of monitoring cases 16 Scanning angle 190° Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm, 150 mm Angular resolution 0.5°, 0.25°, depending on range and resolution Response time 60 ms 2) Protective field supplement 100 mm Number of multiple samplings 2 ... 16, configurable Delay of automatic reset 2 s ... 60 s, configurable 1) If more than one protective field is monitored simultaneously, then the safe output signals must be routed to safe outputs of a Flexi Soft safety controller, or via a safe EFI gateway. 2) Depending on basic response time and multiple sampling. Safety-related parameters Type Type 3 (IEC 61496) Safety integrity level SIL2 (IEC 61508) SILCL2 (EN 62061) Category Category 3 (EN ISO 13849) Performance level PL d (EN ISO 13849) PFHD (mean probability of a dangerous fail- ure per hour) 8.0 x 10-8 (EN ISO 13849)
2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-30 12:10:04
Subject to change without notice
S30A-6011DA | S3000 Professional SAFETY LASER SCANNERS TM (mission time) 20 years (EN ISO 13849) Safe state in the event of a fault At least one OSSD is in the OFF state. Functions Restart interlock ✔ External device monitoring (EDM) ✔ Multiple sampling ✔ Monitoring case switching ✔ Simultaneous monitoring ✔ Static protective field switching ✔ Dynamic protective field switching ✔ Contour as a reference ✔ Integrated configuration memory ✔ Measured data output ✔ Safe SICK device communication via EFI ✔ Electrical data Protection class II (EN 50178) Power consumption ≤ 0.8 A 1) ≤ 2.3 A 2) Outputs Safety outputs (OSSD) 2 x 500 mA Diagnostic outputs 3 x 100 mA 3) 1) At 24 V DC without output load. 2) At 24 V DC including maximum output load. 3) Freely programmable, e.g. warning field, contamination, reset required. Mechanical data Dimensions (W x H x D) 155 mm x 185 mm x 160 mm Weight 3.3 kg Housing material Aluminum die cast Housing color RAL 1021 (yellow) Front screen material Polycarbonat Front screen surface finish Outside with scratch-resistant coating Ambient data Enclosure rating IP65 (EN 60529) Ambient operating temperature –10 °C ... +50 °C Storage temperature –25 °C ... +50 °C Vibration resistance 5 g, 10 Hz ... 150 Hz (IEC 61496-1, IEC 61496-3) Shock resistance 10 g, 16 ms (IEC 61496-1, IEC 61496-3) Other information Type of light Pulsed laser diode Wave length 905 nm 2017-05-30 12:10:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 3
A B C D E F H I J K L M N O P Q R S T S30A-6011DA | S3000 Professional SAFETY LASER SCANNERS Detectable remission 1.8 % ... > 1,000 %, reflectors Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) Dimensional drawing (Dimensions in mm (inch)) Area to be kept clear during installation of the scanner Axis of rotation of motor Connector range: approx. 270 (10.63) Reference points for mounting Beam diameter Sender = 15 (0.59) Beam diameter Receiver = 44 (1.73) 147 (5.79) 136.8 (5.39) M6 x 8 120 (4.72) 31.7 (1.25) 55 (2.17) (1.38) M8 x 9 M13.5 (0.91) 78.5 (3.09) 53.2 (2.09) 185 (7.28) 211 (8.31) 27.8 (1.09) 65.2 (2.57) 93 (3.66) 160 (6.30) 63 (2.48) 77.5 (3.05) 155 (6.10) 92.5 (3.64) 155 (6.10) 211 (8.31) 185 (7.28) 31.7 (1.25) 63 (2.48)
4 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-30 12:10:04
Subject to change without notice
S30A-6011DA | S3000 Professional SAFETY LASER SCANNERS Connection diagram Protective field switching with static and dynamic inputs S3000 Professional A1 A2 B1 B2 C 90°0° – + 1/f HTL 90°0° – + 1/f HTL DK1 0 V +24 V FE K2 H8 H2 k2 k1 x x y y z z E112710/01/2015-03-25 S3000 Professional in conjunction with relays/contactors Operating mode: without restart interlock with external device monitoring (EDM) Dynamic protective field switching using B1 and B2 as well as static protective field switching using the control inputs A and B Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. S3000 Professional in conjunction with relays/contactors Operating mode: with restart interlock and external device monitoring Static protective field switching by means of the control inputs A, B, C and D Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. 2017-05-30 12:10:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5
A B C D E F H I J K L M N O P Q R S T S30A-6011DA | S3000 Professional SAFETY LASER SCANNERS Protective field switching with four static inputs +24 V 0 V S3000 Professional A1 A2 B1 B2 C1 C2 D2 D1 K1 K2 H8 H3 H2 k2 k1 x x y y z z E112709/00/2014-03-06 S3000 Professional in conjunction with relays/contactors Operating mode: without restart interlock with external device monitoring (EDM) Dynamic protective field switching using B1 and B2 as well as static protective field switching using the control inputs A and B Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. S3000 Professional in conjunction with relays/contactors Operating mode: with restart interlock and external device monitoring Static protective field switching by means of the control inputs A, B, C and D Comments 1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state is disabled. For categories 4 and 3, this integration must be dual-channel (x/y paths). Single-channel insertion in the control (z path) is only possible with a single-channel control and by taking the risk analysis into account. Recommended accessories Other models and accessories www.sick.com/S3000_Professional Brief description Type Part no. Mounting brackets and plates 1 piece, Visor for heavy duty mounting kit (2080350), steel, painted (RAL 1021) Heavy duty sight 2083733
6 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2017-05-30 12:10:04
Subject to change without notice
S30A-6011DA | S3000 Professional SAFETY LASER SCANNERS Brief description Type Part no. 1 piece, Mounting bracket, heavy-duty version, with protection cover, for floor mount- ing, adjustable longitudinal and lateral axes via alignment plate, height adjustment possible. Tilt angle ± 5º. Additional mounting brackets are not required., steel, painted (RAL 1021) Heavy-duty mounting kit 2080350 1 piece, mounting bracket for direct mounting, from the rear, on wall or machine, not adjustable Mounting kit 1 2015623 1 piece, mounting bracket for rear mounting on wall or machine, adjustable longitudi- nal and lateral axes, only in conjunction with mounting kit 1 (2015623) Mounting kit 2 2015624 1 piece, mounting bracket for rear mounting on wall, floor, or machine, adjustable longitudinal and lateral axes, only in conjunction with mounting kit 1 (2015623) and 2 (2015624) Mounting kit 3 2015625 Plug connectors and cables Connecting cable 6025729 Head A: cable Head B: cable Cable: PVC, unshielded Connecting cable 6025730 Head A: cable Head B: cable Cable: PVC, shielded Fitting for EFI connections EFI connecting cable 6029448 Head A: male connector, M8, 4-pin, straight Head B: male connector, USB-A, straight Cable: PVC, unshielded, 2 m DSL-8U04G02M025KM1 6034574 Head A: male connector, M8, 4-pin, straight Head B: male connector, USB-A, straight Cable: PVC, unshielded, 10 m DSL-8U04G10M025KM1 6034575 Head A: system plug Cable: without cable Not for use of incremental encoders, integrated configuration storage SX0A-A0000B 2023797 Head A: system plug Cable: without cable For use of incremental encoders, integrated configuration storage SX0A-A0000D 2023310 Head A: system plug Cable: pre-assembled, For use of incremental encoders, integrated configuration stor- age, PVC, unshielded, 5 m SX0A-B1305D 2027176 Head A: system plug Cable: pre-assembled, For use of incremental encoders, integrated configuration stor- age, PVC, unshielded, 10 m SX0A-B1310D 2027177 Head A: system plug Cable: pre-assembled, Not for use of incremental encoders, integrated configuration storage, PVC, unshielded, 5 m SX0A-B1705B 2027174 Head A: system plug Cable: pre-assembled, Not for use of incremental encoders, integrated configuration storage, PVC, unshielded, 10 m SX0A-B1710B 2027175 Head A: system plug Cable: pre-assembled, Not for use of incremental encoders, integrated configuration storage, PVC, unshielded, 20 m SX0A-B1720B 2027816 2017-05-30 12:10:04 | Online data sheet Subject to change without notice OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 7
SICK AG | Waldkirch | Germany | www.sick.com SICK At A GlAnCe SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica- tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and require- ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma- chine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” WOrldWIde preSenCe: Contacts and other locations – www.sick.com