Features
■Rectangular, height 40 mm ■Variable orientation of active face in 9 directions ■Plastic, PBT-GF30-VO ■High-luminance corner LEDs ■Optimum view of operating voltage and switching state from any position ■Thread, 1/2-14 NPT ■DC 2-wire, nom. 8.2 VDC ■Output acc. to DIN EN 60947-5-6 (NAMUR) ■Terminal chamber ■ATEX category II 2 G, Ex Zone 1 ■ATEX category II 1 D, Ex Zone 20 ■SIL 2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 ■SIL 3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1 Wiring diagram Functional principle Inductive sensors detect metal objects contactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil.
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|3 BI15-CP40-Y1X/S10 | 11/07/2023 13-37 | technical changes reserved Technical data Mechanical data Design Rectangular, CP40 Dimensions 114 x 40 x 40 mm Housing material Plastic, PBT-GF30-V0, Black Active area material Plastic, PBT-GF30-V0, yellow Electrical connection Terminal chamber Clamping ability ≤ 2.5 mm² Environmental conditions Ambient temperature -25…+70 °C Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 Switching state 2 × LEDs, Yellow Mounting instructions Mounting instructions/Description Distance D 2 x B Distance W 3 x Sn Distance S 1 x B Distance G 6 x Sn Width active area B 40 mm Accessories JS025/037 69429 Adjusting bar for rectangular housings CK/CP40; material: VA 1.4301 BSS-CP40 6901318 Mounting clamp for rectangular housings 40 x 40 mm; material: Polypropylene
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|3 BI15-CP40-Y1X/S10 | 11/07/2023 13-37 | technical changes reserved Instructions for use Intended use This device fulfills Directive 2014/34/EC and is suited for use in areas exposed to explosion hazards according to EN 60079-0:2018 and EN 60079-11:2012.Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508.In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 2 G and II 1 D (Group II, Category 2 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) Ex II 2 G and Ex ia IIC T6 Gb and Ex II 1 D Ex ia IIIC T135 °C Da acc. to EN 60079-0, -11 Local admissible ambient temperature -25…+70 °C Installation/Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values.After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14).Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device.If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields.The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation avoid static charging Service/Maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.