  • Designed for very high insertion loss for Delta three phase, three wire applications
  • Available with common or differential mode coils O rdering Inform ation

100 ADT 6 S

Suffix S – Differential mode coils Omit if none Input / Output Style 6 – Threaded bolt ADT Series Current Rating 63, 100, 160 or 200A Specifications E lectrical Schem atics A B C A B C LINE LOAD 63ADT6 UL Recognized A vailable Part Num bers 63ADT6 63ADT6S 100ADT6 100ADT6S 160ADT6 160ADT6S 200ADT6 200ADT6S Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com High Performance High Current 3-phase Delta RFI Filters A D T Series ADT Series Maximum leakage current at 277 VAC 60 Hz, each Line to Ground: ADT6: 1.3 A 63ADT6S: 2.6 A 100, 160, 200ADT6S 4.6 A Hipot rating (one minute): Line to Ground: 2210 VDC Line to Line: 2158 VDC Rated Voltage (max): Phase to Phase: 480 VAC Phase to Ground: 277 VAC Operating Frequency: 50/60 Hz Rated Current: 63 to 200A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (T a) higher than +40°C the maximum operating current (Io) is calculated as follows: Io= Ir(85-Ta)/45

Part No. A B C D E F G H J K 63ADT6 63ADT6S 100ADT6 100ADT6S 160/200ADT6 160/200ADT6S 100, 160 & 200 ADT6 C ase Style CL CL CL CL 0.75 0.69 Typ. See Note 3/8-16 Thread (7x) Mounting Bracket 0.75 x 0.44 Slot (2x) H A F G B J C E K (2x)D (2x) 2.00 1.00 1.18 x 0.56 Slot (2x) 2.0 Max. (6x) 0.75 (2x) 0.75 G Line Load E lectrical Schem atics (continued) A B C A B C LINE LOAD ADT6S A B C A B C LINE LOAD High Performance High Current 3-phase Delta RFI Filters (continued) ADT Series 102 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com

Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 63ADT6 db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz 100ADT6 160ADT6 200ADT6 Measured in closed 50 Ohm system Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 63ADT6S 100ADT6S 160ADT6S 200ADT6S 2Three Phase Filters High Performance High Current 3-phase Delta RFI Filters (continued) ADT Series 103 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 For email, phone or live chat, please go to te.com/help corcom.com db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz db 100 0 0.01 0.1 1 10 100 300 Frequency in MHz