100000041 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Edition • 2023-07-21T15:41:53+02:00 CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP with WebVisu License BL67-PG-EN-V3-WV Type BL67-PG-EN-V3-WV ID 100000041 Supply voltage 24 VDC System power supply 24 VDC/5 VDC Field supply 24 VDC Admissible range 18…30 VDC Nominal current from module bus ð 100 mA Max. sensor supply Isens 4 A Short circuit fuse max. load current Io 10 A Max. field supply current 10 A Max. system supply current 1.2 A Voltage supply connection 5-pin male 7/8" connector Fieldbus transmission rate 10/100 Mbps, Full/Half Duplex, Auto Negotiation, Auto Crossing Fieldbus addressing Rotary switch, PGM, DHCP Fieldbus connection technology 2 x M12, 4-pin, D-coded PLC data Programming CODESYS V3 Released for CODESYS version V 3.5.8.10 Programming languages IEC 61131-3 (IL, LD, FBD, SFC, ST) Application tasks 5 Programming interface Ethernet, USB Processor ARM, 32 Bit Cycle time < 1 ms for 1000 IL commands (without I/O cycle) Real time clock yes Program memory 1024 kByte Data memory 512 kByte Input data 4 kByte Output data 4 kByte Non-volatile memory 16 kByte Web server 192.168.1.254 (Default) Service interface Ethernet, mini USB ■ CODESYS V3 PLC Runtime ■ CODESYS WebVisu license ■ CODESYS OPC UA server/client ■ IIoT gateway for Turck Cloud ■ PROFINET device ■ EtherNet/IP device ■ Modbus TCP master/slave ■ Protection class IP67 ■ LEDs for display of PLC status, supply voltage, group and bus faults ■ 2 × M12 Ethernet, 4-pin, D-coded ■ Switched or dual MAC mode ■ 10 Mbps/100 Mbps ■ 7/8″ male connector for power supply, 5- pin Functional principle The programmable BL67 gateways can be used as autonomous PLCs or as decentral PLCs in a network interconnection for fast pre- processing of signals. BL67 gateways are the head component of a BL67 station. The BL67 extension modules communicate via the internal module bus with the gateway and can be configured indepen- dently of the fieldbus protocol.

Edition • 2023-07-21T15:41:53+02:00 Modbus TCP Addressing Static IP, DHCP Supported function codes FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, FC23 Input Data Size max. 1024 register Input register start address 0 (0x0000 hex) Output Data Size max. 1024 register Output register start address 0 (0x0000 hex) Ethernet/IP Addressing acc. to EtherNet/IP specification Device Level Ring (DLR) not supported Input Data Size 248 INT Output Data Size 248 INT PROFINET Addressing DCP Conformance class B (RT) MinCycleTime 1 ms Diagnostics acc. to PROFINET alarm handling Topology detection supported Automatic addressing supported Media Redundancy Protocol (MRP) not supported Input Data Size max. 512 BYTE Output Data Size max. 512 BYTE Dimensions (W x L x H) 74 x 145 x 77.5 mm Ambient temperature -25…+70 °C Temperature derating > 55 °C Circulating air (Ventilation) Derating: Max. power consumption = 5 A > 55 °C Steady ambient air Derating: Max. power consumption = 5 A Storage temperature -40…+85 °C Relative humidity 15…95 % (internal), level RH-2, no condensation (when stored at 45 °C) Vibration test Acc. to EN 61131 - up to 5 g (at 10 to 150 Hz) for mounting on DIN rail no drilling according to EN 60715, with end bracket - up to 20 g (at 10 up to 150 Hz) for mounting on base plate or machinery Therefore every second module has to be mounted with two screws each. Shock test Acc. to IEC 60068-2-27 Drop and topple acc. to IEC 68-2-31 and free fall to IEC 68-2-32 Electromagnetic compatibility Acc. to EN 61131-2 Protection class IP67 MTTF 116 years acc. to SN 29500 (Ed. 99) 20 °C DIN rail mounting yes, Attention: Offset Direct mounting Two mounting holes, Ø 6 mm Included in delivery 1 x end plate BL67

Edition • 2023-07-21T15:41:53+02:00 Ethernet The M12 D-coded Ethernet ports are used as interface for con- figuration, programming, and fieldbus communication. The gate- way can be operated as a master or slave on a PROFINET, Ether- Net/IP™ or Modbus TCP network. Ethernet Cordset (Example): M12-M12: RSSD RSSD 441-2M Ident no. U-02482 M12-RJ45: RSSD RJ45S 441-2M Ident. no. U3-00525 Pin Assignment Power Supply The BL67 system is supplied via two 24VDC voltage groups. System supply Vi VI supplies power to the sensor supply (Vsens) and the internal sys- tem supply, which includes Ethernet communication and the back- plane bus that communicates with any connected I/O modules. Field supply Vo VO supplies power to the outputs of any connected I/O modules. Power Cordset (Example): 7/8"-7/8": RSM RKM 50-2M Ident. no. U2282-0 7/8" single-ended: RKM 50-2M Ident. no. U2056 Pin Assignment Power Supply USB Host Port Storage media can be connected to the USB host port, please ob- serve the instructions in the user manual. Pin Assignment USB Device Port The USB device port can be used as a programming and service interface. Pin Assignment

Edition • 2023-07-21T15:41:53+02:00 Function accessories Type code Ident-No. Dimension drawing BL67-LABEL-DIN- A4-50STCK.

6827196 Labels for electronic modules and gateways, DIN A5 sheets,

perforated, laser printing, 50 pcs.