www.lumberg-automationusa.com 800-235-3361 or 1-800-BELDEN1 9 Be Certain with Belden PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs Type 0980 ESL 710 Product Description LioN-M EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8" power supply. Diagnostic indiction LED Indication Condition 1...8 A Yellow Channel status 1 1...8 DIA A Red Periphery fault 1... 8 B Yellow Channel status 2 1... 8 DIA B Red Periphery fault US Green Off Sensor power supply applied Sensor power supply missing UL Green Off Actuator power supply applied Actuator power supply missing P1 Lnk/Act Green Yellow flashing Connected to an Ethernet device I/O device exchanging data P2 Lnk/Act Green Green flashing Connected to an Ethernet device I/O device exchanging data MS (Module status) Green Green flashing Red/Green flashing Red flashing Off Device is ready for operating Wrong configuration Self test is running Firmware update Device is off NS (Network status) Green Green flashing Red Red flashing Off Connection to master exists IP address exists, but no connection to the master IP address is used by a different device Connection has timed out Device is off Part number Order number

0980 ESL 710 0980 ESL 710

Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A M12 Output Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A Pin assignment LAN connection M12, D-coded Power supply 7/8" Input/Output M12 1 = TD+ 2 = RD+ 3 = TD- 4 = RD Housing = shielding 1 = +24V Actuators 2 = +24V System/Sensors 3 = GND (0V) System/Sensors 4 = GND (0V) Actuators Housing = FE 1 = +24V 2 = IN/OUT B 3 = GND (0V) 4 = IN/OUT A 5 = earth Housing = FE www.lumberg-automationusa.com 800-235-3361 or 1-800-BELDEN1 9 Be Certain with Belden PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs Type 0980 ESL 710 Product Description LioN-M EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8" power supply. Diagnostic indiction LED Indication Condition 1...8 A Yellow Channel status 1 1...8 DIA A Red Periphery fault 1... 8 B Yellow Channel status 2 1... 8 DIA B Red Periphery fault US Green Off Sensor power supply applied Sensor power supply missing UL Green Off Actuator power supply applied Actuator power supply missing P1 Lnk/Act Green Yellow flashing Connected to an Ethernet device I/O device exchanging data P2 Lnk/Act Green Green flashing Connected to an Ethernet device I/O device exchanging data MS (Module status) Green Green flashing Red/Green flashing Red flashing Off Device is ready for operating Wrong configuration Self test is running Firmware update Device is off NS (Network status) Green Green flashing Red Red flashing Off Connection to master exists IP address exists, but no connection to the master IP address is used by a different device Connection has timed out Device is off Part number Order number Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A M12 Output Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A Pin assignment LAN connection M12, D-coded Power supply 7/8" Input/Output M12 1 = TD+ 2 = RD+ 3 = TD- 4 = RD Housing = shielding 1 = +24V Actuators 2 = +24V System/Sensors 3 = GND (0V) System/Sensors 4 = GND (0V) Actuators Housing = FE 1 = +24V 2 = IN/OUT B 3 = GND (0V) 4 = IN/OUT A 5 = earth Housing = FE 1-717-217-2299 www.lumberg-automationusa.com10 LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs Type 0980 ESL 710 Product Description LioN-M EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply. Diagnostic indiction LED Indication Condition 1...8 A Yellow Channel status 1 1...8 DIA A Red Periphery fault 1... 8 B Yellow Channel status 2 1... 8 DIA B Red Periphery fault US Green Off Sensor power supply applied Sensor power supply missing UL Green Off Actuator power supply applied Actuator power supply missing P1 Lnk/Act Green Yellow flashing Connected to an Ethernet device I/O device exchanging data P2 Lnk/Act Green Green flashing Connected to an Ethernet device I/O device exchanging data MS (Module status) Green Green flashing Red/Green flashing Red flashing Off Device is ready for operating Wrong configuration Self test is running Firnware update Device is off NS (Network status) Green Green flashing Red Red flashing Off Connection to master exists IP address exists, but no connection to the master IP address is used by a different device Connection has timed out Device is off Part number Order number Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A M12 Output Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A Pin assignment LAN connection M12, D-coded Power supply 7/8” Input/Output M12 1 = TD+ 2 = RD+ 3 = TD- 4 = RD Housing = shielding 1 = +24 V Actuators 2 = +24 V Logic / Sensors 3 = GND (0 V) Logic / Sensors 4 = GND (0 V) Actuators Housing = FE 1 = +24 V 2 = IN/OUT B 3 = GND (0 V) 4 = IN/OUT A 5 = earth Housing = FE LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs Type 0980 ESL 710 Product Description LioN-M EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply. Diagnostic indiction LED Indication Condition 1...8 A Yellow Channel status 1 1...8 DIA A Red Periphery fault 1... 8 B Yellow Channel status 2 1... 8 DIA B Red Periphery fault US Green Off Sensor power supply applied Sensor power supply missing UL Green Off Actuator power supply applied Actuator power supply missing P1 Lnk/Act Green Yellow flashing Connected to an Ethernet device I/O device exchanging data P2 Lnk/Act Green Green flashing Connected to an Ethernet device I/O device exchanging data MS (Module status) Green Green flashing Red/Green flashing Red flashing Off Device is ready for operating Wrong configuration Self test is running Firnware update Device is off NS (Network status) Green Green flashing Red Red flashing Off Connection to master exists IP address exists, but no connection to the master IP address is used by a different device Connection has timed out Device is off Part number Order number Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A M12 Output Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A Pin assignment LAN connection M12, D-coded Power supply 7/8” Input/Output M12 1 = TD+ 2 = RD+ 3 = TD- 4 = RD Housing = shielding 1 = +24 V Actuators 2 = +24 V Logic / Sensors 3 = GND (0 V) Logic / Sensors 4 = GND (0 V) Actuators Housing = FE 1 = +24 V 2 = IN/OUT B 3 = GND (0 V) 4 = IN/OUT A 5 = earth Housing = FE 1.800.Belden1 | www.lumberg-automationusa.com

800-235-3361 or 1-800-BELDEN1 www.lumberg-automationusa.com10 PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG Environmental Degree of protection IP 67 Operating temperature range -10° C (+14°F) to +60° C (+140°F) Mechanical Weight 380 g Housing material PBT Bus system EtherNet/IP Vendor ID 21 Device ID 710 EDS-File EDS-v3.9 - LumbergAutomation-0980ESL710-20110420.eds (or later) Transmission rate 10/100 Mbs Address range 0-255 Rotary address switches 0-255 Default address 1 System/Sensors power supply System power supply Nominal voltage 24V DC Voltage range 11–30V DC Power consumption typ. 90 mA Reverse polarity protection yes Input power supply US Voltage range 19–30V DC Sensor current 200 mA per port (at Tamb 30° C) Short-circuit proof yes Indication LED green Inputs Type 3 acc. to IEC 61131-3 Rated input voltage 24V DC Channel type N.O. p-switching Number of digital channels max. 16 Channel status indicator LED yellow per channel Diagnostic indication LED red per socket Output power supply UL Rated voltage 24V DC Voltage range 19–30V DC Reverse polarity protection yes/antiparallel diode Indication LED green Outputs Rated output current 1.6 A per channel Short-circuit proof yes Max. output current 9 A (12 A*) per module *Test proven and approved under the following conditions:

  • looped through System/Sensor power supply max. 2.5 A
  • Power supply cable STL 204 (5x1.00 mm2)
  • Operating temperature range max. 40° C Overload-proof yes Number of digital channels max. 16 Channel type N.O. p-switching Channel status indicator LED yellow per channel Diagnostic indication LED red per socket Included in delivery/accessories Dust covers M12 4 pieces Attachable labels 10 pieces LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs The application of these products in harsh environments should always be checked before use. Specifications subject to alteration. 800-235-3361 or 1-800-BELDEN1 www.lumberg-automationusa.com10 PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG PROFINET-ETHERNET_IP-ETHERNET-CON-SOLUTIONS_CA_V3_ICOS_LUM_0415_A_AG Environmental Degree of protection IP 67 Operating temperature range -10° C (+14°F) to +60° C (+140°F) Mechanical Weight 380 g Housing material PBT Bus system EtherNet/IP Vendor ID 21 Device ID 710 EDS-File EDS-v3.9 - LumbergAutomation-0980ESL710-20110420.eds (or later) Transmission rate 10/100 Mbs Address range 0-255 Rotary address switches 0-255 Default address 1 System/Sensors power supply System power supply Nominal voltage 24V DC Voltage range 11–30V DC Power consumption typ. 90 mA Reverse polarity protection yes Input power supply US Voltage range 19–30V DC Sensor current 200 mA per port (at Tamb 30° C) Short-circuit proof yes Indication LED green Inputs Type 3 acc. to IEC 61131-3 Rated input voltage 24V DC Channel type N.O. p-switching Number of digital channels max. 16 Channel status indicator LED yellow per channel Diagnostic indication LED red per socket Output power supply UL Rated voltage 24V DC Voltage range 19–30V DC Reverse polarity protection yes/antiparallel diode Indication LED green Outputs Rated output current 1.6 A per channel Short-circuit proof yes Max. output current 9 A (12 A*) per module *Test proven and approved under the following conditions:
  • looped through System/Sensor power supply max. 2.5 A
  • Power supply cable STL 204 (5x1.00 mm2)
  • Operating temperature range max. 40° C Overload-proof yes Number of digital channels max. 16 Channel type N.O. p-switching Channel status indicator LED yellow per channel Diagnostic indication LED red per socket Included in delivery/accessories Dust covers M12 4 pieces Attachable labels 10 pieces LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs The application of these products in harsh environments should always be checked before use. Specifications subject to alteration. 1-717-217-2299 www.lumberg-automationusa.com10 LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs Type 0980 ESL 710 Product Description LioN-M EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply. Diagnostic indiction LED Indication Condition 1...8 A Yellow Channel status 1 1...8 DIA A Red Periphery fault 1... 8 B Yellow Channel status 2 1... 8 DIA B Red Periphery fault US Green Off Sensor power supply applied Sensor power supply missing UL Green Off Actuator power supply applied Actuator power supply missing P1 Lnk/Act Green Yellow flashing Connected to an Ethernet device I/O device exchanging data P2 Lnk/Act Green Green flashing Connected to an Ethernet device I/O device exchanging data MS (Module status) Green Green flashing Red/Green flashing Red flashing Off Device is ready for operating Wrong configuration Self test is running Firnware update Device is off NS (Network status) Green Green flashing Red Red flashing Off Connection to master exists IP address exists, but no connection to the master IP address is used by a different device Connection has timed out Device is off Part number Order number

Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A M12 Output Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A Pin assignment LAN connection M12, D-coded Power supply 7/8” Input/Output M12 1 = TD+ 2 = RD+ 3 = TD- 4 = RD Housing = shielding 1 = +24 V Actuators 2 = +24 V Logic / Sensors 3 = GND (0 V) Logic / Sensors 4 = GND (0 V) Actuators Housing = FE 1 = +24 V 2 = IN/OUT B 3 = GND (0 V) 4 = IN/OUT A 5 = earth Housing = FE LioN-M EtherNet/IP I/O Modules with 16 Digital Inputs and 16 Digital Outputs Type 0980 ESL 710 Product Description LioN-M EtherNet/IP Device with 16 digital I/O channels, channels can be used universally as inputs or outputs, M12 socket, rotary address switches for addressing, M12 LAN-Ports, D-coded, 7/8“ power supply. Diagnostic indiction LED Indication Condition 1...8 A Yellow Channel status 1 1...8 DIA A Red Periphery fault 1... 8 B Yellow Channel status 2 1... 8 DIA B Red Periphery fault US Green Off Sensor power supply applied Sensor power supply missing UL Green Off Actuator power supply applied Actuator power supply missing P1 Lnk/Act Green Yellow flashing Connected to an Ethernet device I/O device exchanging data P2 Lnk/Act Green Green flashing Connected to an Ethernet device I/O device exchanging data MS (Module status) Green Green flashing Red/Green flashing Red flashing Off Device is ready for operating Wrong configuration Self test is running Firnware update Device is off NS (Network status) Green Green flashing Red Red flashing Off Connection to master exists IP address exists, but no connection to the master IP address is used by a different device Connection has timed out Device is off Part number Order number Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A M12 Output Byte 0 4B 4A 3B 3A 2B 2A 1B 1A Byte 1 8B 8A 7B 7A 6B 6A 5B 5A Pin assignment LAN connection M12, D-coded Power supply 7/8” Input/Output M12 1 = TD+ 2 = RD+ 3 = TD- 4 = RD Housing = shielding 1 = +24 V Actuators 2 = +24 V Logic / Sensors 3 = GND (0 V) Logic / Sensors 4 = GND (0 V) Actuators Housing = FE 1 = +24 V 2 = IN/OUT B 3 = GND (0 V) 4 = IN/OUT A 5 = earth Housing = FE 1.800.Belden1 | www.lumberg-automationusa.com