07LC-10T BEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output

  • Isolated • Low Cost
  • High Efficiency • OCP/SCP
  • High Power Density
  • Excellent Thermal Performance
  • Output Over-voltage Protection

Description

The 07LC-10T Series converters are isolated DC/DC c onverters that operate from a nominal 48V source. These converters provide up to 12W of output power. These units are des igned to be highly efficient and cost- effective. Features include remote on/off, short circuit prot ection, over-current protection, and output over- voltage protection. These converters are provided in a compact, industry standard package. Part Selection Output Voltage Input Voltage Max. Output Current Max. Output Power Typical Efficiency Model Number 5V 36 – 72V 2A 10W 82% 07LC-10T050 12V 36 – 72V 1A 12W 83% 07LC-10T120 24V 36 – 72V 0.5A 12W 85% 07LC-10T240 Note: Add “G” suffix at the end of the model number to indicate Tray Packaging. Absolute Maximum Ratings Parameter Min Typ Max Notes Input Voltage (continuous) -0.3V - 72V Input Voltage (peak/surge) - - 100V 100ms non-repetitive Remote On/Off (Active Low) -0.3V - 18V Remote On/Off (Active High) -0.3V - 7V Output Power - - 12W Ambient Temperature 0°C - 70°C Storage Temperature -40°C - 125°C Input Specifications Parameter Min Typ Max Notes Input Voltage 36V - 72V Input Current (no load) - 25mA 40mA Input Current (full load) - - 0.45 A Remote Off Input Current (Active Low) - 5mA 10mA Remote Off Input Current (Active High) - 10mA Input Reflected Ripple Current (pk-pk) - 15mA 30mA Input Reflected Ripple Current (RMS) - 5mA 10mA Tested with simulated source impedance of 10uH, 5Hz to 20MHz; use a 47uF/100V electrolytic capacitor with ESR = 1 ohm max. at 200KHz at 25°C I2t Inrush Current Transient - 0.039A 2s 0.062A 2s Turn-on Voltage Threshold - 30V - Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated. 07LC-10T Series

Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Output Specifications Parameter Min Typ Max Notes Output Voltage Set Point VO=5V VO=12V VO=24V 4.850V 11.64V 23.28V 5.00V 12.00V 24.00V 5.150V 12.36V 24.72V Vin=48V for all outputs Line Regulation VO=5V VO=12V VO=24V 10mV 20 mV 35 mV 15 mV 36 mV 48 mV Load Regulation VO=5V VO=12V VO=24V 15mV 36 mV 48 mV 25 mV 60 mV 80 mV Regulation Over Temperature (0°C to 70°C) - 75mV 150mV Output Current VO=5V VO=12V VO=24V 0.2A 0.1A 0.05A 0.5A Current Limit Threshold (VO= 90% VO, nom) VO=5V VO=12V VO=24V 1.5A 0.75A Short Circuit Surge Transient - TBD - A 2s Ripple and Noise (RMS) VO=5V VO=12V VO=24V 18mV 21mV 45mV 30mV 40mV 70mV 0 - 20MHz Bandwidth with 1uF ceramic load capacitance Ripple and Noise (pk-pk) VO=5V VO=12V VO=24V 60mV 80mV 120mV 100mV 120mV 180mV 0 - 20MHz Bandwidth with 1uF ceramic load capacitance Turn on Time - 2mS - Overshoot at Turn on - 0% 3% Output Capacitance VO=5V VO=12V VO=24V 0uF 0uF 0uF 800uF 100uF 20uF Transient Response Overshoot - 100mV 150mV 50% ~ 100% Max Load Settling Time - 100uS 150uS Overshoot - 100mV 150mV 100% ~ 50% Max Load Settling Time VO=5V - 100uS 150uS Overshoot - 150mV 250mV 50% ~ 100% Max Load Settling Time - 150uS 200uS Overshoot - 150mV 250mV 100% ~ 50% Max Load Settling Time VO=12V - 150uS 200uS Overshoot - 350mV 500mV 50% ~ 100% Max Load Settling Time - 200uS 250uS Overshoot - 350mV 500mV 100% ~ 50% Max Load Settling Time VO=24V - 200uS 250uS di/dt = 0.1A/uS; Vin = 48V; Ta = 25°C and 1uF ceramic capacitance Note: All specifications are typical at nominal input, full load at 25°C unless otherwise stated.

Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output General Specifications Parameter Min Typ Max Notes Efficiency VO=5V VO=12V VO=24V 78% 79% 81% 82% 83% 85% Vin=48V, IO= IO, max Switching Frequency 200KHz 250KHz 300KHz Output Trim Range 95%V O - 105%V O For all outputs Protection Features Overvoltage Protection Setpoint VO=5V VO=12V VO=24V 6.8V 15V 30V MTBF 2,000,000 hours Calculated Per Bell Core TR-332 (IO = Nomal; Ta = 25°C) Isolation - 1500 V - Dimensions Inches (L × W × H) Millimeters (L × W × H) 1.91 x 0.98 x 0.477 48.51 x 24.89 x 12.12 Weight - 10.3g - Note: All specifications are typical at 25°C unless otherwise stated. Control Specifications Parameter Min Typ Max Notes Remote On/Off Signal Low (Unit On) -0.3V - 0.8V Signal High (Unit Off) Active Low 2.4V - 18V Signal Low (Unit Off) -0.3V - 0.8V Signal High (Unit On) Active High 2.4V - 7V The remote on/off pin open, Unit On. Output Trim Equations Equations for calculating the trim resistor (in k Ω) given the desired adjusted voltage (Vadj) and the nominal output voltage of the converter (Vnom) are shown below. The Trim Down resistor should be connected between the Trim pin and Vout. The Trim Up resistor should be connected between the Trim pin and Ground. Only one of the resistors should be used for any given application. BVV AR adjnom TrimDown −−= DVV CR nomadj TrimUp −−= Vnom A B C D 24 489.490 28.310 26.660 6.810 12 113.550 16.990 13.020 6.490 5 56.410 51.200 18.228 36.500 Module Vout Trim GND Rtrimup Module Vout Trim GND Rtrimdown

Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Efficiency Data 07LC-10T050 07LC-10T120 07LC-10T240 50.00% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% OUTPUT CURRENT (A) EFFICIENCY 36V 48V 72V 50.00% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% OUTPUT CURRENT (A) EFFICIENCY 36V 48V 72V 50.00% 55.00% 60.00% 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% OUTPUT CURRENT EFFICIENCY 36V 48V 72V

Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Thermal Derating Curves Vo=5V, Io=2A Vo=12V, Io=1A Vo=24V, Io=0.5A

©2004 Bel Fuse Inc. Specifications subject to change without notice. 120304 CORPORATE FAR EAST EUROPE Bel Fuse Inc. Bel Fuse Ltd. Bel Fuse Europe Ltd.

206 Van Vorst Street 8F/ 8 Luk Hop Street Preston Technology Management Centre

Jersey City, NJ 07302 San Po Kong Marsh Lane, Suite G7, Preston Tel 201-432-0463 Kowloon, Hong Kong Lancashire, PR1 8UD, U.K. Fax 201-432-9542 Tel 852-2328-5515 Tel 44-1772-556601 www.belfuse.com Fax 852-2352-3706 Fax 44-1772-888366 www.belfuse.com www.belfuse.com ISOLATED DC/DC CONVERTERS 48V Input / 5V/2A or 12V/1A or 24V/0.5A Output Pin Connections Pin Function

1 V in+

2 V in-

3 Remote On/Off

4 V o+

5 Trim

6 V o-

Note: Remote On/Off pin open, unit on.