www.elma.com DATA SHEET HOLD-UP BOARD

DESCRIPTION

In normal operation, the input voltage will feed thru to the PSU and the hold-up capacitors will be charged. In case of a voltage drop of the input voltage, the input voltage will be disconnected and the PSU will be supplied by the hold-up capacitors. MECHANICAL DETAILS The Hold Up board is available as a fixed mounted and a plugged version. For conducted cooled chassis, additional wedge locks can be mounted. Mating connectors Fixed mounted version: FCT FL21WA4S7-K121 Pluggable version (PCB): FCT FM21WA4P22-1277 Part numbers Hold-Up Module PCB only w/o cover: 055-149 Hold-Up Module with additional cover: 064-474

www.elma.com DATA SHEET HOLD-UP BOARD INPUT CHARACTERISTICS Input voltage 16-36 VDC Over voltage protection according MIL-STD 704A-F Electromagnetic compatibility according MIL-STD 461F Reverse voltage protection max. -40 VDC Inrush current max. 3,5 A Capacitors load current max. 1,5 A GENERAL SPECIFICATIONS Maximum provided power 330 W Hold up time according MIL-STD 704 / DO160, 50ms for up to 330 W Under voltage trigger level 17 ,3 VDC ENVIRONMENTAL Operating temperature -40 +85C° Storage temperature -40 +85°C Humidity 95% non condensing Shock MIL-STD-810F Vibration MIL-STD-810F