08_canalineEN.indd 208_canalineEN.indd 2 23-11-2007 8:10:5223-11-2007 8:10:52

For cabling in electrical switchboards and cabinets, ABB Sace has the wiring ducts you need for every application: with slots or with knock-outs, fl exible and in lead-free and halogen-free thermoplastics. The fi rst on the market to be awarded the EN 50085-2-3 conformity, ABB wiring ducts are now available in new versions that are even more practical, safer and faster to install. Discover the new features. Lead-free thermoplastic ducts with vertical slots 8-12 / 4-6 mm Twenty-eight combinations of base and height, up to 150 mm x 100 mm when you need plenty of space for your cables. The new cover and strong sides contain and protect cables, and the system features rapid installation and rib removal that won’t hurt your hands. Whatever you need, ABB has got what you’re looking for. Thermoplastic ducts with knock-outs The circular knock-outs on the sides protect the cables from dirt and dust (IP40) and facilitate branch connections using rigid and corrugated conduits and cables. These ducts are ideal for use in lift rooms and similar locations. Flexible thermoplastic ducts For cabling routes that are subject to fl exion and torsion, these ducts bend without breaking or damaging the cables inside. Affi x them with screws and rivets or with the special high-bond adhesive tape (suitable for use even on steel). Add and remove cables simply by splaying open the ribs. Better robustness Easy closing of covers 08_canalineEN.indd 308_canalineEN.indd 3 23-11-2007 8:10:5523-11-2007 8:10:55

Halogen-free thermoplastic ducts with vertical slots 8-12 / 4-6 mm Just as strong and easy to install, these ducts conform to VDE 0472, Part 815 which certifi es their safety in the event of fi re, limiting toxicity and opacity of smoke. Conforms to RoHS directive Safety: protects cables and operator Easy removal of ribs 08_canalineEN.indd 408_canalineEN.indd 4 23-11-2007 8:11:2123-11-2007 8:11:21

W x H (mm) No. metres in pack 8-12 mm slot 4-6 mm slot 05 019 05 119 15 x 17 46 05 033 05 133 25 x 30 58 05 035 05 135 40 x 30 38 05 037 05 137 60 x 30 52 05 043 05 143 25 x 40 48 05 045 05 145 40 x 40 30 05 047 05 147 60 x 40 40 05 049 05 149 80 x 40 32 05 051 05 151 100 x 40 24 05 053 05 153 120 x 40 20 05 063 05 163 25 x 60 34 05 065 05 165 40 x 60 22 05 067 05 167 60 x 60 32 05 069 05 169 80 x 60 24 05 071 05 171 100 x 60 20 05 073 05 173 120 x 60 14 05 083 05 183 25 x 80 28 05 085 05 185 40 x 80 36 05 087 05 187 60 x 80 24 05 089 05 189 80 x 80 16 05 091 05 191 100 x 80 16 05 093 05 193 120 x 80 12 05 094 05 194 25x100 20 05 095 05 195 40x100 28 05 096 05 196 60x100 20 05 097 05 197 80x100 14 05 098 05 198 100x100 8 05 099 05 199 150x100 8 Article Dimensions W x H (mm) No. pieces 05 400 12.5 x 12.5 112 05 402 16 x 16 84 05 405 20 x 20 112 05 410 25 x 25 70 05 415 30 x 30 50 05 420 40 x 40 50 05 425 50 x 50 32 Article Dimensions W x H (mm) No. metres in pack 05 330 50 x 50 36 05 331 100 x 60 18 With 8-12 / 4-6 mm slots  shock-resistant and self-extinguishing thermoplastic in conformity with UL 94 V0 standard, resistant to abnormal heat and fi re up to 960 °C (glow-wire test) in conformity with IEC 60695-2-1 standard  minimum storage/transport temperature -5 °C  minimum installation/use temperature -15 °C  maximum use temperature +60 °C  standard length 2 metres  colour RAL 7030 grey  conforms to EN 50085-2-3 standard  conforms to RoHS directive  lead-free  certifi cations: IMQ - UL - CSA - RINA Flexible  shock-resistant and self-extinguishing thermoplastic in conformity with UL 94 V0 standard, resistant to permanent temperature of 80 °C and peaks of up to 110 °C in conformity with IEC 216 standard  standard length 500 millimetres  colour RAL 7040 grey  conforms to RoHS directive With knock-outs  shock-resistant and self-extinguishing thermoplastic in conformity with UL 94 V0 standard, resistant to abnormal heat and fi re up to 960 °C (glow-wire test) in conformity with IEC 60695-2-1 standard  dimensional stability from -20 to +60 °C  standard length 2 metres  colour RAL 7030 grey  conforms to RoHS directive Article Description (mm) No. pieces box/pack Rapid fi xing for DIN rail 05 250 Duct width 25 20/600 05 252 Duct width 40 20/600 05 254 Duct width 60 20/600 05 256 Duct width 80 20/240 05 258 Duct width 100 20/240 05 260 Duct width 120 20/240 05 262 Duct width 150 20/240 Rapid fi xing for mounting plate 05 270 Duct width 25 20/600 05 272 Duct width 40 20/600 05 274 Duct width 60 20/600 05 276 Duct width 80 20/240 05 278 Duct width 100 20/240 05 280 Duct width 120 20/240 05 282 Duct width 150 20/240 Wiring ducts with vertical slots Flexible wiring ducts Wiring ducts with knock-outs Fix-O-Rapid Lead free RoHS compliance Lead-free thermoplastic ducts 08_canalineEN.indd 508_canalineEN.indd 5 23-11-2007 8:11:2923-11-2007 8:11:29

We’ve changed the profi le of the cover: now all you need to do is position it over the duct, and a light pressure snaps it into place over all the ribs together. The details that make the difference Not one line is out of place: the pre-scored lines at the base of each rib and inside the ducts sides enable you to make clean, precise openings for passing cables. You want the best. We’ll give it to you. Stronger and tougher The duct is now even stronger to contain and support cables in whatever position it’s installed. 08_canalineEN.indd 608_canalineEN.indd 6 23-11-2007 8:11:3523-11-2007 8:11:35

Attach the profi le and remove the rib, repeat the operation and in just a few seconds you have your cabling done. And it’s even faster and more precise with the special tools and accessories: the shears, the Fix-O- Rapid accessory for fi xing to DIN rails and mounting plates, and the rivet fastener. Total safety We know how you work. You can’t afford to make mistakes or lose time, and that’s why we develop materials and shapes that protect both you and your installations. You can handle our ducts practically and safely: the ribs bend up to around 90° without breaking and, like all other parts, they are free from burrs or sharp edges that could lead to abrasions on hands and cables. 08_canalineEN.indd 708_canalineEN.indd 7 23-11-2007 8:11:5223-11-2007 8:11:52

  • halogen free thermoplastic in conformity with VDE 0472 standard Part 815: Br + Cl < 0.2 %, F < 0.1 %
  • toxic smoke index: 25.78 in conformity with NF X70-100 and NF F16-101 standards
  • opacity of smoke*: Dm 352.2 (2 mm) V0F4 475.8 (2 mm) in conformity with NF X10- 702 standard (NF F16-101 reference)
  • based on the values obtained in the opacity and toxicity tests of smoke, the material belongs to class F2 (in conformity with NF F16-101 standard)
  • insulating, shock-resistant and self-extinguishing thermoplastic in conformity with UL 94 V0 standard, resistant to abnormal heat and fi re up to 850 °C (glow-wire test) in conformity with IEC 60695-2-1 standard
  • dimensional stability from -40 to +100 °C
  • standard length 2 m
  • colour RAL 7035 grey
  • conforms to EN 50085-2-3 standard
  • conforms to RoHS directive * in the event of fi re, it is extremely important that the degree of opacity of smoke during the fi rst 4 minutes is as reduced as possible in order to allow evacuation of persons from areas at risk Article Dimensions W x H (mm) No. metres in pack 8-12 mm slot 4-6 mm slot 1SL9019A00 1SL9119A00 15x17 46 1SL9033A00 1SL9133A00 25x30 58 1SL9035A00 1SL9135A00 40x30 38 1SL9037A00 1SL9137A00 60x30 52 1SL9043A00 1SL9143A00 25x40 48 1SL9045A00 1SL9145A00 40x40 30 1SL9047A00 1SL9147A00 60x40 40 1SL9049A00 1SL9149A00 80x40 32 1SL9051A00 1SL9151A00 100x40 24 1SL9053A00 1SL9153A00 120x40 20 1SL9063A00 1SL9163A00 25x60 34 1SL9065A00 1SL9165A00 40x60 22 1SL9067A00 1SL9167A00 60x60 32 1SL9069A00 1SL9169A00 80x60 24 1SL9071A00 1SL9171A00 100x60 20 1SL9073A00 1SL9173A00 120x60 14 1SL9083A00 1SL9183A00 25x80 28 1SL9085A00 1SL9185A00 40x80 36 1SL9087A00 1SL9187A00 60x80 24 1SL9089A00 1SL9189A00 80x80 16 1SL9091A00 1SL9191A00 100x80 16 1SL9093A00 1SL9193A00 120x80 12 Halogen-free thermoplastic ducts 08_canalineEN.indd 808_canalineEN.indd 8 23-11-2007 8:12:0123-11-2007 8:12:01

1SLC811004B0201 01/ ‘08 Printed in Italy 5.000 - CAL ABB SACE A division of ABB S.p.A. Enclosures and Cable Systems Viale Vicenza, 61

36063 Marostica (VI) - Italy

Tel.: +39 0424.478200 - Telefax: +39 0424.478305 http://bol.it.abb.com Due to possible developments of standards as well as of materials, the characteristics and dimensions specifi ed in the present catalogue may only be considered binding after confi rmation by ABB SACE. 08_canalineEN.indd 108_canalineEN.indd 1 23-11-2007 8:10:4623-11-2007 8:10:46