DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 13

Technical content

THIS COPYRIGHTED DOCUMENT IS THE PROPERTY OF GLENAIR, INC. AND IS FURNISHED ON THE CONDITION THAT IT IS NOT TO BE DISCLOSED, REPRODUCED IN WHOLE OR IN PART, OR USED TO SOLICIT QUOTATIONS FROM COMPETITIVE SOURCES, OR USED FOR MANUFACTURE BY ANYONE OTHER THAN GLENAIR, INC. WITHOUT WRITTEN PERMISSION FROM GLENAIR, INC. THE INFORMATION HEREIN HAS BEEN DEVELOPED AT GLENAIR'S EXPENSE AND MAY BE USED FOR ENGINEERING EVALUATION AND INCORPORATION INTO TECHNICAL SPECIFICATIONS AND OTHER DOCUMENTS WHICH SPECIFY PROCUREMENT OF PRODUCTS FROM GLENAIR, INC. 050-501 Copper to Fiber Aggregation Media Converter Flange Mount

12 Channel RS422/RS485, 28VDC,

Mighty Mouse (Signal & Power), GHD (Fiber Optic) REV DESCRIPTION DATE APPROVED 2 1/19/2015 BD

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 2 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Aggregation Media Converter – 12x RS422/RS485 The Glenair 050-501 is a Media Converter that aggregates (combines) 12 RS422/RS485 channels and then converts these to a serial stream to transport over fiber. It is designed for harsh environments and incorporates electronics in an environmentally sealed enclosure that incorporates two environmental connectors. One connector, Mighty Mouse, is utilized for power and electrical signal and the second connector, Glenair High Density, is used for the Fiber Optic signals and can be configured to support either single mode or multi-mode fiber applications. KEY FEATURES/BENEFITS  Hermetic 850nm VCSEL Lasers  Hermetic GaAs PIN/TIA  Wide Input Voltage Range: 5-36V  12 – Non-Isolated RS422/RS485 Transceivers  IP67 in mated condition  Mighty Mouse Electrical Signal & Power  Glenair High Density Fiber Optic Connector  Panel Mount or Flange Mount OPTIONAL FEATURES  Built In Test Console Port accessible via USB2.0 or UART

APPLICATIONS

  • Harsh Environment RS422/RS485 serial communications for Airborne, Tactical and Shipboard applications \\

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 3 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Functional Block Diagram AGGREGATION MEDIA CONVERTER

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 4 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Connectors NAME Insert Arrangement Function Media Converter Mating PLUG Connector Series 805 Mighty Mouse Pin Connector Electrical Signal, Status and Built In Test (BIT), & Power Series 805, 19-85

85 PIN CONTACTS, #23

Series 805, Plug 805-001-16#19-85SA Or 805-002-16#19-85SA Refer to Glenair Mighty Mouse Catalog for further details

85 SOCKET CONTACTS, #23

Glenair High Density (GHD) Shell 11-04 Fiber Optic Signal Glenair High Density (GHD) Shell 11-04 Glenair High Density (GHD) Plug: 180-122#06-11-4N GHD Alignment sleeve retainer (ASR): 180-122ASR-11-4 GHD genderless terminus for MMF or SMF: 181-056-1260C Note: # = Environmental Class (Material/Finish)

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 5 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Built In Test (BIT) Functionality - Optional Features This media converter can be offered with built in test functionality accessible through a Console Port via Universal Serial Bus 2.0 (USB 2.0) or via RS-232 UART (RXD, TXD) or both options can be made available. Functional block diagram for this is shown below. Universal Serial Bus (2.0) BIT

  • Presents itself as a “Virtual” Communications Port
  • Compatible with Microsoft Windows, Mac, and Linux OS’s.
  • On the computer side, open any terminal application (PuTTY, HyperTERM, TeraTERM, etc.) to communicate with the media converter hardware.
  • Simple “Human Readable” status messages. RS-232 UART (RXD, TXD) BIT
  • Useful for when you are interfacing with an embedded microprocessor or micro controller.
  • Status messages delimited to allow for easy parsing by embedded software. ALARM STATUS MESSAGES Fiber Side Alarm/Status
  • Temperature o -55°C to +90°C, better than 1°C resolution
  • Input Transceiver Voltage Monitor o Range: 2.85V to 3.45V, better than 1.6mV resolution
  • Transmitter Bias Monitor (Reports: Good, Warning, Fault)
  • Transmitter Power Monitor (Reports: Good, Warning, Fault)
  • Receiver Photo Diode Current Monitor (Reports: Good, Warning, Fault)
  • Transmitter Fault Alarm Status
  • Receiver loss of signal (LOS) or signal Detect (SD) Status Unit Identification Information
  • Unit Serial Number
  • Unit Product Code
  • Unit Description

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 6 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount TYPICAL CONSOLE PORT WINDOW (PuTTY)

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 7 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Ratings and Specifications – L VERSION ABSOLUTE MAXIMUM RATINGS Parameter Symbol Min Typ Max Units Notes Storage Temperature Ts -55 +100 °C Supply Voltage Vcc -0.5 45 V 1 second maximum OPERATING CONDITIONS Parameter Symbol Min Typ Max Units Notes Operating Temperature Top -40 +75 °C Supply Voltage Vcc 5 28 36 V Supply Current Icc 100 150 mA @28VDC Power Supply Noise (Peak-Peak) Vcc ripple 200 mV OPTICAL CHARACTERISTICS – TRANSMITTER (3.2 GBPS) Parameter Symbol Min Typ Max Units Notes Optical Output Power POUT -8.5 -4 -3 dBm 1310nm Fabry-Perot Extinction Ratio Er 8 dB Optical Wavelength λOUT 1285 1310 1345 nm Spectral Width Δλ 3.5 nm OPTICAL CHARACTERISTICS – RECEIVER (3.2 GBPS) Parameter Symbol Min Typ Max Units Notes Optical Sensitivity ( Input Power Range) PIN OP -18 0 dBm Min. Sensitivity, BER 10-12, PRBS 2-7-1, 8dB Er PIN_MIN -20 -18 dBm PIN PD, LX10 source Overload, BER 10-12, PRBS 2-7-1 PIN MAX 0 dBm Optical Wavelength λIN 1100 1310 1590 nm

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 8 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Ratings and Specifications – S VERSION ABSOLUTE MAXIMUM RATINGS Parameter Symbol Min Typ Max Units Notes Storage Temperature Ts -55 +100 °C Supply Voltage Vcc -0.5 45 V 1 second maximum OPERATING CONDITIONS Parameter Symbol Min Typ Max Units Notes Operating Temperature Top -40 +75 °C Supply Voltage Vcc 5 28 36 V Supply Current Icc 100 150 mA @28VDC Power Supply Noise (Peak-Peak) Vcc ripple 200 mV OPTICAL CHARACTERISTICS – TRANSMITTER (3.2 GBPS) Parameter Symbol Min Typ Max Units Notes Optical Output Power POUT -9.5 -4 dBm VCSEL, 62.5/125µm MM Extinction Ratio Er 8 dB Optical Wavelength λOUT 830 850 860 nm Spectral Width Δλ 0.85 nm OPTICAL CHARACTERISTICS – RECEIVER (3.2 GBPS) Parameter Symbol Min Typ Max Units Notes Optical Sensitivity (Input Power Range) PIN OP -16 -2 dBm Sensitivity, BER 10-12, PRBS 2-7-1, 8dB Er PIN_MIN -21 -16 dBm PIN PD Overload, BER 10-12, PRBS 2-7-1 PIN MAX -2 -1 dBm Optical Wavelength λ IN 770 850 860 nm

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 9 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Ratings and Specifications - (continued) COMPLIANCE SPECIFICATIONS CHARACTERISTIC Standard Condition Notes Mechanical Shock MIL-STD-810 40g 6-9 ms Mechanical Vibration MIL-STD-810 30g rms ESD MIL-STD-883 Class II 2200V HBM Lightning Strike DO-160G, Section 22 Category: A2J2X No damage, Operate error free before and after application of the pin injection tests. Will operate error free during shielded cable bundle injection tests Conducted Emissions, Power Leads, 10 kHz to 10 MHz MIL-STD-461F CE102 Conducted Susceptibility, Power Leads, 30 Hz to 150KHz MIL-STD-461F CS101 Conducted Susceptibility, Bulk Cable Injection, 10 kHz to 200 MHz MIL-STD-461F CS114 Radiated Susceptibility, Electric Field, 2 MHz to 18 GHz MIL-STD-461F RS103 Flame Resistance MIL-STD-1344 Method 1012 30 seconds Damp Heat MIL-STD-1344 10 cycles 24 hours Eye Safety CDRH and IEC-825 Class 1 Laser Product

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 10 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount OUTLINE DRAWING & PANEL CUT OUT PANEL CUT OUT & Mouting Holes – J1 & J2

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 11 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount FLANGE Mouting Holes Marking Marking Assembly is identified with Manufacture’s Name, Cage Code, Part Number, Date Code and Serial Number in approximate location shown. Drawing and location Not to Scale. Marking will conform to MIL-STD-130 (Arial font, 0.08” minimum height) Glenair 06324 050-501-S-MT00AN 1434 SN 123456

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 12 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Input/Output Definition J1 – ELECTRICAL SIGNAL CONNECTOR PIN FUNCTIONS PIN NAME DESCRIPTION NOTE PIN NAME DESCRIPTION NOTE Series 805 Mighty Mouse Mating face for PIN shown 85X SIZE 23 Contacts

10 Port1_OUT_P Port 1 TX Pos 2 44 Port8_OUT_N Port 8 TX Neg 2

4 Port1_OUT_N Port 1 TX Neg 2 43 Port8_IN_P Port 8 RX Pos 2

3 Port1_IN_P Port 1 RX Pos 2 42 Port8_IN_N Port 8 RX Neg 2

2 Port1_IN_N Port 1 RX Neg 2 82 Port8_GND_422 Port 8 Ground 2

67 Port1_GND_422 Port 1 Ground 39 NC Not Connected

8 NC Not Connected 47 Port9_OUT_P Port 9 TX Pos 2

1 Port2_OUT_P Port 2 TX Pos 2 46 Port9_OUT_N Port 9 TX Neg 2

7 Port2_OUT_N Port 2 TX Neg 2 45 Port9_IN_P Port 9 RX Pos 2

6 Port2_IN_P Port 2 RX Pos 2 55 Port9_IN_N Port 9 RX Neg 2

5 Port2_IN_N Port 2 RX Neg 2 41 Port9_GND_422 Port 9 Ground 2

68 Port2_GND_422 Port 2 Ground 40 NC Not Connected

11 NC Not Connected 54 Port10_OUT_P Port 10 TX Pos 2

9 Port3_OUT_P Port 3 TX Pos 2 53 Port10_OUT_N Port 10 TX Neg 2

16 Port3_OUT_N Port 3 TX Neg 2 52 Port10_IN_P Port 10 RX Pos 2

15 Port3_IN_P Port 3 RX Pos 2 61 Port10_IN_N Port 10 RX Neg 2

14 Port3_IN_N Port 3 RX Neg 2 51 Port10_GND_422 Port 10 Ground 2

80 Port3_GND_422 Port 3 Ground 74 NC Not Connected

12 NC Not Connected 57 Port11_OUT_P Port 11 TX Pos 2

13 Port4_OUT_P Port 4 TX Pos 2 66 Port11_OUT_N Port 11 TX Neg 2

22 Port4_OUT_N Port 4 TX Neg 2 65 Port11_IN_P Port 11 RX Pos 2

21 Port4_IN_P Port 4 RX Pos 2 64 Port11_IN_N Port 11 RX Neg 2

20 Port4_IN_N Port 4 RX Neg 2 56 Port11_GND_422 Port 11 Ground 2

79 Port4_GND_422 Port 4 Ground 2 75 NC Not Connected

27 NC Not Connected 63 Port12_OUT_P Port 12 TX Pos 2

19 Port5_OUT_P Port 5 TX Pos 2 72 Port12_OUT_N Port 12 TX Neg 2

18 Port5_OUT_N Port 5 TX Neg 2 71 Port12_IN_P Port 12 RX Pos 2

17 Port5_IN_P Port 5 RX Pos 2 70 Port12_IN_N Port 12 RX Neg 2

26 Port5_IN_N Port 5 RX Neg 2 62 Port12_GND_422 Port 12 Ground 2

78 Port5_GND_422 Port 5 Ground 2 73 BIT_OUT_P BIT Output TX Pos

29 NC Not Connected 81 BIT_OUT_N BIT Output TX Neg

25 Port6_OUT_P Port 6 TX Pos 2 58 POWER 5-36VDC Input

24 Port6_OUT_N Port 6 TX Neg 2 59 POWER 5-36VDC Input

23 Port6_IN_P Port 6 RX Pos 2 60 POWER 5-36VDC Input

32 Port6_IN_N Port 6 RX Neg 2 48 POWER_RTN Power Return

84 Port6_GND_422 Port 6 Ground 49 POWER_RTN Power Return

30 NC Not Connected 50 POWER_RTN Power Return

28 Port7_OUT_P Port 7 TX Pos 2 38 VBUS USB +5V Input 1

37 Port7_OUT_N Port 7 TX Neg 2 77 USB_D+ USB Data + 1

36 Port7_IN_P Port 7 RX Pos 2 69 USB_D- USB Data - 1

35 Port7_IN_N Port 7 RX Neg 2 31 NC Not Connected

83 Port7_GND_422 Port 7 Ground 2 76 NC Not Connected

33 NC Not Connected 85 NC Not Connected

34 Port8_OUT_P Port 8 TX Pos 2

  1. Built In Test Port, USB2.0 2. Compliant to ANSI TIA/EIA-422 voltage signaling levels; Max rate 6 Mbps.

©2014 Glenair, Inc. REV: 2 US Cage Code 06324 Printed in USA GLENAIR, INC. ∙ 1211 AIR WAY ∙ GLENDALE, CA 91201-2497 ∙ TEL: 818-247-6000 ∙ FAX: 818-500-9912 www.glenair.com PAGE 13 of 13 E-mail: sales@glenair.com 050-501 Copper to Fiber 12 Channel RS422/485 Media Converter Flange Mount Input/Output Definition (continued) J2 OPTICAL CONNECTOR Glenair High Density (GHD) Shell Size 11-4 Fiber Optic connector J2 PIN FUNCTION ASSIGNMENTS PIN NAME DESCRIPTION NOTES 1 NC

2 TX1 Transmitter

4 RX1 Receiver