Motor Protection: Auto Restart/Polarity Protection Insulation Resistance: 10M Ω or over with a DC500V Megger Dielectric Withstand Voltage: AC 700V 1s Allowable Ambient T emperature Range: -10°C ~ +70°C (Operating) -40°C ~ +70°C (Storage) (non-condensing environment) General Specifications DC Axial Fans Characteristic Curves Legacy Part No. 1604KL Outline Panel Cut-Outs inch (mm)Units: 04010KA (40 X 10L) Material Casing : Plastic (Black) UL94V-0 Impeller : Plastic (Black) UL94V-0 Bearing : Ball Bearing Lead Wire : UL1061, AWG26, +Red, -Black Expected Life Failure Rate: 10% 25°C 60,000 Hours Static Pressure Ps (Pa) Air Flow (m3/min) CFM In H2O .06 .12 .19 .26 .32 N M L 8 – R3.0 AIR .09 (2.3) .10 (2.7) NAME PLATE 1.26 (32.0 0.2) 1.57 (40.0 0.3) 1.26 (32.0 0.2) 1.57 (40.0 0.3) .138 4 – (φ3.5) ROTATION .39 (10.0 0.5) 7.87 (200) min Rib Type Only 1.54 (39.0 4– (φ3.5) 1.26 (32.0) 1.52 (38.6) 1.26 (32.0) 1.52 (38.6) .138 INLET SIDE / OUTLET SIDE Rotation: Clockwise Airflow Outlet: Air Out Over Struts *1: Average V alues in Free Air Note: Locked Rotor/Tach A vailable Specifications Rated Operating Current Input Speed Max. Max. Static Noise Mass MODEL LEGACY P/N Voltage Voltage Power Air Flow Pressure (V) (V) (A)*1 (W)*1 (min-1)*1 CFM*1 (m3/min)*1 in H2O (Pa)*1 (dB)*1 (g) NMBTC.COM / 248.919.2250