02S150-C10S3 ROSENBERGER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
RPC-2.92 Calibration Load Plug 02S150-C10S3 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : info@rosenberger.de Page RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG All dimensions are in mm; tolerances according to ISO 2768 m-H Interface According to IEC 61169-35 Mechanically compatible with RPC-3.50 and SMA Documents Material and plating Connector parts Material Plating Center conductor CuBe Gold, min. 1.27 µm, over nick el Outer conductor Stainless steel Passivated Coupling nut Stainless steel Passivated Dielectric PS Substrate Al 2O 3
RPC-2.92 Calibration Load Plug 02S150-C10S3 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : info@rosenberger.de Page RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG Electrical data Frequency range DC to 40 GHz Return loss ≥ 42 dB, DC to 4 GHz ≥ 33 dB, 4 GHz to 18 GHz ≥ 30 dB, 18 GHz to 40 GHz DC Resistance 50 Ω ± 0.25 Ω Power handling ≤ 0.5 W Mechanical data Mating cycles ≥ 500 Maximum torque 1.70 Nm Recommended torque 0.90 Nm Gauge 0.00 mm to 0.03 mm General standard definitions For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour of this calibration standard. The different models, units, and terms used will depend on the VNA type and they will have to be entered into the VNA. All values are based on typical geometry and plating. Offset Z o / Impedance / Z o 50 Ω Offset Delay 0.0000 ps Length (electrical) / Offset Length 0.00 mm Offset Loss 0.00 G Ω/s Loss 0.0000 dB/ GHz Environmental data Operating temperature range 1 +20 °C to +26 °C Rated temperature range of use 2 0 °C to +50 °C Storage temperature range -40 °C to +85 °C RoHS compliant 1 Temperature range over which these specification are valid. 2 This range is underneath and above the operating temperature range, within the calibration load is fully functional and could be used without damage.
RPC-2.92 Calibration Load Plug 02S150-C10S3 Rosenberger Hochfrequenztechnik GmbH & Co. KG P.O.Box 1260 D-84526 Tittmoning Germany www.rosenberger.de Tel. : +49 8684 18-0 Email : info@rosenberger.de Page RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG Declaration of calibration options Factory Calibration Standard delivery for this calibration standard includes a Factory Calibration. The Calibration Certificate issued reports individual calibration results, traceable to national / international standards. Model based standard definitions are reported in an Agilent/Keysight, Rohde & Schwarz and Anritsu compatible VNA format. Accredited Calibration Optional this calibration standard can be delivered with an Accredited Calibration (DAkkS) having the highest confidence in the traceability. The DAkkS Calibration Certificate issued reports individual calibration results in a complex format, traceable to national / international standards. Model based standard definitions are reported in an Agilent/Keysight, Rohde & Schwarz and Anritsu compatible VNA format as well as in a dense data set needed for data based standard definitions. The uncertainties are smaller than in a Factory Calibration. For further, more detailed information see application note AN001 on the Rosenberger homepage. Calibration interval Recommendation 12 months Weight 8.6 g/pce Draft Date Approved Date Rev. Engineering change n umber Name Date While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warr anty on our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our products, we reserve the right to make changes judged to be necessary.