TRI15 TRACOPOWER

Document overview

  • PDF pages: 4

Technical content

Page 1

DC/DC Converter

PDF page 1 diagram
  • Reinforced I/O-isolation 4200 VAC rated for 1000 VAC working voltage
  • Ultra-high isolation peak voltage 8000 VDC (1s)
  • Common Mode Transient Immunity (dv/dt) 15 kV/µs
  • Operating temperature range -40 to

UL 62368-1 IEC 62368-1

+85°C

The new TRI 15 is a high isolation, regulated 15 Watt DC/DC converter series

  • Low no-load power consumption 240 –

which comes in a compact 2”x1” package. The core characteristic of the TRI 15

480 mW

series is a sophisticated reinforced isolation system which is able to withstand high test voltages (8000 VDC for 1s and 4200 VAC for 60s) and working volt-

  • Internal EN 55032 class A filter

ages (1000 VACrms). Complementing this isolation characteristic is a high

  • High efficiency up to 90%

Common Mode Transient Immunity of 15 kV/µs. The new design allows to fully integrate an EN 55032 class A filter and greatly reduces the no-load power

  • 2:1 input voltage range: 9-18, 18-36,

consumption. High efficiencies up to 90% allow safe operation from –40°C to

36-75 VDC

+65°C without derating and up to +85°C with derating. All models have a wide 2:1 input voltage range and precisely regulated, isolated output voltages. With

  • Protection against overload, overvoltage

the latest IT safety certifications (IEC/EN/UL 62368-1) the TRI 15 series is the

and short circuit

perfect choice for many demanding applications in the industrial, transportation

  • 3-year product warranty

and instrumentation sectors.

Models

Order Code Input Voltage Range Output 1 Vnom Imax Output 2 Vnom Imax Efficiency typ.
TRI 15-1211 TRI 15-1212 TRI 15-1213 TRI 15-1215 TRI 15-1222 TRI 15-1223 9 - 18 VDC (12 VDC nom.) 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3'000 mA 1'250 mA 1'000 mA 625 mA 625 mA 500 mA –12 VDC –15 VDC 625 mA 500 mA 85 % 88 % 88 % 88 % 88 % 89 %
TRI 15-2411 TRI 15-2412 TRI 15-2413 TRI 15-2415 TRI 15-2422 TRI 15-2423 18 - 36 VDC (24 VDC nom.) 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3'000 mA 1'250 mA 1'000 mA 625 mA 625 mA 500 mA –12 VDC –15 VDC 625 mA 500 mA 87 % 88 % 89 % 90 % 90 % 89 %
TRI 15-4811 TRI 15-4812 TRI 15-4813 TRI 15-4815 TRI 15-4822 TRI 15-4823 36 - 75 VDC (48 VDC nom.) 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 3'000 mA 1'250 mA 1'000 mA 625 mA 625 mA 500 mA –12 VDC –15 VDC 625 mA 500 mA 87 % 87 % 90 % 89 % 89 % 88 %

Page 1 / 4

Page 2

Input Specifications

Input Current

  • At no load
  • At full load

Surge Voltage

Under Voltage Lockout

Reflected Ripple Current

Recommended Input Fuse

Input Filter

Output Specifications

Voltage Set Accuracy Regulation

  • Input Variation (Vmin - Vmax)
  • Load Variation (0 - 100%)
  • Voltage Balance (symmetrical load)

Ripple and Noise

  • single output

(20 MHz Bandwidth)

  • dual output

Capacitive Load

  • single output
  • dual output

Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response

  • Response Deviation - Response Time

Safety Specifications

Safety Standards

  • IT / Multimedia Equipment
  • Certification Documents

12 Vin models: 20 mA typ. 24 Vin models: 15 mA typ. 48 Vin models: 10 mA typ. 12 Vin models: 1'430 mA typ. 24 Vin models: 706 mA typ. 48 Vin models: 355 mA typ. 12 Vin models: 25 VDC max. (100 ms max.) 24 Vin models: 50 VDC max. (100 ms max.) 48 Vin models: 100 VDC max. (100 ms max.) 12 Vin models: 7.5 VDC typ. 24 Vin models: 15 VDC typ. 48 Vin models: 33 VDC typ. 12 Vin models: 100 mAp-p typ. 24 Vin models: 50 mAp-p typ. 48 Vin models: 30 mAp-p typ.

(The need of an external fuse has to be assessed in the final application.) Internal Pi-Type

±1% max.

single output models: 0.5% max. dual output models: 0.5% max. single output models: 0.5% max. dual output models: 1% max. (Output 1)

1% max. (Output 2)

dual output models: 2% max.

5.1 Vout models: 50 mVp-p typ. (w/ 4.7 µF MLCC) 12 Vout models: 100 mVp-p typ. (w/ 4.7 µF MLCC) 15 Vout models: 100 mVp-p typ. (w/ 4.7 µF MLCC) 24 Vout models: 150 mVp-p typ. (w/ 4.7 µF MLCC) 12 / -12 Vout models: 100 / 100 mVp-p typ. (w/ 4.7 µF MLCC) 15 / -15 Vout models: 100 / 100 mVp-p typ. (w/ 4.7 µF MLCC) 5.1 Vout models: 5'100 µF max. 12 Vout models: 870 µF max. 15 Vout models: 560 µF max. 24 Vout models: 220 µF max. 12 / -12 Vout models: 440 / 440 µF max. 15 / -15 Vout models: 280 / 280 µF max.

Not required ±0.02 %/K max. 30 ms max. Continuous, Automatic recovery 150% typ. of Iout max. 120% typ. of Vout nom. 5% max. (75% to 100% Load Step) 300 µs max. (75% to 100% Load Step)

EN 62368-1 IEC 62368-1 UL 62368-1 www.tracopower.com/overview/tri15

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 2 / 4

Page 3

Pollution Degree Over Voltage Category

EMC Specifications

EMI Emissions

  • Conducted Emissions
  • Radiated Emissions

PD 2 OVC II

EN 55032 class A (internal filter) EN 55032 class B (with external filter) FCC Part 15 class A (internal filter) EN 55032 class A (with external filter) FCC Part 15 class A (with external filter)

External filter proposal: www.tracopower.com/overview/tri15

EMS Immunity

  • Electrostatic Discharge
  • RF Electromagnetic Field - EFT (Burst) / Surge

EN 55024 (IT Equipment) Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A

Ext. input component: 12 & 24 Vin models: KY 560 µF || V15P8-M3

  • Conducted RF Disturbances - PF Magnetic Field

General Specifications

Relative Humidity Temperature Ranges

  • Operating Temperature - Case Temperature - Storage Temperature

Power Derating

  • High Temperature

48 Vin models: KY 560 µF || V15P10 EN 61000-4-6, 10 Vrms, perf. criteria A Continuous: EN 61000-4-8, 100 A/m, perf. criteria A

95% max. (non condensing) –40°C to +85°C +95°C max. –50°C to +125°C Depending on model

See application note: www.tracopower.com/overview/tri15

Cooling System Altitude During Operation Switching Frequency Insulation System Working Voltage (rated) Isolation Test Voltage

  • Input to Output, 60 s - Input to Output, 1 s

Isolation Resistance

  • Input to Output, 500 VDC

Isolation Capacitance

  • Input to Output, 100 kHz, 1 V

Common Mode Transient Immunity Reliability

  • Calculated MTBF

Washing Process

Housing Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile

Weight Thermal Impedance

  • Case to Ambient

Natural convection (20 LFM) 4'000 m max. 285 kHz typ. (PWM) Reinforced Insulation 1'000 VAC 4'200 VAC 8'000 VDC 10'000 MΩ min. 80 pF max. 15 kV/µs min.

1'428'000 h (MIL-HDBK-217F, ground benign) According to Cleaning Guideline www.tracopower.com/info/cleaning.pdf Plastic (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Copper Alloy (C6801) Nickel (2 - 4 µm) Tin (5 - 7 µm), matte Plastic Case PCB Mount THD (Through-Hole Device) 2" x 1" Wave Soldering 260°C / 10 s max. 30 g 13 K/W typ.

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 3 / 4

Page 4

Environmental Compliance

  • REACH Declaration
  • RoHS Declaration

Supporting Documents

Overview Link (for additional Documents)

Outline Dimensions

PDF page 4 diagram

www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.)

www.tracopower.com/overview/tri15

Pinout
Pin Single Output Dual Output
1 +Vin (Vcc) +Vin (Vcc)
2 –Vin (GND) –Vin (GND)
3 +Vout +Vout
4 No pin Common
5 –Vout –Vout
PDF page 4 diagram

Dimensions in mm (inch) Tolerances: x.x ±0.5 (x.xx ±0.02) x.xx ±0.25 (x.xxx ±0.01) Pin diameter tolerances: x.x ±0.05 (x.xx ±0.002)

© Copyright 2023 Traco Electronic AG

Specifications can be changed without notice.

Rev. March 17, 2023 Page 4 / 4