TRI10 TRACOPOWER

Document overview

  • PDF pages: 4

Technical content

Page 1

DC/DC Converter

PDF page 1 diagram
  • Reinforced I/O-isolation 5000 VAC rated for 1000 VAC working voltage
  • Ultra-high isolation peak voltage 9000 VDC (1s)
  • Common Mode Transient Immunity (dv/dt) 15 kV/µs
  • Operating temperature range -40 to

UL 62368-1 IEC 62368-1

+85°C

The new TRI 10 is a high isolation, regulated 10 Watt DC/DC converter series

  • Low no-load power consumption 144 –

which comes in a compact DIP-24 package. The core characteristic of the TRI

288 mW

10 series is a sophisticated reinforced isolation system which is able to withstand high test voltages (9000 VDC for 1s and 5000 VAC for 60s) and working

  • Internal EN 55032 class A filter

voltages (1000 VACrms). Complementing this isolation characteristic is a high

  • High efficiency up to 88%

Common Mode Transient Immunity of 15 kV/µs. The new design allows to fully integrate an EN 55032 class A filter and greatly reduces the no-load power

  • 2:1 input voltage range: 9-18, 18-36,

consumption. High efficiencies up to 88% allow safe operation from –40°C to

36-75 VDC

+65°C without derating and up to +85°C with derating. All models have a wide 2:1 input voltage range and precisely regulated, isolated output voltages. With

  • Protection against overload, overvoltage

the latest IT safety certifications (IEC/EN/UL 62368-1) the TRI 10 series is the

and short circuit

perfect choice for many demanding applications in the industrial, transportation

  • 3-year product warranty

and instrumentation sectors.

Models

Order Code Input Voltage Range Output 1 Vnom Imax Output 2 Vnom Imax Efficiency typ.
TRI 10-1210 TRI 10-1211 TRI 10-1212 TRI 10-1213 TRI 10-1215 TRI 10-1222 TRI 10-1223 9 - 18 VDC (12 VDC nom.) 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA –12 VDC –15 VDC 416 mA 333 mA 81 % 83 % 86 % 88 % 88 % 88 % 87 %
TRI 10-2410 TRI 10-2411 TRI 10-2412 TRI 10-2413 TRI 10-2415 TRI 10-2422 TRI 10-2423 18 - 36 VDC (24 VDC nom.) 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA –12 VDC –15 VDC 416 mA 333 mA 81 % 84 % 87 % 88 % 88 % 88 % 87 %
TRI 10-4810 TRI 10-4811 TRI 10-4812 TRI 10-4813 TRI 10-4815 TRI 10-4822 TRI 10-4823 36 - 75 VDC (48 VDC nom.) 3.3 VDC 5.1 VDC 12 VDC 15 VDC 24 VDC +12 VDC +15 VDC 2'700 mA 2'000 mA 833 mA 666 mA 416 mA 416 mA 333 mA –12 VDC –15 VDC 416 mA 333 mA 81 % 84 % 87 % 88 % 87 % 87 % 87 %

Page 1 / 4

Page 2

Input Specifications

Input Current

  • At no load
  • At full load

Surge Voltage

Under Voltage Lockout

Recommended Input Fuse

Input Filter

Output Specifications

Voltage Set Accuracy Regulation

  • Input Variation (Vmin - Vmax)
  • Load Variation (0 - 100%)
  • Voltage Balance (symmetrical load) - Cross Regulation (25% / 100% asym. load)

Ripple and Noise

  • 20 MHz Bandwidth

Capacitive Load

  • single output
  • dual output

Minimum Load Temperature Coefficient Start-up Time Short Circuit Protection Output Current Limitation

Overvoltage Protection Transient Response

  • Response Deviation - Response Time

Safety Specifications

Safety Standards

  • IT / Multimedia Equipment
  • Certification Documents

Pollution Degree Over Voltage Category

12 Vin models: 12 mA typ. 24 Vin models: 8 mA typ. 48 Vin models: 6 mA typ. 12 Vin models: 960 mA typ. 24 Vin models: 480 mA typ. 48 Vin models: 240 mA typ. 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) 12 Vin models: 7 VDC min. / 8 VDC typ. 24 Vin models: 15 VDC min. / 16 VDC typ. 48 Vin models: 31 VDC min. / 33 VDC typ.

(The need of an external fuse has to be assessed in the final application.) Internal Pi-Type

±1% max.

single output models: 0.5% max. dual output models: 0.5% max. single output models: 0.5% max. dual output models: 1% max. (Output 1)

1% max. (Output 2)

dual output models: 2% max.

dual output models: 5% max.

50 mVp-p typ. (w/ 10 µF MLCC) 70 mVp-p max. (w/ 10 µF MLCC)

3.3 Vout models: 4'700 µF max. 5.1 Vout models: 3'300 µF max. 12 Vout models: 560 µF max. 15 Vout models: 360 µF max. 24 Vout models: 140 µF max. 12 / -12 Vout models: 280 / 280 µF max. 15 / -15 Vout models: 180 / 180 µF max.

Not required ±0.02 %/K max. 30 ms typ. / 60 ms max. Continuous, Automatic recovery 190% max. of Iout max. 150% typ. of Iout max. 125% typ. of Vout nom. 5% max. (75% to 100% Load Step) 300 µs typ. (75% to 100% Load Step)

EN 62368-1 IEC 62368-1 UL 62368-1 www.tracopower.com/overview/tri10 PD 2 OVC II

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 2 / 4

Page 3

EMC Specifications

EMI Emissions

  • Conducted Emissions
  • Radiated Emissions

EN 55032 class A (internal filter) EN 55032 class B (with external filter) FCC Part 15 class A (internal filter) EN 55032 class A (internal filter) FCC Part 15 class A (internal filter)

External filter proposal: www.tracopower.com/overview/tri10

EMS Immunity

  • Electrostatic Discharge
  • RF Electromagnetic Field - EFT (Burst) / Surge

EN 55024 (IT Equipment) EN 55035 (Multimedia) Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A EN 61000-4-3, 10 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A

Ext. input component: KY 470 µF / 100 V

  • Conducted RF Disturbances - PF Magnetic Field

General Specifications

Relative Humidity Temperature Ranges

  • Operating Temperature - Case Temperature - Storage Temperature

Power Derating

  • High Temperature

EN 61000-4-6, 10 Vrms, perf. criteria A Continuous: EN 61000-4-8, 100 A/m, perf. criteria A

95% max. (non condensing) –40°C to +85°C +105°C max. –50°C to +125°C Depending on model

See application note: www.tracopower.com/overview/tri10

Cooling System Altitude During Operation Switching Frequency

Insulation System Working Voltage (rated) Isolation Test Voltage

  • Input to Output, 60 s - Input to Output, 1 s

Isolation Resistance

  • Input to Output, 500 VDC

Isolation Capacitance

  • Input to Output, 100 kHz, 1 V

Common Mode Transient Immunity Reliability

  • Calculated MTBF

Washing Process

Natural convection (20 LFM) 5'000 m max. 200 - 280 kHz (PWM) 240 kHz typ. (PWM) Reinforced Insulation 1'000 VAC 5'000 VAC 9'000 VDC 10'000 MΩ min. 20 pF max. 15 kV/µs min.

3'817'000 h (MIL-HDBK-217F, ground benign) Allowed (hermetical product)

See Cleaning Guideline:

Housing Material Potting Material Pin Material Pin Foundation Plating Pin Surface Plating Housing Type Mounting Type Connection Type Footprint Type Soldering Profile

Weight

www.tracopower.com/info/cleaning.pdf Plastic resin (UL 94 V-0 rated) Silicone (UL 94 V-0 rated) Copper Alloy (C6801) Nickel (2 - 4 µm) Tin (3 - 5 µm), matte Plastic Case PCB Mount THD (Through-Hole Device) DIP24 Wave Soldering 260°C / 10 s max. 16 g

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 3 / 4

Page 4

Environmental Compliance

  • REACH Declaration
  • RoHS Declaration

Supporting Documents

Overview Link (for additional Documents)

Outline Dimensions

PDF page 4 diagram

www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.)

www.tracopower.com/overview/tri10

Pinout
Pin Single Output Dual Output
1 +Vin (Vcc) +Vin (Vcc)
11 No pin Common
12 –Vout No pin
13 +Vout –Vout
15 No pin +Vout
23 –Vin (GND) –Vin (GND)
24 –Vin (GND) –Vin (GND)
PDF page 4 diagram

Dimensions in mm (inch) Tolerances: X.X ±0.5 (X.XX ±0.02) X.XX ±0.25 (X.XXX ±0.01) Pin Ø 0.6 ±0.05 (0.02 ±0.002)

© Copyright 2022 Traco Electronic AG

Specifications can be changed without notice.

Rev. November 30, 2022

Page 4 / 4