TPI100A TRACOPOWER

Document overview

  • PDF pages: 5

Technical content

Page 1

AC/DC Industrial Power Supply

PDF page 1 diagram
  • Highest power density 100 W open frame power supply in 2” x 3” package
  • I/O reinforced isolation 3000 VDC
  • Ready to meet ErP directive, < 0.3 W no load power consumption
  • Highest efficiency 91% - 92% across 10% - 100% load range
  • Active power factor correction > 95
  • Protection class II prepared
  • Operating up to 5000 m altitude
  • Adjustable output voltage

UL 62368-1 IEC 62368-1

  • 3-year product warranty

The TPI 100A Series of 100 Watt AC/DC power supplies features a 3000 VAC I/O reinforced isolation. Excellent efficiency of up to 92% allows a high power density for the standard 2.0” x 3.0” packaging format. The full load operating temperature range is –40°C to +50°C while it goes up to 80°C with load derating. The power supplies are designed to meet the ErP directive (< 0.3 W no load power consumption). They come with an active power factor correction and the EMC characteristic is dedicated for applications in industrial and do- mestic fields. High reliability is provided by use of industrial quality grade components and an excellent thermal management. It makes the products an ideal

solution for any demanding industrial devices and space critical applications.

Models

Order Code Output Power max. Output Voltage nom. (adjustable) Output Current max. Efficiency typ.
TPI 100-112A-J TPI 100-115A-J TPI 100-124A-J TPI 100-128A-J TPI 100-136A-J TPI 100-148A-J 100 W 12 VDC (10.8 - 13.2 VDC) 15 VDC (13.5 - 16.5 VDC) 24 VDC (21.6 - 26.4 VDC) 28 VDC (25.2 - 30.8 VDC) 36 VDC (32.4 - 39.6 VDC) 48 VDC (43.2 - 52.8 VDC) 8'340 mA 6'670 mA 4'170 mA 3'580 mA 2'780 mA 2'090 mA 91 % 92 % 92 % 92 % 91 % 91 %

Page 1 / 5

Page 2

Input Specifications

Input Voltage

  • AC Range
  • DC Range

Input Frequency

Input Current

  • Full Load & Vin = 230 VAC - Full Load & Vin = 115 VAC

Power Consumption

  • No load & Vin = 230 VAC - No load & Vin = 115 VAC

Input Inrush Current

  • At 230 VAC - At 115 VAC

Power Factor

  • At 230 VAC - At 115 VAC

Input Protection Recommended Input Fuse

Output Specifications

Output Voltage Adjustment

Voltage Set Accuracy Regulation

  • Input Variation (Vmin - Vmax) - Load Variation (0 - 100%)

Ripple and Noise (20 MHz Bandwidth)

Capacitive Load

Minimum Load Temperature Coefficient Hold-up Time

  • At 230 VAC - At 115 VAC

Start-up Time

  • At 230 VAC - At 115 VAC

Short Circuit Protection Output Current Limitation Overvoltage Protection Transient Response

  • Response Deviation - Response Time

Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: +DC: L / –DC: N Operational Range: 47 - 440 Hz Certified: 50/60 Hz 550 mA max. 1'150 mA max. 300 mW max. (Ready to meet ErP directive) 300 mW max. 100 A max. 55 A max. 0.95 min. 0.95 min. T 3.15 A / 250 VAC (Internal Fuse in L & N) (The need of an external fuse has to be assessed in the final application.)

±10% (By trim potentiometer) Output power must not exceed rated power! ±1% max. 0.2% max. 0.5% max.

12 VDC model: 120 mVp-p typ. (w/ 10 µF X7R) 15 VDC model: 150 mVp-p typ. (w/ 10 µF X7R) 24 VDC model: 160 mVp-p typ. (w/ 1 µF X7R) 28 VDC model: 180 mVp-p typ. (w/ 1 µF X7R) 36 VDC model: 190 mVp-p typ. (w/ 1 µF X7R) 48 VDC model: 340 mVp-p typ. (w/ 0.1 µF X7R) 12 VDC model: 6'950 µF max. 15 VDC model: 4'450 µF max. 24 VDC model: 1'750 µF max. 28 VDC model: 1'280 µF max. 36 VDC model: 770 µF max. 48 VDC model: 430 µF max.

Not required ±0.02 %/K max. 22 ms min. 22 ms min. 1'000 ms max. 1'000 ms max. Continuous, Automatic recovery 115 - 150% of Iout max. 115 - 135% of Vout nom. 3% max. (50% to 75% Load Step) 500 µs typ. (50% to 75% Load Step)

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 2 / 5

Page 3

Safety Specifications

Safety Standards

  • IT / Multimedia Equipment
  • Certification Documents

Protection Class Pollution Degree Over Voltage Category

EMC Specifications

EMI Emissions

  • Conducted Emissions
  • Radiated Emissions
  • Harmonic Current Emissions
  • Voltage Fluctuations & Flicker

EMS Immunity

  • Electrostatic Discharge
  • RF Electromagnetic Field - EFT (Burst) / Surge
  • Conducted RF Disturbances - PF Magnetic Field - Voltage Dips & Interruptions

General Specifications

Relative Humidity Temperature Ranges

  • Operating Temperature - Storage Temperature

Power Derating

  • High Temperature - Low Input Voltage

EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 www.tracopower.com/overview/tpi100a Class I & II (Prepared): Reinforced Insulation PD 2 OVC II

EN 61000-6-4 (Generic Industrial) EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) EN 55011 class A (internal filter) EN 55032 class A (internal filter) FCC Part 15 class A (internal filter) EN 61000-3-2, class A EN 61000-3-2, class D EN 61000-3-3 EN 55024 (IT Equipment) EN 55035 (Multimedia) Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A EN 61000-4-3, 20 V/m, perf. criteria A EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A L to PE: EN 61000-4-5, ±2 kV, perf. criteria A EN 61000-4-6, 20 Vrms, perf. criteria A Continuous: EN 61000-4-8, 10 A/m, perf. criteria A

230 VAC / 50 Hz: EN 61000-4-11

30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 250 periods, perf. criteria B

115 VAC / 60 Hz: EN 61000-4-11

30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 250 periods, perf. criteria B

95% max. (non condensing) –40°C to +80°C –40°C to +85°C (-40°C startup: 80% load max. at Vin >100 VAC -40°C startup: 100% load max. at Vin >200 VAC) Depending on model 1.33 %/V below 100 VAC

See application note: www.tracopower.com/overview/tpi100a

Cooling System Altitude During Operation Switching Frequency Insulation System Working Voltage (rated)

Natural convection (20 LFM) 5'000 m max. 45 - 75 kHz (PWM QR) Reinforced Insulation 344 VAC

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 3 / 5

Page 4

Isolation Test Voltage

  • Input to Output, 60 s - Input to Case or PE, 60 s - Output to Case or PE, 60 s

Isolation Resistance

  • Input to Output, 500 VDC

Leakage Current

  • Touch Current

(at 264 VAC) Reliability

  • Calculated MTBF

Environment

  • Vibration
  • Mechanical Shock

Housing Type Mounting Type Connection Type Weight Environmental Compliance - REACH Declaration

  • RoHS Declaration

Supporting Documents

Overview Link (for additional Documents)

3'000 VAC 1'500 VAC 1'500 VAC 100 MΩ min. 300 µA max.

790'000 h (MIL-HDBK-217F, ground benign) IEC 60068-2-6 1 g, 3 axis, sine sweep, 10-55 Hz, 1 oct/min IEC 60068-2-27 10 g, 3 axis, half sine, 11 ms 20 g, 3 axis, 3 shocks Open Frame Chassis Mount Pin Connector 156 g www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.)

www.tracopower.com/overview/tpi100a

All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.

Page 4 / 5

Page 5

Outline Dimensions

PDF page 5 diagram
PDF page 5 diagram

Dimension in mm, () = inch Tolerances: x.x ±0.50 (±0.02) x.xx ±0.25 (±0.01)

© Copyright 2023 Traco Electronic AG

Pin connectors
Input (CON1) Output (CON2)
Pin 1 Function Line Pin* 1,2 Function –Vout
3 Neutral 3,4 +Vout

\*Terminal rated for 10 A max. (at higher current connection has to be split)

CON1: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-3N

CON2: JST series mates with JST crimp terminal: SVH-21T-P1.1 and terminal housing: VHR-4N

Specifications can be changed without notice.

Rev. March 16, 2023 Page 5 / 5