TP100 ASTRODYNE
Document overview
- PDF pages: 4
Technical content
Page 1

TP100 series
100W Triple Output with PFC Function
Universal AC input

Built-in active PFC function, PF >0.94
Protections: Short circuit / Overload / Over voltage
Fixed switching frequency at 100KHz
Free air cooling convection
Model Number Output Volts Output Amps Ripple & Noise Load Reg Volt Tolerance
Min Load
TRIPLE OUTPUT
TP100-A
5 Volts(DC) 10 Amps 100mVpk-pk
±3.0%
±3.0%
3.0~15Amps
12 Volts(DC)
4.0 Amps 120mVpk-pk
±6.0%
±7.0%
0.4~5.0Amps
-5 Volts(DC)
0.6 Amps 100mVpk-pk
±4.0%
±6.0%
0~1.0Amps
TP100-B
5 Volts(DC)
10 Amps 100mVpk-pk
±3.0%
±3.0%
3.0~15Amps
12 Volts(DC)
4.0 Amps 120mVpk-pk
±6.0%
±6.0%
0.4~5.0Amps
-12 Volts(DC)
0.6 Amps 100mVpk-pk
±4.0%
±6.0%
0~1.0Amps
TP100-C
5 Volts(DC)
10 Amps 100mVpk-pk
±3.0%
±3.0%
3.0~15Amps
15 Volts(DC)
3.0 Amps 150mVpk-pk
±6.0%
+10,-6%
0.4~4.0Amps
-15 Volts(DC)
0.6Amps 100mVpk-pk
±4.0%
±6.0%
0~1.0Amps
TP100-D
5 Volts(DC)
10 Amps 100mVpk-pk
±3.0%
±3.0%
3.0~15Amps
24 Volts(DC)
2.0 Amps 150mVpk-pk
±6.0%
±8.0%
0.4~3.0Amps
12 Volts(DC)
0.6 Amps 100mVpk-pk
±4.0%
±6.0%
0~1.0Amps
Page 2

100W Triple Output with PFC Function
INPUT SPECIFICATIONS
Input Voltage Range (Note 3) 90-264VAC / 127-370 Volts(DC) Frequency Range
47- 63 Hz
Inrush Current, typ: (cold start) ≤ 40Amps @ 230VAC Input Current
1.5 Amps max @ 115VAC 0.75 Amps max @ 230VAC
Leakage current
< 3.5mA / 240 VAC
Power Factor @ FL
PF > 0.94/230VAC >0.98/115VAC
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Line Regulation
±1.0%
Load Regulation
See Selection Chart
Voltage Tolerance (Note 2)
See Selection Chart
Ripple/Noise (Note 1)
See Selection Chart
Hold Up Time @ FL
24mS/230VAC, 24mS/115VAC
Setup, Rise Time @ FL
800mS, 60mS/230VAC 800mS, 60mS/115VAC
Over Voltage Protection
5Volts(DC) only: 5.75~6.75Volts(DC) Shutdown o/p voltage, re-power
Over Current Protection
105~150% rated ourtput power Shutdown o/p voltage, auto recover
Over Temperature Protecion
95°C ±5°C (TSW1) Shutdown o/p voltage, auto recover
DC Voltage Adjust
5Volts(DC) only: 4.5~5.5Volts(DC)
GENERAL SPECIFICATIONS
Safety
UL60950-1 TUV EN60950-1 approved
Insulation Resistance
≥ 100MΩ / 500Volts(DC)
EMI
Compliance to EN55022 (CISPR22) Class B
Harmonic Current
Compliance to EN61000-3-2,-3
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
TP100 series
Efficiency 77% typ. Isolation
3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground 1min
EMS
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 light industry level, criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -10°C to +60°C (See Derate Curve) Storage Temperature -20°C to +85°C, 10~95% RH Relative Humidity 20 to +90% RH non cond Temperature Coefficient ±0.03% / °C (0-50°C) MTBF 170.1KHrs min, MIL-HDBK-217F (25°C) Vibration 10~500Hz, 2G10min./1cycle, period for
60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size Millimeters
199 x 99 x 50
Inches
7.84” x 3.90” x 1.97”
Weight
27.28 oz (830g)
NOTE
- Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltages. Please check the derating curve for more details.
Page 3

TP100 series
100W Triple Output with PFC Function

Page 4

TP100 series
100W Triple Output with PFC Function