TP100 ASTRODYNE

Document overview

  • PDF pages: 4

Technical content

Page 1

PDF page 1 diagram

TP100 series

100W Triple Output with PFC Function

Universal AC input

PDF page 1 diagram

Built-in active PFC function, PF >0.94

Protections: Short circuit / Overload / Over voltage

Fixed switching frequency at 100KHz

Free air cooling convection

Model Number Output Volts Output Amps Ripple & Noise Load Reg Volt Tolerance

Min Load

TRIPLE OUTPUT

TP100-A

5 Volts(DC) 10 Amps 100mVpk-pk

±3.0%

±3.0%

3.0~15Amps

12 Volts(DC)

4.0 Amps 120mVpk-pk

±6.0%

±7.0%

0.4~5.0Amps

-5 Volts(DC)

0.6 Amps 100mVpk-pk

±4.0%

±6.0%

0~1.0Amps

TP100-B

5 Volts(DC)

10 Amps 100mVpk-pk

±3.0%

±3.0%

3.0~15Amps

12 Volts(DC)

4.0 Amps 120mVpk-pk

±6.0%

±6.0%

0.4~5.0Amps

-12 Volts(DC)

0.6 Amps 100mVpk-pk

±4.0%

±6.0%

0~1.0Amps

TP100-C

5 Volts(DC)

10 Amps 100mVpk-pk

±3.0%

±3.0%

3.0~15Amps

15 Volts(DC)

3.0 Amps 150mVpk-pk

±6.0%

+10,-6%

0.4~4.0Amps

-15 Volts(DC)

0.6Amps 100mVpk-pk

±4.0%

±6.0%

0~1.0Amps

TP100-D

5 Volts(DC)

10 Amps 100mVpk-pk

±3.0%

±3.0%

3.0~15Amps

24 Volts(DC)

2.0 Amps 150mVpk-pk

±6.0%

±8.0%

0.4~3.0Amps

12 Volts(DC)

0.6 Amps 100mVpk-pk

±4.0%

±6.0%

0~1.0Amps

Page 2

PDF page 2 diagram

100W Triple Output with PFC Function

INPUT SPECIFICATIONS

Input Voltage Range (Note 3) 90-264VAC / 127-370 Volts(DC) Frequency Range

47- 63 Hz

Inrush Current, typ: (cold start) ≤ 40Amps @ 230VAC Input Current

1.5 Amps max @ 115VAC 0.75 Amps max @ 230VAC

Leakage current

< 3.5mA / 240 VAC

Power Factor @ FL

PF > 0.94/230VAC >0.98/115VAC

OUTPUT SPECIFICATIONS

Voltage and Current

See Selection Chart

Line Regulation

±1.0%

Load Regulation

See Selection Chart

Voltage Tolerance (Note 2)

See Selection Chart

Ripple/Noise (Note 1)

See Selection Chart

Hold Up Time @ FL

24mS/230VAC, 24mS/115VAC

Setup, Rise Time @ FL

800mS, 60mS/230VAC 800mS, 60mS/115VAC

Over Voltage Protection

5Volts(DC) only: 5.75~6.75Volts(DC) Shutdown o/p voltage, re-power

Over Current Protection

105~150% rated ourtput power Shutdown o/p voltage, auto recover

Over Temperature Protecion

95°C ±5°C (TSW1) Shutdown o/p voltage, auto recover

DC Voltage Adjust

5Volts(DC) only: 4.5~5.5Volts(DC)

GENERAL SPECIFICATIONS

Safety

UL60950-1 TUV EN60950-1 approved

Insulation Resistance

≥ 100MΩ / 500Volts(DC)

EMI

Compliance to EN55022 (CISPR22) Class B

Harmonic Current

Compliance to EN61000-3-2,-3

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

TP100 series

Efficiency 77% typ. Isolation

3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground 1min

EMS

Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 light industry level, criteria A

ENVIRONMENTAL SPECIFICATIONS

Oper. Temperature -10°C to +60°C (See Derate Curve) Storage Temperature -20°C to +85°C, 10~95% RH Relative Humidity 20 to +90% RH non cond Temperature Coefficient ±0.03% / °C (0-50°C) MTBF 170.1KHrs min, MIL-HDBK-217F (25°C) Vibration 10~500Hz, 2G10min./1cycle, period for

60min. each along X, Y, Z axes

PHYSICAL SPECIFICATIONS

Size Millimeters

199 x 99 x 50

Inches

7.84” x 3.90” x 1.97”

Weight

27.28 oz (830g)

NOTE

  1. Ripple and Noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47 uf parallel capacitor. 2. Tolerance: includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltages. Please check the derating curve for more details.

Page 3

PDF page 3 diagram

TP100 series

100W Triple Output with PFC Function

PDF page 3 diagram

Page 4

PDF page 4 diagram

TP100 series

100W Triple Output with PFC Function

PDF page 4 diagram
PDF page 4 diagram