TMX W365 SAW Bandpass Filter – WCDMA Rx – RF Specification (Rev 1)
SAW Bandpass Filter – WCDMA Rx – RF Specification (Rev 1) October 25th, 2005
Features
q 2140 MHz Center Frequency q 60 MHz useable Passband q 50 Ohms Single Input / 200 Ohms Balanced Configuration q Ceramic Package for Surface Mounted Technology Package Drawing & Pin out The product is in conformance with the European RoHs Regulation 2002/95. Pin Configuration Input G Output C, D Case ground A, B, E, F
SAW Bandpass Filter – WCDMA Rx – RF Specification (Rev 1) October 25th, 2005 Technical Characteristics Reference Temperature : +25°C Electrical Parameters Unit Minimum Typical (1) Maximum Source Impedance (single ended) Ω - 50 - Load Impedance (balanced drive) Ω - 200(2) - Center Frequency fo MHz - 2140 - Bandwidth at – 3 dB MHz 60 - - Absolute attenuation
180 MHz to 200 MHz dB 60 85 -
200 MHz to 1000 MHz dB 50 58 -
1000 MHz to 1880 MHz dB 29 36
1880 MHz to 1980 MHz dB 26 32
1980 MHz to 2050 MHz dB 22 28
2050 MHz to 2255 MHz dB 13 20
2255 MHz to 2300 MHz dB 19 25 -
2300 MHz to 2490 MHz dB 22 26 -
2490 MHz to 2550 MHz dB 30 39 -
2550 MHz to 3200 MHz dB 32 36 -
3200 MHz to 6000 MHz dB 38 49 -
Insertion Loss within 2110 MHz ~ 2170 MHz dB - 3.1 4.1 Symmetry in band (referenced to the matched operating condition) Output amplitude balance (|S31 / S21|) within 2110 MHz ~ 2170 MHz dB -2.9 0 1.4 Output phase balance (? (S31) – ? (S21)+180°) within 2110 MHz ~ 2170 MHz degree -10 0 15 Input VSWR within 2110 MHz ~ 2170 MHz - 1.7 2.4 Output VSWR within 2110 MHz ~ 2170 MHz - 1.8 2.4 Ripple within 2110 MHz ~ 2170 MHz dB - 0.9 1.8 Notes : (1) Typical values are nominal performances at room temperature. (2) External matching network is required. (3) The amplitude variation is defined as the maximum level – minimum level over the given bandwidth. Matching Network
SAW Bandpass Filter – WCDMA Rx – RF Specification (Rev 1) October 25th, 2005 Nominal Frequency Response (Measurements ) Frequency Response Frequency Response
SAW Bandpass Filter – WCDMA Rx – RF Specification (Rev 1) October 25th, 2005 Maximum Ratings Operating Temperature Range °C [-25°C ; +85°C] Storage Temperature Range °C [-40°C ; +85°C] Marking LINE 1 LINE 2 Line 1: “P C” with P for the code product identification and C for the partner identifier Line 2: “Y W” with Y for the last digit of the year and W for the week code (A to Z for the week 1 to 26 and a to z for the week 27 to 52. Packaging 1. Temex label 2. ESD Prevention label 3. Pb free label (if applicable) Scanning Orientation