TMXU392 TEMEX

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

SAW Passband Filter - Remote Control - RF Specification (Rev-2)

SAW Passband Filter – Remote Control - RF Specification (Rev-2) March 03rd, 2005 TEME X r eserves th e right to modify her ein spe cifications an d in form ations at any time when ne cessa ry to pr ovide optimum per form ance an d cost. Electrical Parameters Unit Minimum Typical (1) Maximum Source Impedance (single ended) Ω - 50(2) - Load Impedance (single ended) Ω - 50(2) - Center Frequency fo MHz - 915 - Absolute Attenuation

100 MHz to 800 MHz dB 50 60 -

800 MHz to 845 MHz dB 45 50 -

845 MHz to 880 MHz dB 35 40 -

947 MHz to 992 MHz dB 15 20 -

992 MHz to 1020 MHz dB 35 40 -

1020 MHz to 1200 MHz dB 45 50 -

Maximum Insertion Loss in 902 MHz-928 MHz dB - 2.5 3.3 Ripple in 902 MHz-928 MHz dB - 0.5 1.5 Package type & size Length x Width mm² - 3.0 x 3.0 - Height mm - 1.3 1.5 Pin Out Input 2 Output 5 Case Ground 1,3,4,6 To Be Grounded 1,3,4,6 Notes : (1) Typical values are nominal performances at room temperature (2) No external matching circuit is required 50 Ω / 50 Ω CONFIGURATION Input 50 Ω Single Output 50 Ω Single GND Maximum Ratings Rating Unit Value Operating Temperature Range TA 0 to +70 °C Storage Temperature Range Tstg -45 to +85 °C Input Power 15 dBm

SAW Passband Filter – Remote Control - RF Specification (Rev-2) March 03rd, 2005 TEME X r eserves th e right to modify her ein spe cifications an d in form ations at any time when ne cessa ry to pr ovide optimum per form ance an d cost. TYPICAL S21 RESPONSE PACKAGE DRAWING