TMXAT14 TEMEX
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
SAW Bandpass Filter – Remote Control - RF Preliminary Specification (Rev 1)
SAW Bandpass Filter – Remote Control - RF Preliminary Specification (Rev.1)- RF February 09th, 2006 TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum perform ance and cost.
Features
RF SAW Filter for Home appliance 915 MHz Center Frequency 26 MHz useable Passband 50 Ohms Single Configuration Ceramic package for Surface Mounted Technology Package Drawing & Pin out The product is in conformance with the European RoHs Regulation 2002/95. Pin Configuration Input B Output E Ground A, C, D, F
SAW Bandpass Filter – Remote Control - RF Preliminary Specification (Rev.1)- RF February 09th, 2006 TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum perform ance and cost. Technical Characteristics Reference Temperature : +25°C Electrical Parameters Unit Minimum Typical (1) Maximum Source Impedance (single) Ohms - 50 - Load Impedance (single) Ohms - 50 - Center Frequency fc MHz - 915 - Bandwidth MHz 26 - - Absolute Attenuation DC to 800 MHz dB 50 60 -
800 MHz to 845 MHz dB 50 55 -
845 MHz to 879 MHz dB 45 50
950 MHz to 990 MHz dB 25 30
990 MHz to 1200 MHz dB 50 60
1200 MHz to 2000 MHz dB 30 38 -
Insertion Loss within 902 MHz ~ 928 MHz dB - 2.5 3.2 Ripple within 902 MHz ~ 928 MHz dB - 0.7 1.6 VSWR within 902 MHz ~ 928 MHz - - 1.45 2.0 Matching Network
SAW Bandpass Filter – Remote Control - RF Preliminary Specification (Rev.1)- RF February 09th, 2006 TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum perform ance and cost. Nominal Frequency Response Frequency Response Not Frequency Response
SAW Bandpass Filter – Remote Control - RF Preliminary Specification (Rev.1)- RF February 09th, 2006 TEMEX reserves the right to modify herein specifications and informations at any time when necessary to provide optimum perform ance and cost. Maximum Ratings Storage Temperature Range °C [-40°C ; +85°C] Operable temperature Range °C [-30°C ; +80°C] DC Voltage V 5 Input power dBm 20 Marking LINE 1 LINE 2 Line 1: "NNNN" is the reference to Temex Part number with only the last 4 digits Line 2: RYWWZZ is the date code as: R: Partner identifier. Y: last digit of the year. WW: number of week in the year ZZ: Lot number in the week (from AA to ZZ). Packaging Scanning Orientation 1 – Temex Label 2 – ESD Prevention Label 3 – Pb Free Label