TCK127 TRACOPOWER
Document overview
- PDF pages: 1
Technical content
Page 1
Common Mode Choke
TCK-127
| Order Code | TCK-127 |
| Inductance (each winding) | 137 µH ±25% (at 10 kHz / 50 mV) |
| Impedance (DCR) | 24 mΩ max. |
| Rated Current | 1.92 A max. |
| Rated Voltage | 500 VDC max. (between windings) |
| Operating Temperature | -40°C to +105°C |
| RoHS Exemptions | No Exemptions |
Impedance Curve

Outline Dimensions

All specifications valid at +25°C, unless otherwise stated.
© Copyright 2022 Traco Electronic AG
| Dimensions [mm] | |
| A | 7.5 max. |
| B | 8.5 max. |
| C | 10.5 max. |
| D | 3.5 ±1.0 |
| E | 5.08 ±0.5 |
| F | 2.54 ±0.3 |
| G | ø 0.6 ±0.1 |
Specifications can be changed without notice.
Rev. November 30, 2022
www.tracopower.com