TCK017 TRACOPOWER

Document overview

  • PDF pages: 1

Technical content

Page 1

Common Mode Choke

TCK-017

PDF page 1 diagram
Order Code TCK-017
Inductance (each winding) 497 µH ±25% (at 100 kHz / 20 mV)
Impedance (DCR) 100 mΩ max.
Rated Current 1.7 A max.
Rated Voltage 500 VDC max. (between windings)
Operating Temperature -40°C to +105°C
RoHS Exemptions No Exemptions

Impedance Curve

PDF page 1 diagram

Outline Dimensions

PDF page 1 diagram

All specifications valid at +25°C, unless otherwise stated.

© Copyright 2022 Traco Electronic AG

Dimensions [mm]
A 11.5 max.
B 11.5 max.
C 8.8 max.
D 2.5 min.
E 7.62 ±0.2
F 7.62 ±0.2
G ø 0.6 ±0.1

Specifications can be changed without notice.

Rev. November 30, 2022

www.tracopower.com