DATASHEET SEARCH SITE

Document overview

  • PDF pages: 4

Technical content

Page 1

®

Telaire®

T7000 Series

Handheld Indoor Air Quality (IAQ) Monitors

Applications

  • Identify areas with low or substandard ventilation.
  • Identify hidden energy savings in over ventilated spaces.
  • Determine if ventilation is a factor in air quality complaints.
  • Locate the presence of combustion fumes from vehicles and appliances.
  • Use as a reference to calibrate wall mounted CO2 sensors.

Features

  • Patented dual beam, Absorption Infrared™ gas sensor ensures long term stability and durability.• Record temperature, CO2, RH and graph recorded data with supplied software (Model 7001D).
  • Record temperature, CO2, RH and graph recorded data with supplied software (Model 7001D)
  • Large, easy-to-read display. Temperature displayed in °F or °C. CO2 displayed in ppm. Easily adjusted for altitude changes.
  • Fast, simple calibration using external port and display. Calibrate with ambient air or bottled gas.

Amphenol

Advanced Sensors

PDF page 1 diagram
  • Calibrate, set elevation, change °F or °C using on-board controls
  • Flip out stand for desktop monitoring.
  • Voltage output via RJ45 connector provides easy interface to most data loggers.
  • Plug in AC power adaptor.
  • Operates for up to 80 hours on four AA alkaline batteries (not included).
  • Calculates and displays real-time ventilation rates in CFM or Liters/minute per person based on differential CO2 levels outside and inside the building..

Page 2

Telaire T7001

Telaire T7000SK

Equipped with Telaire’s patented dual beam Absorption The Telaire 7T000SK combines the Telaire T7001 with a Infrared™ technology, the Telaire T7001 is an easy-

technical reference library (CD), graphing software and

to-use CO2/temperature monitor designed for use in

Ventulator™ energy analysis program. The Ventulator

residential or commercial applications. With the ability calculates potential energy savings and provides a to display CO2 readings and calculate air ventilation

detailed report to support your control strategy. The VG

rates in cfm/person, the monitor is an ideal tool

Graphing software is a “real-time” graphing software

for: identifying energy saving opportunities in over-

that records and graphs CO2 data directly to your

ventilated spaces, determining if air quality complaints computer. are due to insufficient ventilation, or locating the presence of combustion fumes generated from vehicles and appliances. It comes with a power adapter.

PDF page 2 diagram

Telaire T7001i

The T7001i monitor combines the standard Telaire T7001 CO2/temperature monitor with an international adapter kit..

PDF page 2 diagram

Telaire T7001D

The T7001D combines the Telaire T7001 and Hobo data logger to provide you with everything you need to record and graph CO2, temperature, and relative humidity.

PDF page 2 diagram

Page 3

T7000 Series Specifications

Method Dual beam, Absorption Infrared

Sample Method Diffusion or flow through (50 to 100 ml/min)

Display-LCD Independent CO2 and temperature readings. Calculates and displays ventilation rates.

General

Operating Conditions

  • 32°F to 122°F (0°C to 50°C)
  • 0 to 95% RH, non-condensing

Storage Temperatures -4°F to 140°F (-20°C tp 60°C)

Certification CE FCC Class 15 Part B

Warranty 18 months parts and labor

Performance—CO2 Channel

Measurement Range

  • 0 to 10,000 ppm display
  • 0 to 4000 ppm voltage output

Display Resolution ±1 ppm

Accuracy 0 – 2000 ppm: ±50 ppm or 5% of reading, whichever is greater 2000 – 10000 ppm: +/- 10% of the reading

Repeatability ±20 ppm or 2% of the reading whichever is greater

Temperature Dependence 0 – 2000 ppm: ±0.1% of reading per °C or ±2 ppm per °C, whichever is greater, referenced at 25°C. 2000 – 10000 ppm: ±0.2% of reading per °C referenced at 25°C

Pressure Dependence 0.13% of reading per mmHg (corrected via user input for elevation)

Response Time <60 seconds for 90% of step change

Warm-Up Time <60 seconds at 72°F (22°C)

Calibration Interval 12 months, offset adjustment using single gas at 0 to 1000 ppm CO2. Full factory calibration available.

Performance—Temperature Channel

Temperature Range

  • Voltage output: 32°F to 104°F (0°C to 40°C)
  • Display: 32°F to 122°F (0°C to 50°C)

Display Resolution 0.1°F (0.1°C)

Display Options °F, °C

Accuracy ±2°F (±1°C)

Response Time 20 to 30 minutes (case must equilibrate with environment)

Calibration Interval 12 months, offset adjustment using temperature standard at 50°F to 86°F (10°C to 30°C). Full factory calibration available.

Output—Analog

CO2 0 to 4 VDC, 1 mV/ppm (4000 ppm maximum)

Temperature 0 to 4 VDC linear, 32°F to 104°F (0°C to 40°C)

Output Impedance 100 ohms

Digital Output RS232 for use with Telaire CO2View graphing software

Wiring Connection One RJ45 to connector dual analog output plus digital output

Page 4

Power Supply

Battery Type Four AA batteries of any type (not included)

Battery Operation 80 hours (alkaline)

External 6 VDC from external AC/DC adapter (included)

Power Requirements 100 mA peak, 20 mA average from 6V

CFM/Person Ventilation Rate Measurement

The Telaire T7000 Series will calculate the outside air ventilation rate to a space based on the inside/outside CO2 differential readings. Outside readings can be established by measuring outside levels and holding the “enter” button on the sensor for five seconds. The outside reading can also be manually set using the on- board keypad and display (default 400 ppm).

Accurate interpretation of the ventilation rate indicator requires a measuring two to three hours

T7000 Series Accessories/ Ordering Information

T2070 Cable Voltage output cable, includes two pigtail leads for connecting to third party devices.

T2075NG Calibration Kit Comes with regulator, flowmeter and tubing. Gas is not included.

T2077 Hobo Data Logger Kit (included in T7001D) Comes with small size Hobo data logger, software and all necessary connection cables for recording and graphing measurements. The data logger includes internal RH and temperature sensors and can record their outputs along with T7001 CO2 measurements. It can be attached to the back of T7001.

T2080 CO2View Graphing software for logging CO2 concentrations directly to PC.

T62933 International Power Supply Kit

T62285 RJ45 to DB9 cable

after occupancy has stabilized in a space or at a peak Factory Calibration in daily CO2 concentrations. In other conditions the indicator may tend to overestimate ventilation rates.

The ventilation rate display assumes a people activity level in the measured space similar to an office type environment (1.2 MET). If higher levels of activity are present, the indicator may tend to underestimate ventilation levels.

Amphenol

Advanced Sensors

Call the factory for a RMA number.

www.telaire.com

www.amphenol-sensors.com

© 2014 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice. Other company names and product names used in this document are the registered trademarks or

trademarks of their respective owners.

AAS-920-315C-03/2014