www.vishay.com Vishay Revision: 13-May-2020 1 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Wet Tantalum SMD Capacitors, Tantalum Metal Case With Glass-to-Tantalum Hermetic Seal LINKS TO ADDITIONAL RESOURCES PERFORMANCE CHARACTERISTICS Operating Temperature: -55 °C to +85 °C (to +125 °C with voltage derating) DC Leakage Current (DCL Max.): at +25 °C and above: leakage current shall not exceed the values listed in the Standard Ratings table. Capacitance Range: 10 μF to 68 μF Capacitance Tolerance: ± 10 %, ± 20 % standard Voltage Rating: 50 V DC to 125 VDC
FEATURES
- Advanced SMD packaging with high volumetric efficiency, patents pending
- Enhanced performance, high reliability design
- SMD, standard tin / lead (Sn / Pb), 100 % tin (RoHS-compliant) available
- Mounting: surface-mount Increased thermal shock capability of 300 cycles
- Designed for the avionics and aerospace applications
- Material categorization: fo r definitions of compliance please see www.vishay.com/doc?99912 Note * This datasheet provides information about parts that are RoHS-compliant and / or parts that are non RoHS-compliant. For example, parts with lead (Pb) terminations are not RoHS-compliant. Please see the information / tables in this datasheet for details 333DDD3 D 3D Models Available Available Available
ORDERING INFORMATION
TYPE CASE CAPACITANCE CAPACITANCE DC VOLTAGE TERMINATION / RELIABILITY ESR CODE TOLERANCE RATING AT +85 °C PACKAGING GRADE See Ratings and Case Codes table This is expressed in picofarads. The first two digits are the significant figures. The third is the number of zeros to follow. K = ± 10 % M = ± 20 % This is expressed in volts. To complete the three-digit block, zeros precede the voltage rating. A decimal point is indicated by an “R” (6R3 = 6.3 V). Sn / Pb solder E = 7" (178 mm) reel L = 7" (178 mm), 1/2 reel R = 7" (178 mm), partial reel 100 % tin C = 7" (178 mm), reel H = 7" (178 mm), 1/2 reel U = 7" (178 mm), partial reel S = 48 h burn-in Z = non- established reliability S = standard DIMENSIONS in inches [millimeters] CASE CODE L (MAX.) L1 W H P T W WEIGHT g (AVERAGE) C 0.354 [9.0] 0.303 ± 0.008 [7.7 ± 0.2] 0.279 ± 0.008 [7.1 ± 0.2] 0.291 ± 0.008 [7.4 ± 0.2] 0.098 ± 0.008 [2.5 ± 0.2] 0.197 ± 0.008 [5.0 ± 0.2] 2.40 L L1 P P H TW TW W
www.vishay.com Vishay Revision: 13-May-2020 2 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 MARKING VOLTAGE CODE VC O D E 50 T 75 S 100 R 125 B STANDARD RATINGS CAPACITANCE AT +25 °C 120 Hz (μF) CASE CODE PART NUMBER MAX. ESR AT +25 °C 120 Hz () MAX. IMP. AT -55 °C 120 Hz () MAX. DCL (μA) AT MAX. CAPACITANCE CHANGE (%) AC RIPPLE +85 °C 40 kHz (mARMS) +25 °C +85 °C AND +125 °C
50 VDC AT +85 °C; 30 VDC AT +125 °C
68 C T22C686(1)050(2)(3)(4) 1.50 35 1 5 -25 8 15 1650
75 VDC AT +85 °C; 50 VDC AT +125 °C
33 C T22C336(1)075(2)(3)(4) 2.50 66 1 5 -25 5 9 1310
100 VDC AT +85 °C; 65 VDC AT +125 °C
15 C T22C156(1)100(2)(3)(4) 3.50 125 1 5 -18 3 10 1030
125 VDC AT +85 °C; 85 VDC AT +125 °C
10 C T22C106(1)125(2)(3)(4) 5.50 175 1 5 -15 3 10 832 Note
- Part number definitions: (1) Capacitance tolerance: K, M (2) Termination and packaging: C, H, E, L, R, U (3) Reliability level: Z, S (4) ESR: S POWER DISSIPATION CASE CODE MAXIMUM PERMISSIBLE POWER DISSIPATION AT +25 °C (W) IN FREE AIR C0 . 9 STANDARD PACKAGING QUANTITY CASE CODE UNITS PER REEL 7" FULL REEL 7" HALF REEL 7" PARTIAL REEL C 100 50 25 686T YYXX Polarity mark Voltage Week Capacitance Year Trademark
www.vishay.com Vishay Revision: 13-May-2020 3 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Notes
- Metric dimensions will govern . Dimensions in inches are rounded and for reference only. (1) A0, B0, K0, are determined by the maximum dimensions to the ends of the terminals extending from the component body and / or the body dimensions of the component. The clearance between the ends of the terminals or body of the co mponent to the sides and depth of the rotation of the component within the cavity of not more than 20°. (2) Tape with components shall pass around radius “R” without damage . The minimum trailer length may require additional length to provide “R” minimum for 12 mm embossed tape for reels with hub diameters approaching N minimum. (3) This dimension is the flat area from the edge of the sprocket hole to either outward deformation of the carrier tape between the embossed cavities or to the edge of the cavity whichever is less. (4) This dimension is the flat area from the edge of the carrier tape opposite the sprocket holes to either the outward deformation of the carrier tape between the embossed cavity or to the edge of the cavity whichever is less. (5) The embossed hole location shall be measured from the sprocket hole controlling the location of the embossment . Dimensions of embossment location shall be applied independent of each other. (6) B1 dimension is a reference dimension tape feeder clearance only. TAPE AND REEL PACKAGING in inches [millimeters] CARRIER TAPE DIMENSIONS in inches [millimeters] TAPE WIDTH W P 2 FE 1 E2 MIN. 16 mm 0.630 + 0.012 / - 0.004 0.079 ± 0.004 [2.0 ± 0.1] 0.295 ± 0.004 [7.5 ± 0.1] 0.069 ± 0.004 [1.75 ± 0.1] 0.561 [14.25] 0.004 [0.10] max. K (max.) B1 (max.) (6) 0.024 [0.600] max. 10 pitches cumulative tolerance on tape ± 0.008 [0.200] Embossment 0.069 ± 0.004 [1.75 ± 0.10] D 1 (min.) for components Maximum USER DIRECTION OF FEED Center lines of cavity A F W 0.030 [0.75] min. (3) 0.030 [0.75] min. (4) 0.079 ± 0.002 [2.0 ± 0.05] 0.157 ± 0.004 [4.0 ± 0.10] [1.5 + 0.10 - 0.0] B Maximum component rotation (Side or front sectional view) 20° For tape feeder reference only including draft. Concentric around B Deformation between embossments Top cover tape Top cover tape cavity size (1) DIRECTION OF FEED Cathode (-) Anode (+) Bending radius (2) R minimum: 16 mm = 1.181" (30 mm)R min. 20° maximum component rotation Typical component cavity center line Typical component center lineA (Top view) 0.9843 [250.0] Tape 3.937 [100.0] 0.039 [1.0] max. 0.039 [1.0] max. Camber Allowable camber to be 0.039/3.937 [1/100] (Top view) Non-cumulative over 9.843 [250.0]
www.vishay.com Vishay Revision: 13-May-2020 4 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 CARRIER TAPE DIMENSIONS in inches [millimeters] TYPE CASE CODE TAPE WIDTH W (mm) P1 K0 MAX. B 1 MAX. T22 C 16 0.476 ± 0.004 [12.0 ± 0.1] 0.31 [7.9] 0.45 [11.3] RECOMMENDED REFLOW PROFILES Capacitors should withstand reflow profile as per J-STD-020 standard PROFILE FEATURE SnPb EUTECTIC ASSEMBLY LEAD (Pb)-FREE ASSEMBLY Preheat / soak Temperature min. (T s min.) 100 °C 150 °C Temperature max. (Ts max.) 150 °C 200 °C Time (ts) from (Ts min. to Ts max.) 60 s to 120 s 60 s to 120 s Ramp-up Ramp-up rate (T L to TP) 3 °C/s max. 3 °C/s max. Liquidus temperature (TL) 183 °C 217 °C Time (tL) maintained above TL 60 s to 150 s 60 s to 150 s Peak package body temperature (Tp) 220 245 Time (tp) within 5 °C of the specified classification temperature (TC) 20 s 30 s Time 25 °C to peak temperature 6 min max. 8 min max. Ramp-down Ramp-down rate (T P to TL) 6 °C/s max. 6 °C/s max. Time 25 °C to peak temperature 6 min max. 8 min max. PAD DIMENSIONS in inches [millimeters] CASE CODE A (MIN.) B (NOM.) C (NOM.) D (NOM.)
25 TEMPERATURE (°C)
TIME (s) ts tL Time 25 °C to peak TL TP TC - 5 °Ctp Ts max. Ts min. Preheat area Max. ramp-up rate = 3 °C/s Max. ramp-down rate = 6 °C/s D C A B
www.vishay.com Vishay Revision: 13-May-2020 5 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 TYPICAL PERFORMANCE CHARACTERISTICS OF T22 CAPACITORS ELECTRICAL PERFORMANCE CHARACTERISTICS ITEM PERFORMANCE CHARACTERISTICS Category temperature range - 55 °C to +85 °C (to +125 °C with voltage derating) Capacitance tolerance ± 20 %, ± 10 % at +25 °C, 120 Hz Capacitance change by temperature L imit per Standard Ratings table ESR Limit per Standard Ratings table, at +25 °C, 120 Hz Impedance Limit per Standard Ra tings table, at -55 °C, 120 Hz DCL (leakage current) Limit per Standard Ratings table AC ripple current Limit per Standard Ratings table, at +85 °C and 40 kHz Reverse voltage Reverse voltage shall be in accordance wi th MIL-PRF-39006, paragraphs 3.23 and 4.8.19, except DC potential will be maximum of 3 V Maximum operating voltage OPERATING TEMPERATURE +85 °C +125 °C RATED VOLTAGE DC) SURGE VOLTAGE (VDC) DERATED VOLTAGE (VDC) 50 57.5 30 75 86.2 50 100 115.0 65 125 144.0 85 Surge voltage The DC surge voltage is the maximum voltage to which the capacitor can be subjected under any conditions including transients and peak ripple at the highest line voltage. The DC surge voltage is 115 % of rated DC voltage PERFORMANCE CHARACTERISTICS ITEM CONDITION POST TEST PERFORMANCE Surge voltage In accordance with MIL-PRF-39006: 85 °C 1000 successive test cycles at the applicable DC surge voltage specified in series with a 1 k resistor at the rate of 30 s ON, 5.5 min OFF Capacitance change Leakage current Within ± 10 % of initial measured value Not to exceed specified value Life testing In accordance with MIL-PRF-39006: capacitors shall be capable of withstanding a 2000 h life test at a temperature +85 °C at rated voltage, or a 2000 h life test at a temperature +125 °C at derated voltage Capacitance change Leakage current at 85 °C / 125 °C Leakage current at 25 °C ESR +10 % / -20 % of initial measured value Not to exceed 125 % of initial specified value Not to exceed specified value Not to exceed 200 % of specified value AC ripple life In accordance with MIL-PRF-39006: 2000 h, +85 °C
www.vishay.com Vishay Revision: 13-May-2020 6 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ENVIRONMENTAL CHARACTERISTICS ITEM CONDITION POST TEST PERFORMANCE Stability at low and high temperatures As specified in MIL-PRF-39006 Th e capacitors shall meet the requirements of MIL-PRF-39006 Seal MIL-PRF-39006 Method 112 of MIL-STD-202, conditions A and C When the capacitors are tested as specified in MIL-PRF-39006, there shall be no evidence of leakage. Moisture resistance MIL-PRF-55365 Method 106 of MIL-STD-202, number of cycles: 10 continuous cycles except that steps 7a and 7b shall be omitted. DC leakage Capacitance change ESR Not exceed 125 % of the specified value Within ±10 % of the initial measured value Not exceed the specified value Barometric pressure (reduced) Method 105 of MIL-STD-202, condition E (150 000 feet) (45,720.1 m). There shall be no mechanical or visual damage to capacitors post-conditioning. Low temperature storage MIL-PRF-39006 Method 502 of MIL-STD-810, Storage temperature: - 62 °C + 0 °C, - 3 °C Exposure time: 72 h followed by a 1 h exposure at + 125 °C + 7 °C, - 0 °C within 24 h after low temperature storage. DC leakage Capacitance change ESR Not to exceed 125 % of the specified value Within ± 10 % of the initial measured value Not exceed the specified value Salt atmosphere (corrosion) MIL-PRF-39006 Method 101 of MIL-STD-202, condition B (48 h), applicable salt solution: 5 % There shall be no harmful corrosion. Marking shall remain legible. MECHANICAL PERFORMANCE CHARACTERISTICS ITEM CONDITION POST TEST PERFORMANCE Shear test AEC-Q200-006 Apply a pressure load of 5 N for 10 s ± 1 s horizontally to the center of capacitor side body. DC leakage Capacitance change ESR Not to exceed 125 % of the specified value Within ± 10 % of the initial measured value Not exceed the specified value There shall be no mechanical or visual damage to capacitors post-conditioning. Solderability MIL-STD-202, method 208, test B ANSI/J-STD-002: SnPb solder - test B Pb-free solder - test B1 All terminations shall exhibit a continuous solder coating free from defects for a minimum of 95 % of the critical area of any individual lead. Resistance to solvent MIL-STD-202, method 215 There sh all be no mechanical or visual damage to capacitors post-conditioning. Marking shall remain legible, no degradation of the can material. Insulation resistance Method 302 of MIL-STD-202, condition B (500 V DC ± 10 %) The insulation resistance shall be not less than 100 M. The capacitors shall meet the requirements of MIL-PRF-39006. Shock (specified pulse) MIL-STD-202, method 213,condition D (500 g) The capacitors shal l meet the requirements of MIL-PRF-39006. Vibration, high frequency MIL-STD-202, method 204, condition H (80 g peak) The capacitors shall meet the requirements of MIL-PRF-39006. Random vibration MIL-STD-202, method 214, condition II-G (overall RMS 27.78 G) The capacitors shall meet the requirements of MIL-PRF-39006. Thermal shock MIL-STD-202, method 107, condition A Thermal shock shall be in accordance with MIL-PRF-39006 when tested for 300 cycles. Resistance to soldering heat MIL-STD-202, method 210, condition J, except with only one heat cycle Capacitance change ESR Leakage current Within ± 10 % of initial Initial specified value or less Initial specified value or less There shall be no mechanical or visual damage to capacitors post-conditioning.
www.vishay.com Vishay Revision: 13-May-2020 7 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 PERFORMANCE CHARACTERISTICS 1. Operating Temperature: capacitors are designed to operate over a temperature range of -55 °C to +125 °C. 2. DC Working Voltage: the DC working voltage is the maximum operating voltage for continuous duty at the rated temperature. 3. Surge Voltage: the surge voltage rating is the maximum voltage to which the capaci tors should be subjected under any conditions. This includes transients and peak ripple at the highest line voltage.
3.1 The surge voltage of capa citors is 115 % of rated DC
working voltage.
3.2 Surge Voltage Test: capacitors shall withstand the
surge voltage applied through a 1000 ± 10 % resistor in series with the capacitor and voltage source at the rate of one-half minute on, five and one-half minutes off, for 1000 successive test cycles at +85 °C.
3.3 Following the surge voltage test, the capacitance at
+25 °C shall not have changed by more than ± 10 % and the equivalent series resistance and DC leakage current will not exceed the values shown in the Standard Ratings table for each capacitor. 4. Capacitance Tolerance: the capacitance of all capacitors shall be within the specified tolerance limits of the nominal rating.
4.1 Measurements shall be ma de by the bridge method at
or referred to a frequency of 120 Hz at a temperature of +25 °C. The maximum voltage applied to the capacitors during measurement shall be 1 V RMS. Measurement accuracy of the bridge shall be within ± 2 %. 5. Capacitance Change With Temperature: the capacitance change with temperature shall not exceed the values given in the Standard Ratings table for each capacitor. 6. Equivalent Series Resistance: measurements shall be made by the bridge method at, or referred to, a frequency of 120 Hz at a temperature of +25 °C. A maximum of 1 V RMS shall be applied during measurement.
6.1 The equivalent series resistance shall not exceed the
maximum value in ohms listed in the Standard Ratings table for each capacitor.
6.2 The dissipation factor may be calculated from the
equivalent series resistance and capacitance values as shown: where: DF = dissipation factor in % R = ESR in C = capacitance in μF f = frequency in Hz At 120 Hz, the above equation becomes: For example, percent dissipation factor of a 30 μF, 6 V capacitor, which has a maximum ESR of 4.0 at +25 °C and 120 Hz, would be calculated as shown: 7. Leakage Current: measurements shall be made at the applicable rated working voltage at +25 °C ± 5 °C through application of a steady source of power, such as a regulated power supply. A 1000 resistor to limit the charging current shall be connected in series with each capacitor under test. Rated working voltage shall be applied to capacitors for 5 minutes before making leakage current measurements. TYPICAL CURVES OF IMPEDANCE AS A FUNCTION OF FREQUENCY AT VARIOUS TEMPERATURES 0.1 1.0 100 100 1K 10K 100K 1M 10M “C” Case 50 V Capacitors +125 °C +25 °C -40 °C -55 °C -20 °C +85 °C Frequency (Hz) Impedance (Ω) UP TO +85 °C (V) AT +125 °C (V) 50 30 75 50 100 65 125 85 DF 2fRC DF R x C 13.26 DF 2 x 120 x 4 x 30
www.vishay.com Vishay Revision: 13-May-2020 8 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
7.1 The maximum leakage curre nt for any capacitor shall
not exceed the maximum value in μA listed in the Standard Ratings table for each capacitor. Note
- Leakage current varies with applied voltage. See graph next column for the appropriate adjustment factor 8. Low Temperature Impedance: the impedance of any capacitor at -55 °C at 120 Hz, shall not exceed the values given in the Standard Ratings table. 9. Life Test: capacitors are capabl e of withstanding a 2000 h life test at a temperature of +85 °C or +125 °C at the applicable rated DC working voltage.
9.1 Following the life test, th e capacitors shall be returned
to 25 °C ± 5 °C. The leakage current, measured at the +85 °C rated voltage, shall not be in excess of the original requirement; the capacitance value shall not exceed 150 % of the initial requirement; the capacitance value shall not change more than + 10 % / - 20 % from the initial measurement. 10. Ripple Life Test at +85 °C: capacitors shall be tested in accordance with military specification MIL-PRF-39006 except that: a) Operation conditions: this test shall be run at a frequency of 40 kHz ± 2 kHz sinusoidal and at the RMS ripple current levels specified in the Standard Ratings table. b) Applied DC voltage shall be reduced so that the peak AC voltage plus DC voltage shall not exceed the rated voltage of the capacitor in either the forward or reverse direction.
10.1 When tested as specified above, capacitors shall meet
the following requirements: a) The DC leakage current at +25 °C and at +85 °C shall not exceed the original requirements. b) The capacitance shall not change more than ± 15 % from the initial measured value. c) The dissipation factor shall not exceed the original requirements. d) Visual examination: There shall be no damage, obliteration of marking or leakage of electrolyte. GUIDE TO APPLICATION 1. AC Ripple Current: subjecting a capacitor to an AC voltage causes an AC current to flow through it. The amplitude of the current is dependent on the impedance of the capacitor at the frequency of the applied signal: where: I = ripple current V = applied AC voltage Z = impedance of capacitor (frequency dependent) This current causes heating in the capacitor because of I 2R losses (R is the equivalent series resistance at the applied frequency). This heating or power dissipation, is one of the limiting factors of the capacitor’s ripple current rating. These power dissipation ratings are based on a calculated +50 °C internal temperature rise in still air. The maximum allowable ripple currents given in the Standard Ratings table are based on these ratings and the maximum equivalent series resistance at that frequency. The relationship is written as follows: where: P = maximum power I = maximum ripple current R = equivalent series resistance Therefore: where: R is in P is in W I is in A RMS TYPICAL LEAKAGE CURRENT FACTOR RANGE 0 10 20 30 40 50 60 90 100 70 80 1.0 0.9 0.8 0.6 0.5 0.7 0.4 0.3 0.2 0.09 0.08 0.06 0.05 0.07 0.04 0.03 0.02 0.1 0.01 LEAKAGE CURRENT FACTOR PERCENT OF RATED VOLTAGE I V Z ---= PI 2R= I P R ----=
www.vishay.com Vishay Revision: 13-May-2020 9 Document Number: 40187 For technical questions, contact: tantalum@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 2. AC Ripple Voltage: in operation, the peak voltage across the capacitor (DC working voltage plus peak ripple voltage) must not exceed the rated working voltage of the capacitor. The DC component of the applied voltage should be sufficiently large to prevent polarity reversal in excess of 3 V at +85 °C or 2 V at 125 °C. There will be a point at the lower frequency and capacitance values when the peak AC voltage will be the limiting factor on the ripple current - not its heating effects. 3. Ripple Current Multipliers: the Standard Ratings table list the maximum permissibl e RMS ripple current at 40 kHz for each rating. These values are based on the maximum power dissipation allowed at that frequency. This ripple current, will cause heating, which adds to the ambient temperature. The higher ambient temperatures, voltage derati ng or current derating is required (see “Ripple Current Multipliers” table). Also shown are the multipliers fo r ripple currents at various frequencies, caused by the frequency dependence of the (ESR) equivalent series resistance. (see “Typical ESR as a Function of Frequency” chart) TYP. ESR AS A FUNCTION OF FREQUENCYEQUIVALENT SERIES RESISTANCE RATIO 0.2 0.6 0.8 0.4 1.4 1.2 1.0 FREQUENCY (Hz) 10 100 1K 40K 100K10K 1M RIPPLE CURRENT MULTIPLIERS VS. FREQUENCY, TEMPERATURE AND APPLIES PEAK VOLTAGE FREQUENCY OF APPLIED RIPPLE CURRENT
120 Hz 800 Hz 1 kHz 10 kHz 40 kHz 100 kHz
AIR TEMP. IN °C 55 85 105 125 55 85 105 125 55 85 105 125 55 85 105 125 55 85 105 125 55 85 105 125 % of 85 °C rated peak voltage
www.vishay.com Vishay Revision: 01-Jan-2019 1 Document Number: 91000 Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA AR E SUBJECT TO CHANGE WITH OUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employee s, and all persons acting on it s or their behalf (collectivel y, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product , (ii) any and all liability, including without limitation specia l, consequential or incidental damages, and (iii) any and all implied warranties, incl uding warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applicatio ns are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular applic ation. It is the customer’s responsibility to validate tha t a particular product with the prope rties described in the product sp ecification is suitable for use in a particular application. Parameters provided in datasheets and / or specifications may vary in different ap plications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s term s and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay product s not expressly indicated for use in such applications do so at their own risk. Please contact authorized Vishay personnel to obtain writ ten terms and conditions rega rding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is gr anted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. © 2019 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED