Features

 Very highly efficient GaAs-LED  High reliability  UL version available  Spectral match with silicon photodetectors /g3  SFH 415: Same package as SFH 300, SFH 203/g3

Applications

 IR remote control of hi-fi and TV-sets, video tape recorders, dimmers  Remote control for steady and varying intensity  Smoke detectors  Sensor technology  Discrete interrupters

Grenzwerte (TA = 25 /g113C)/g3 Maximum Ratings Bezeichnung/g3 Parameter Symbol/g3 Symbol Wert/g3 Value Einheit/g3 Unit Betriebs- und Lagertemperatur/g3 Operating and storage temperature range Top; Tstg – 40 /g125+ 100 /g113C Sperrspannung/g3 Reverse voltage VR 5V Durchlassstrom/g3 Forward current IF 100 mA Stoßstrom, tp /g32/g310 /g80s, D = 0/g3 Surge current IFSM 3A Verlustleistung/g3 Power dissipation Ptot 165 mW Wärmewiderstand/g3 Thermal resistance RthJA 450 K/W Kennwerte (TA = 25 /g113C)/g3 Characteristics Bezeichnung/g3 Parameter Symbol/g3 Symbol Wert/g3 Value Einheit/g3 Unit Wellenlänge der Strahlung/g3 Wavelength at peak emission/g3 IF = 100 mA, tp = 20 ms /g79peak 950 nm Spektrale Bandbreite bei 50% von Imax/g3 Spectral bandwidth at 50% of Imax IF = 100 mA /g39/g79 55 nm Abstrahlwinkel/g3 Half angle/g3 SFH 415 /g3 /g3 /g77 /g3 /g3 /g114/g317 /g3 /g3 Grad Aktive Chipfläche/g3 Active chip area A 0.09 mm 2 Abmessungen der aktiven Chipfläche/g3 Dimensions of the active chip area L /g117B/g3 L /g117W 0.3 /g1170.3 mm 2 Abstand Chipoberfläche bis Linsenscheitel/g3 Distance chip front to lens top /g3 H /g3 4.2 /g1254.8 /g3 mm

Schaltzeiten, Ie von 10% auf 90% und von 90% auf 10%, bei IF = 100 mA, RL = 50 /g58/g3 Switching times, /g44e from 10% to 90% and from 90% to 10%, IF = 100 mA, RL = 50 /g58 tr, tf 0.5 /g80s Kapazität /g3 Capacitance/g3 VR = 0 V, f = 1 MHz Co 25 pF Durchlassspannung/g3 Forward voltage/g3 IF = 100 mA, tp = 20 ms/g3 IF = 1 A, tp = 100 /g80s /g3 /g3 VF/g3 VF /g3 /g3 1.3 (/g100 1.5)/g3 2.3 (/g100 2.8) /g3 /g3 V/g3 V Sperrstrom/g3 Reverse current/g3 VR = 5 V IR 0.01 (/g100 1) /g80A Gesamtstrahlungsfluss/g3 Total radiant flux/g3 IF = 100 mA, tp = 20 ms /g41e 22 mW Temperaturkoeffizient von Ie bzw. /g41e,/g3 IF = 100 mA/g3 Temperature coefficient of Ie or /g41e,/g3 IF = 100 mA TCI – 0.5 %/K Temperaturkoeffizient von VF, IF = 100 mA/g3 Temperature coefficient of VF, IF = 100 mA TCV – 2 mV/K Temperaturkoeffizient von /g79, IF = 100 mA/g3 Temperature coefficient of /g79, IF = 100 mA TC/g79 + 0.3 nm/K Kennwerte (TA = 25 /g113C)/g3 Characteristics (cont’d) Bezeichnung/g3 Parameter Symbol/g3 Symbol Wert/g3 Value Einheit/g3 Unit

Gruppierung der Strahlstärke Ie in Achsrichtung/g3 gemessen bei einem Raumwinkel /g58 = 0.01 sr/g3 Grouping of Radiant Intensity Ie in Axial Direction/g3 at a solid angle of /g58 = 0.01 sr Bezeichnung/g3 Parameter Symbol Wert Value Einheit/g3 Unit SFH 415 SFH 415-T1) SFH 415-U Strahlstärke/g3 Radiant intensity/g3 IF = 100 mA,/g3 tp = 20 ms /g3 /g3 I e min Ie max /g3 /g3 25/g3 /g3 /g3 25/g3 /g3 /g3 40/g3 /g3 /g3 mW/sr/g3 mW/sr Strahlstärke/g3 Radiant intensity/g3 IF = 1 A,/g3 tp = 100 /g80s /g3 /g3 Ie typ. /g3 /g3 /g3 /g3 350 /g3 /g3 450 /g3 /g3 mW/sr 1) SFH 415-T kann nicht einzeln bestellt werden. / SFH 415-T can not be ordered separately.

Relative Spectral Emission/g3 Irel = f (/g79)/g3 Forward Current/g3 IF = f (VF), single pulse, tp = 20 /g80s Permissible Pulse Handling Capability IF = f (/g87), TA = 25 /g113C/g3 duty cycle D = parameter OHRD1938 λ relΙ 880 920 960 1000 nm 1060 100 OHR01554 FV -210 -110 010 110 01 2 3 4 5 6 V 8 AΙ F t OHR00860 p -510 10 2 Ι F 10 3 10 4 DC 0.2 0.5 0.1 0.005 0.01 0.02 0.05 t p T Ι F t p TD = mA -410 -310 -210 -110 010 110 210s D = Radiant Intensity /g3 /g3 Single pulse, tp = 20 /g80s Radiation Characteristics, /g3 /g44rel = f (/g77) /g3 /g3 /g44e /g44e 100 mA = f (IF) OHR01551 10 -3 Ι F -210 10 -1 10 0 10 1 10 2 Ι e 100 mA eΙ -210 -110 010 110A A OHR01552 40 30 20 10 20 40 60 80 100 1200.40.60.81.0 ϕ 0.2 0.4 0.6 0.8 1.0 100 Max. Permissible Forward Current/g3 IF = f (TA)/g3 OHR00883 FΙ 100 120 20 40 60 80 100 120 mA TA RthjA = 450 K/W

Maßzeichnung/g3 Package Outlines Maße in mm (inch) / Dimensions in mm (inch). Empfohlenes Lötpaddesign Wellenlöten (TTW) Recommended Solder Pad TTW Soldering/g3 Maße in mm (inch) / Dimensions in mm (inch). 7.8 (0.307) 7.5 (0.295) 9.0 (0.354) 8.2 (0.323) 29 (1.142) 27 (1.063) 1.8 (0.071) 1.2 (0.047) 4.8 (0.189) 4.2 (0.165) ø5.1 (0.201) ø4.8 (0.189) 0.8 (0.031) 0.4 (0.016) 0.6 (0.024) 0.4 (0.016) 2.54 (0.100) spacing 5.9 (0.232) 5.5 (0.217) 0.6 (0.024) 0.4 (0.016) Area not flat Chip position Cathode GEOY6645 4 (0.157) OHLPY985 4.8 (0.189)

Lötbedingungen /g3 Soldering Conditions /g3 Wellenlöten (TTW) (nach CECC 00802)/g3 TTW Soldering (acc. to CECC 00802)/g3 /g3 Published by /g3 OSRAM Opto Semiconductors GmbH Leibnizstrasse 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. The information describes the type of component and shall not be considered as assured characteristics./g3 Terms of delivery and rights to change design re served. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sor ted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS. 1 A critical component is a component usedin a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system. 2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered. OHLY0598 50 100 150 200 250 100 150 200 250 300 T t C s 235 C 10 s C... 260 1. Welle 1. wave 2. Welle 2. wave

5 K/s 2 K/sca 200 K/s

CC... 130100

2 K/s

Zwangskühlung forced cooling Normalkurve standard curve Grenzkurven limit curves