DATASHEET SEARCH SITE

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

----- 1.0 SPECIFICATION REFERENCE Line Parameter

Description

1.1 Model description RSX-11 1.2 RoHS compliant Yes 1.3 Reference number 1.4 Rakon part number ----- 2.0 FREQUENCY CHARACTERISTICS Line Parameter Test Condition Value Unit 2.1 Frequency 19.2 to 52 MHz 2.2 Calibration tolerance Frequency at 25°C ±2°C and specified load capacitance ±10 to 50 ppm 2.3 Reflow shift Two consecutive reflows as per attached profile after 4 hours recovery at 25°C ±1 max ppm 2.4 Frequency stability over temperature Referenced to frequency reading at 25°C and the specified load capacitance ±15 to 50 ppm 2.5 Temperature range Operating temperature -40 to 85 2.6 Frequency perturbations Peak-to-peak deviation from the frequency versus temperature curve fit 5th order. Minimum of 1 frequency reading every 3°C over operating temperature range 1 max ppm 2.7 Long term stability Frequency drift over 1 year at 25°C ±1 max ppm 2.8 g sensitivity Gamma vector of all three axes from 30 Hz to 1500 Hz at 10 RMS 2 max ppb/g ----- 3.0 ELECTRICAL Line Parameter Test Condition Value Unit 3.1 Load capacitance (CL) Frequency is calibrated at room temperature 5 to 32 pF 3.2 Shunt capacitance (C0) Operating specification 0.5 to 3 pF 3.3 Pull ability Load and frequency dependant 0.5 min ppm/pF 3.4 Drive level Operating specification 30 max µW 3.5 Equivalent series resistance (ESR) 85 max Ω 3.6 Insulation resistance (IR) 100V ±15V at 25°C 500 min MΩ Page 1

----- 4.0 ENVIRONMENTAL Line Parameter 4.1 Shock Half sine-wave acceleration of 3000g peak amplitude. Duration: 0.3ms, Velocity: 12.3ft/s [MIL-STD-202 M213] 4.2 Moisture resistance 1000 hours at 85°C, 85% Relative Humidity. Biased. [MIL-STD-202 M106G] 4.3 Temperature cycling 1000 temperature cycles, where each cycle consists of a 25 minute soak time at -45°C followed by a 25 minute soak time at 85°C, with a 60 second maximum transition time between temperatures. Air to air transition. [JESD22 METHOD JA-104C] 4.4 Vibration 5g for 20 minutes. 12 cycles in each of 3 orientations. Test from 10-2000 Hz [JESD22-B103- 4.5 Storage temperature -55 to 105°C ----- 5.0 ENVIRONMENTAL Line Parameter 5.1 Shock 2 cycle drop it onto concrete for six directions (x, y, z) and one corner. The height is 152 cm. Dummy is 120g weight. 5.2 Moisture Resistance Temperature: 40ºC ±2ºC; Humidity : 90 ~ 95%; Time : for 240 hours; According to IEC 1178- 1.4.8.15 5.3 Thermal Shock 100 temperature cycles, where each cycle consists of a 25 minute soak time at -40ºC followed by a 25 minute soak time at 85ºC, with a 60 second maximum transition time between 5.4 Vibration Frequency: 10 ~ 55 Hz; Amplitude: 1.5 mm; Period: 1 min; Test time: X,Y,Z each direction 2h; According to IEC 1178-1.4.8.7 5.5 Storage temperature -40 to 85ºC ----- 6.0 MANUFACTURING INFORMATION Line Parameter 6.1 Washing Able to withstand aqueous washing processes 6.2 Reflow Able to withstand forced convection reflow process. Refer to “RSX/RGX crystals Pb-free Reflow” drawing 6.3 Packaging description Tape and reel. Standard packing quantity is 4000 units per reel ----- 7.0 MARKING Line Parameter 7.1 Package 2.0 x 1.6 mm 7.2 Type Laser engraved 7.3 Line 1 7.4 Line 2 [o] = Pin 1, [F] = Factory code, [YMD] = Date code 7.5 * Frequency code Frequency marking is only represented by the first four significant digits. For example, on a RSX-11 at 16.368MHz, its frequency marking will be 16.36MHz Page 2

Drawing Name: RSX-11 Model Drawing Page 3

Drawing Name: RSX-11 Tape & Reel Page 4

Drawing Name: RSX/RGX Crystals Pb-free Reflow Page 5