RM8 TEC
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
04-2015, Rev. 0415 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. SCHRACK General Purpose Panel/Plug-in Relays Power Relay RM 8 n 2 pole 25 A, 2 form C (2 CO) contacts n DC or AC coil n Mechanical indicator n Push-to-test button n Chassis or DIN rail mount Typical applications Cleaning equipment, heating and cooling equipment. Approvals VDE Cert. No. 40003144, UL E214025, Technical data of approved types on request. Contact Data Contact arrangement 2 form C (CO) Rated voltage 400VAC Max. switching voltage 400VAC Rated current 25A Limiting making current, 20ms max. 60A Switching power 6000VA Contact material AgCdO, AgNi90/10 Min. recommended contact load 24VDC/100mA Frequency of operation, with/without load, DC coil 960/6000h-1 Operate/release time max., DC coil 15/10ms Bounce time max., form A/form B, DC coil 4/6ms Contact ratings Type Contact Load Cycles IEC 61810 RM8 C (CO) 25 A, 250 VAC, cosφ=1 35°C 10x103 RM82 C (CO) 25 A, 250 VAC, cosφ=1 DC-coil, 65°C 10x103 UL 508 RM80 A/B (NO/NC) 25 A, 240 VAC, 1 phase per pole, general purpose 40°C 6x103 RM8 A/B (NO/NC) 25 A, 415 VAC, resistive, 45°C 10x103 RM82 A/B (NO/NC) 16 A, 415 VAC, resistive, 70°C 30x103 RM82 A/B (NO/NC) 240 VAC, 1phase, 2HP , 50°C 6x103 Mechanical endurance 10x106 operations Coil Data Coil voltage range 6 to 220VDC 6 to 400VAC Operative range, IEC 61810 2 Coil insulation system according UL class 130 (B) Coil versions, DC coil Coil code Rated Coil Rated coil STD LED PD3) LED+ voltage resistance power bipolar PD3) VDC Ω±10% 1)2) W 006 L06 0A6 LA6 6 32 1.1 012 L12 0B2 LB2 12 110 1.3 024 L24 0C4 LC4 24 475 1.2 048 L48 0E8 LE8 48 2000 1.2 060 L60 0G0 LG0 60 2850 1.3 110 M10 1B0 MB0 110 100001) 1.2 221 N21 2C1 NC1 220 400002) 1.2 Operate voltage, DC coil 75% of rated coil voltage Release voltage, DC coil 10% of rated coil voltage 1) Coil resistance ±12%, 2) Coil resistance ±15%. 3) Protection diode PD; standard polarity: +A1 / -A2. All figures are given for coil without pre-energization, at ambient temperature +23°C. Z
04-2015, Rev. 0415 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. SCHRACK General Purpose Panel/Plug-in Relays Power Relay RM 8 (Continued) Insulation Data Initial dielectric strength between open contacts 1500Vrms between contact and coil 2500Vrms between adjacent contacts 4000Vrms Initial surge withstand voltage between contact and coil 5000V(1.2/50µs) between adjacent contacts 6000V(1.2/50µs) Clearance/creepage between contact and coil ≥4.0/14.9mm between adjacent contacts ≥15.3/15.3mm Material group of insulation parts IIIa Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature for mounting/handling -20 to +40°C in operation DC coil -40 to +65°C AC coil -40 to +40°C
16 A contact load -40 to +70°C
Category of environmental protection IEC 61810 RTI - dust protected Vibration resistance (functional) form A (NO)/form B (NC) 10/5g, 30 to 150Hz Terminal type quick-connect Cover retention, pull/push force 100/100N Weight 81g Packaging unit 10/25 pcs. Coil Data (continued) Coil versions, AC coil Coil code Rated Operate Release Coil Rated coil STD LED voltage voltage voltage resistance power 50/60Hz 50/60Hz 50/60Hz VAC VAC VAC Ω±10%1)2) VA 2) Coil resistance ±15%. All figures are given for coil without pre-energization, at ambient temperature +23°C. Terminal assignment Bottom view on pins Dimensions Cover with mounting brackets, 6.3 mm quick connect terminals Cover with DIN-snap-on attachement horizontal vertical
04-2015, Rev. 0415 www.te.com © 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions Catalog product data, ‘Definitions’ section, application notes and all specifications are subject to change. SCHRACK General Purpose Panel/Plug-in Relays Power Relay RM 8 (Continued) Product code Contacts Version Enclosure Coil Coil Part number RM805024 2 form C, Without Mounting brackets DC-coil 24VDC 2-1393844-7 RM805524 2 CO contacts test button quick c. 6.3 mm AC-coil 24VAC 2-1393147-9 RM805615 25 A 115VAC 3-1393147-1 RM805730 230VAC 3-1393147-3 RM808024 DIN-snap-on DC-coil 24VDC 2-1393844-9 RM808524 horizontal AC-coil 24VAC 3-1393147-7 RM808730 230VAC 5-1393149-7 RM809024 DIN-snap-on DC-coil 24VDC 5-1393149-8 RM809615 vertical AC-coil 115VAC 3-1393147-8 RM809730 230VAC 3-1393147-9 RM835024 With mounting brackets DC-coil 24VDC 4-1393147-1 RM835524 test button quick c. 6.3 mm AC-coil 24VAC 4-1393147-3 RM835615 115VAC 4-1393147-4 RM835730 230VAC 4-1393147-6 RM838024 DIN-snap-on DC-coil 24VDC 4-1393147-8 RM838524 horizontal AC-coil 24VAC 5-1393147-0 RM838730 230VAC 5-1393147-1 RM839024 DIN-snap-on DC-coil 24VDC 5-1393147-4 RM839524 vertical AC-coil 24VAC 5-1393147-5 RM839730 230VAC 5-1393147-6 Product code structure Typical product code RM 8 0 9 024 Type RM Power relay RM8 Contact configuration 8 2 form C contacts (2 CO), 25A Version
0 AgCdO, without test button 3 AgCdO, with test button
2 AgNi90/10, without test button 7 AgNi90/10, with test button
5 cover with mounting brackets, 6.3mm quick connect terminals 8 cover with DIN-snap-on attachment, horizontal, 6.3mm quick connect terminals 9 cover with DIN-snap-on attachment, vertical, 6.3mm quick connect terminals Coil Coil code: please refer to coil versions table