RK408MS1 TEMEX
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
HIGH RELIABILITY 10-8 STABILITY CLASS OCXO | SPACE SOLUTIONS Date: 29 May 2018 Issue: Shortform, 51001203.110, Issue A4 Specifications subject to change without notice Page 1 of 2 www.rakon.com Specific requests can be emailed to Rakon: hirel@rakon.com RK408 MS1 The RK408 MS1 platform is a Space OCXO generating an ultra-low noise signal at low and high frequencies. This frequency source is featured by a remarkable frequency stability vs. temperature range down to ±20 ppb under vacuum and a noise floor down to -165 dBc/Hz. The RK408 MS1 can be screened following the guidance of MIL-PRF-55310 (Class 1, type 4, level S) or to an optimised and shorter flow. This product platform is ideal for navigation, positioning and SAR systems. Environmental Conditions Parameter Condition / Remarks Min. Typ. Max. Unit Operating temperature (TOP) Option A Option B Option C -20 -40 Switch-on temperature TSO -40 85 °C Non-operating temperature TNOP -40 85 °C Random vibration MIL-STD-202 Method 214, conduction K (46.3 grms) Sine vibration MIL-STD-202 Method 204, Condition D (20G) Mechanical shock MIL-STD-202, Method 213, conduction F: Half sine with a peak acceleration of 1500g for duration of 0.5ms Radiation Total Ionizing Dose (TID) of 100 kRad, low dose rate (36 to 360 rad/h), No SEL up to LET=60 MeV/mg/cm² Electrical Interface Parameter Condition / Remarks Min. Typ. Max. Unit Power supply Option 2 (12 V) 11 12 13 V Load impedance 45 50 55 Ω Supply voltage (Vs) Option 2 (12 V) 6.75 7.25 7.75 V Control voltage (Vc) When Vc option is selected 0 Vref V Phase Noise Parameter Condition / Remarks @ 10 MHz @ 100 MHz @ 120 MHz Unit Phase noise (max.)
1 Hz offset -100 -70 -65 dBc
10 Hz offset -130 -100 -95 dBc
100 Hz offset -150 -130 -125 dBc
1 kHz offset -160 -152 -150 dBc 10 kHz offset -165 -162 -162 dBc 100 kHz offset -165 -165 -165 dBc Note: Products with better phase noise performance can be delivered if required Features Applications 40 x 50 x 20 mm Frequency: 10 to 125 MHz Short lead time for 10, 20, 40, 50, 80, 100 and 120 MHz frequencies FvT: ± 20 ppb under Vacuum Low phase noise Steady state consumption:
2 W under vacuum
3 W under atmospheric pressure
Supply voltage: +12 V Warm up consumption: 5 W max Ageing ±300 ppb max over 18 years at 10 MHz Output wave form: sine 50 Ω Output level: 10 to 12 dBm Component selected as per ECSS-Q-ST-70-08C and ECSS-Q- ST-70-38C Materials selected as per ECSS-Q-ST-70 SAR systems GNSS receivers Navigation Low noise synthesizers Frequency generator unit (FGU) Micro D + SMA
HIGH RELIABILITY 10-8 STABILITY CLASS OCXO | SPACE SOLUTIONS Date: 29 May 2018 Issue: Shortform, 51001203.110, Issue A4 Specifications subject to change without notice Page 2 of 2 www.rakon.com Specific requests can be emailed to Rakon: hirel@rakon.com Frequency Characteristics Parameter Condition / Remarks Min. Typ. Max. Unit Nominal frequency Standard frequencies: 10, 100, 120 MHz 10 – 120 MHz Steady state input current power Vacuum @ -20°C 3 W Warm up supply power Vacuum, End of Life (EOL) 5 W Initial frequency accuracy Frequency pulling option 1 Frequency pulling option 2 ±0.1 ppm Allan variance tau = 1s 5*10-12 1*10-11 Frequency warm up Time needed to reach the initial frequency accuracy (1h ref.) 10 mn Output waveform Sine Output level Beginning of Life (BOL); Option 2 10 12 dBm Harmonics level -30 dBc Non harmonics level -85 dBc Frequency adjustment (Positive slope, option 2) 10 MHz typ. 100 MHz typ. 120 MHz typ. ±0.4 ±1.1 ±1.3 ppm Parameter Condition / Remarks 10 MHz 100 MHz 120 MHz Unit Frequency stability vs. Temperature (FvT) TOP option A, max value TOP option B, max value TOP option C, max value ±10 ±20 ±30 ±20 ±40 ±60 ±20 ±40 ±60 ppb Supply voltage sensitivity Over operating temperature, max value. ±1 ±2 ±2 ppb Load sensitivity Over operating temperature, max value. ±25 ±50 ±50 ppb Pressure Over operating temperature, max value. ±100 ±200 ±200 ppb Ageing over 1 day Over operating temperature, max value. ±100 ±300 ±500 ppb Ageing over 18 years Over operating temperature, max value. ±300 ±1000 ±1200 ppb Ordering Part Example Product Family RK = Rakon, 4xx = OCXO 08 = 10-8 stability class Frequency Pulling 1 = Internal calibration 2 = Voltage controlled Frequency (Fnom) 10M000000 = 10 MHz (Fout) R K 40 8 M S 1 A 1 1 FM 1 0 M 0 0 0 0 0 0 Model Option EM = EM, EQM = EQM, FM = FM Supply Voltage 2 = 12 V Package Type MS1 = 40x50x20mm Micro D + SMA PS1 = 40x50x20mm Pin side + SMA Temperature Stability A = -5°C to 60°C, ±10 to 20 ppb B = -20°C to 70°C, ±20 to 40 ppb C = -40°C to 75°C, ±30 to 60 ppb