RENF22R2MMW SCHNEIDER

Document overview

  • PDF pages: 35

Technical content

Page 1

Harmony, NFC modular timing relay, 8 A, 2 CO,

Characteristics

0.1 s…999 h, multifunction, 24...240 V AC/DC

Product availability : Stock - Normally stocked in distribution facility

Price\* : 90.00 USD

PDF page 1 diagram

Main

Range of Product

Harmony Timer Relays

Product or Component Type

Multifunction relay

Device short name

RENF22

Supported OS

Android

Software Version

V4.4 and above Zelio NFC downloadable from Google Play store)

App for product

Complementary

Discrete output type

Relay

Nominal output current

8 A 2 C/O timed contact, cadmium free

Contacts type and composition

1 C/O timed and instantaneous contact, cadmium free

Time delay type

Power on-delay On-delay and off-delay Pulse delay Asymmetrical on-delay and off-delay Interval Off-delay Symmetrical flashing Safe-guard Star-delta Asymmetrical flashing Bistable

Time delay range

0.1 s...999 h

Product Compatibility

NFC enabled mobile device

[Us] rated supply voltage

24...240 V AC/DC

Release input voltage

<= 2.4 V

Voltage range

0.85...1.1 Un

\* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price. Aug 25, 2021

Page 2

Maximum RF power transmitted

0.0002 mW

NFC operating frequency

13.56 MHz

Supply frequency

50...60 Hz +/- 5 % Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end

Connections - terminals

Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end 5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1

Tightening torque

5.3…8.8 lbf.in (0.60…0.99 N.m) IEC 60947-1

Housing material

Self-extinguishing

Repeat accuracy

+/- 0.2 % 10 s...999 h +/- 0.5 % 100 ms...10 s

Temperature Drift

+/- 0.05 %/°C

Voltage drift

+/- 0.2 %/V

Setting accuracy of time delay

+/- 1 % 1...999 h 77 °F (25 °C) +/- 2 % 1 h 77 °F (25 °C) +/- 20 ms 100 ms...10 s 77 °F (25 °C)

Control signal pulse width

100 ms with load in parallel 60 ms no-load

Insulation resistance

100 MOhm 500 V DC IEC 60664-1

Recovery time

120 ms on de-energisation

Power consumption in VA

3 VA 240 V AC

Power consumption in W

1.5 W 240 V DC 0.6 W 24 V DC

Switching capacity in VA

2000 VA

Minimum switching current

10 mA 5 V

Maximum switching current

8 A

Maximum switching voltage

250 V 100000 cycles for resistive load, 8 A at 250 V, AC

Electrical durability Mechanical durability

10000000 cycles

Rated impulse withstand voltage

5 kV 1.2/50 µs IEC 60664-1

Power on delay

100 ms

Creepage distance

4 kV/3 IEC 60664-1

Overvoltage category

III IEC 60664-1 MTTFd = 227.5 years 100 % duty cycle continuous operating condition at 30 °C

Safety reliability data Mounting position

Any position 35 mm DIN rail conforming to EN/IEC 60715

Mounting support Status LED

Un, green LED steady)power ON R1, amber LED steady)relay energised R2, amber LED steady)relay energised Pairing, green LED steady)communication status Un, green LED fast blinking)diagnosis mode R1, amber LED blinking)timing in progress R2, amber LED blinking)timing in progress

Maximum communication distance

10 mm

Response Time

2 s

Maximum Width

0.89 in (22.5 mm)

Net Weight

0.20 lb(US) (0.0904 kg)

Environment

Immunity to microbreaks

10 ms 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply with basic insulation

Dielectric strength

basic insulation

Standards

EN 61000-6-1 EN 61000-6-2 EN 61000-6-4 EN 61812-1 EN 61000-6-3

Directives

2014/35/EU - low voltage directive

Page 3

2014/53/EU - radio equipment directive 2014/30/EU - electromagnetic compatibility

Product Certifications

CE CSA KC UL CCC EAC DNV-GL

Ambient Air Temperature for

-4…140 °F (-20…60 °C)

Operation Ambient Air Temperature for Storage

-40…158 °F (-40…70 °C)

IP degree of protection

Housing IP40 IEC 60529 IP40 front face: conforming to IEC 60529 Terminals IP20 IEC 60529

Pollution degree

3 IEC 60664-1 20 m/s² 10…150 Hz)IEC 60068-2-6

Vibration resistance

15 gn not operating 11 ms IEC 60068-2-27

Shock resistance

5 gn in operation 11 ms IEC 60068-2-27

Relative humidity

95 % 77…131 °F (25…55 °C) Electrostatic discharge immunity test 6 kV contact discharge)level 3 EN/IEC 61000-4-2

Electromagnetic compatibility

Electrostatic discharge immunity test 8 kV air discharge)level 3 EN/IEC 61000-4-2 Fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 Fast transients immunity test 2 kV direct contact)level 3 IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Radiated radio-frequency electromagnetic field immunity test 10 V 0.15...80 MHz)level 3 IEC 61000-4-6 Electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 Immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11

Immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11 Radiated emissionclass B EN 55022 Conducted emissionclass A EN 55022 Electromagnetic field immunity test 3 V/m 1.4 GHz...2 GHz)level 2 IEC 61000-4-3 Electromagnetic field immunity test 1 V/m 2...2.7 GHz)level 1 IEC 61000-4-3

Ordering and shipping details

22376 - RELAYS-MEASUREMENT(RM4)

Category Discount Schedule

CP2

GTIN

03606480936203

Nbr. of units in pkg.

1

Package weight(Lbs)

3.66 oz (103.635 g)

Returnability

Yes

Country of origin

ID

Packing Units

Unit Type of Package 1

PCE

Package 1 Height

0.94 in (2.4 cm)

Package 1 width

3.17 in (8.05 cm)

Package 1 Length

3.72 in (9.45 cm)

Offer Sustainability

Sustainable offer status

Green Premium product WARNING: This product can expose you to chemicals including: Nickel compounds, which is known

California proposition 65

to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

REACh Regulation

REACh Declaration Pro-active compliance (Product out of EU RoHS legal scope)

EU RoHS Directive

EU RoHS Declaration

Mercury free

Yes

Page 4

RoHS exemption information

Yes

China RoHS Regulation

China RoHS declaration

Environmental Disclosure

Product Environmental Profile

Circularity Profile

End of Life Information

Page 5

PDF page 5 diagram

Page 6

Connections and Schema

Internal Wiring Diagram

PDF page 6 diagram

Page 7

Connections and Schema

Wiring Diagram

PDF page 7 diagram

Page 8

Function A: Power On-Delay Relay

Description On energisation of power supply, the timing period T starts. After timing, the output(s) R close(s).The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 8 diagram

Page 9

Function At: Power On-Delay Relay with Pause / Summation Control Signal

Description

On energisation of power supply, the timing period T starts.Timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R close(s).The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 9 diagram

T = t1 + t2 +…

Page 10

Function Ac: On-Delay and Off-Delay Relay with Control Signal

Description

After energisation of power supply and energization of Y1 causes the timing period T to start. At the end of this timing period, the output(s) R close(s). When deenergization of Y1, the timing T starts. At the end of this timing period T,the output(s) R revert(s) to its/their initial position. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 10 diagram

Page 11

Function Ad : Pulse Delayed Relay with Control Signal

Description

After energisation of power supply, pulsing or maintaining of energization of Y1 starts the timing T. At the end of this timing period T, the output(s) R close(s). The output(s) R reverts to its initial position the next time Y1 is energized in pulsation or permanent energized manner. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 11 diagram

Page 12

Function Ah : Pulse Delayed Relay (Single Cycle) with Control Signal

Description

After energisation of power supply, pulsing or maintaining of energization of Y1 starts the timing T. A single flashing cycle then starts with 2 timing periods T of equal duration (start with output(s) R in initial position). Output(s) R closes at the end of the first timing period T and reverts to its initial position at the end of the second timing period T. Re-energizing of Y1, either in pulsation or permanent energized manner, will re-start the single flashing cycle again. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 12 diagram

Page 13

Function Ak: Asymmetrical On-Delay and Off-Delay Relay With Control Signal

Description

After energisation of power supply and energization of Y1, timing starts for a period Ta. At the end of this timing period Ta, the output(s) R closes. Deenergization of Y1 causes a second timing period Tr to start. At the end of this timing period Tr, the output(s) R reverts to its initial state. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 13 diagram

Page 14

Function B: Single Interval Relay with Control Signal

Description After energisation of power supply, pulsing or maintaining of energization of Y1 starts the timing T. The output(s) R close(s) for the duration of the timing period T then revert(s) to its/their initial state. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 14 diagram

Page 15

Function Bw : Double Interval Relay with Control Signal

Description After energisation of power supply, transition of Y1 (either from energization to deenergization or vice-versa) will cause the output(s) R close(s) for the duration of the timing period T then revert(s) to its/their initial state. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 15 diagram

Page 16

Function C: Off-Delay Relay with Control Signal

Description After energisation of power supply and energization of Y1 causes output(s) R close(s). When Y1 deenergizes, timing T starts.At the end of this timing period T,the output(s) R revert(s) to its/their initial position.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 16 diagram

Page 17

Function D: Symmetrical Flashing Relay (Starting Pulse-Off)

Description On energisation of power supply, output(s) R starts at its/their initial state for timing duration T then change(s) to output(s) R close(s) for the same timing duration T.This cycle is repeated indefinitely until power supply removal. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 17 diagram

Page 18

Function Di: Symmetrical Flashing Relay (Starting Pulse-On)

Description On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration T then revert(s) to its/their initial state for the same timing duration T.This cycle is repeated indefintely until power supply removal.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 18 diagram

Page 19

Function Dt: Symmetrical Flashing Relay (Starting Pulse-Off) With Pause / Summation Control Signal

Description

On energisation of power supply, output(s) R starts at its/their initial state for timing duration T and the timing can be interrupted / paused each time Y1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, then changes to output(s) R close(s).The output(s) R close state will remain for the same timing duration T and the timing can be interrupted / paused each time Y1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state.This cycle is repeated indefintely until power supply removal.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 19 diagram

T = t1 + t2 +… T = t'1 + t'2 +…

Page 20

Function Dit: Symmetrical Flashing Relay (Starting Pulse-On) With Pause / Summation Control Signal

Description

On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration T and the timing can be interrupted / paused each time Y1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, then revert(s) to its/their initial state.The output(s) R at initial state will remain for the same timing duration T and the timing can be interrupted / paused each time Y1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R change(s) to close state.This cycle is repeated indefinitely until power supply removal.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 20 diagram

T = t1 + t2 +… T = t'1 + t'2 +…

Page 21

Function H: Interval Relay

Description On energisation of power supply, output(s) R close(s) and timing period T starts.At the end of the timing period T, the output(s) R revert(s) to its/ their initial state.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 21 diagram

Page 22

Function Ht: Interval Relay With Pause / Summation Control Signal

Description

On energisation of power supply, output(s) R close(s) and timing period T starts.The timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state. The second output (R2) can be either timed (when set to "TIMED" or instantaneous (when set to "INST").

Function: 2 Output

PDF page 22 diagram

T = t1 + t2 +…

Page 23

Function L: Asymmetrical Flashing Relay (Starting Pulse-Off)

Description

On energisation of power supply, output(s) R starts at its/their initial state for timing duration Tr then change(s) to output(s) R close(s) for the another timing duration Ta. This cycle is repeated indefinitely until power supply removal. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 23 diagram

Page 24

Function Li: Asymmetrical Flashing Relay (Starting Pulse-On)

Description

On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration Ta then change(s) to its/their initial state for timing duration Tr. This cycle is repeated indefinitely until power supply removal. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 24 diagram

Page 25

Function Lt: Asymmetrical Flashing Relay (Starting Pulse-Off) With Pause / Summation Control Signal

Description

On energisation of power supply, output(s) R starts at its/their initial state for timing duration Tr and the timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value Tr, then changes to output(s) R close(s). The output(s) R close state will remain for the same timing duration Ta and the timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value Ta, the output(s) R revert(s) to its/their initial state. This cycle is repeated indefinitely until power supply removal. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 25 diagram

Tr = t1 + t2 +… Ta = t'1 + t'2 +…

Page 26

Function Lit: Asymmetrical Flashing Relay (Starting Pulse-On) With Pause / Summation Control Signal

Description

On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration Ta and the timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value Ta, the output(s) R revert(s) to its/their initial state. The output(s) R at initial state will remain for timing duration Tr the timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value Tr, then changes to output(s) R close(s) This cycle is repeated indefinitely until power supply removal. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 26 diagram

Ta = t1 + t2 +… Tr = t'1 + t'2 +…

Page 27

Function N : Safe-Guard Relay

Description

After energisation of power supply and on energization of Y1 cause the output(s) R close(s) and starts the timing T. If the duration interval between 2 consecutive energization of Y1 is greater than the pre-set value T, the output(s) R close(s) at the end of the timing period. If the duration interval between 2 consecutive energization of Y1 is less than the pre-set value T, the output(s) R remain(s) closed and timing restarted base on the last energization of Y1. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 27 diagram

Page 28

Function O : Delayed Safe-Guard Relay

Description

On energisation of power supply, the timing T starts. At the end of this timing period, the output(s) R close(s). On energization of Y1, the output(s) R revert(s) to its/their initial state and the timing T restarts. If the duration interval between 2 consecutive energization of Y1 is greater than the pre-set value T, the output(s) R close(s) at the end of the timing period. If the duration interval between 2 consecutive energization of Y1 is less than the pre-set value T, the output(s) R remain(s) at its/their initial state and timing restarted base on the last energization of Y1. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 28 diagram

Page 29

Function P : Pulse Delayed Relay with Fixed Pulse Length

Description

On energisation of power supply, the timing T starts. At the end of this period, the output(s) R close(s) for a fixed time P then revert(s) to its/their initial state. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 29 diagram

P = 500ms

Page 30

Function Pt : Pulse Delayed Relay With Fixed Pulse Length and Pause / Summation Control Signal

Description

On energisation of power supply, the timing T starts. The timing can be interrupted / paused each time Y1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R close(s) for a fixed time P then revert(s) to its/their initial state. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 30 diagram

T = t1 + t2 + … P = 500ms

Page 31

Function Qt: Star-Delta Relay (2 CO Outputs with Split Common)

Description

On energisation of power supply, the output R3 & R4 initializes at its initial state such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).At the end of the timing period T, the output R3 closes such that deenergizes STAR CONTACTOR and causes t transition time starts.At the end of the transition time, the output R4 closes such that energizes DELTA CONTACTOR. Diagnostic feature not available.

Function: 2 Output

PDF page 31 diagram

T = 50, 60... ms

Page 32

Function Qtt: Star-Delta Relay (2 CO Outputs With Split Common) with Pause / Summation Control Signal

Description

On energisation of power supply, the output R3 & R4 initializes at its initial state such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).During STAR connection time, the timing can be interrupted / paused each time Y1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output R3 closes such that deenergizes STAR CONTACTOR and causes t transition time starts.At the end of the transition time, the output R4 closes such that energizes DELTA CONTACTOR. Diagnostic feature not available.

Function: 2 Output

PDF page 32 diagram

T = t1 + t2 +... t = 50, 60 ... ms

Page 33

Function TL : Bistable Relay with Control Signal On

Description

After energisation of power supply and on energization of Y1 cause the output(s) R close(s). The subsequent on energization of Y1 cause the output(s) R revert(s) to its/their initial state. This cycle is repeated indefinitely until power supply removal. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 33 diagram

Page 34

Function Tt : Retriggerable Bistable Relay with Control Signal On

Description

After energisation of power supply and on energization of Y1 cause the output(s) R close(s) and starts the timing T. If the duration interval between 2 consecutive energization of Y1 is greater than the pre-set value T, the output(s) R will toggle from its/their present status the end of the timing period. If the duration interval between 2 consecutive energization of Y1 is less than the pre-set value T, the output(s) R toggle from its/their present status as soon as Y1 energizes without completing T duration. The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 34 diagram

Page 35

Function W: Interval Relay with Control Signal Off

Description

After energisation of power supply and on energization of Y1 following by denergization of Y1, the output(s) R close(s) and starts the timing T.At the end of the timing period, the output(s) R revert(s) to its/their initial state.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

Function: 2 Output

PDF page 35 diagram

Legend

Relay de-energised Relay energised Output open Output closed

U - Supply
R1/R2 - 2 timed outputs
Ta - Adjustable On-delay
Tr - Adjustable Off-delay
Y1 - Retrigger / Restart control
R2 inst. - The second output is instantaneous if the right position is selected
T - Timing period
R4 - Delta contact output
t - Delay to switch ON Delta contact output
R3 - Star-Delta contact output