R72G, R72R
Ordering Information
See Ordering Informationon the following pages. ISO Symbols R72G Relieving R72G Non Relieving R72R Relieving R72R Non Relieving EXCELON®72 Pressure Regulator 1/4", 3/8"Port Sizes l EXCELON design allows in-line or modular installation l Full flow gauge ports l Balanced valve design for optimum pressure control l Push to lock adjusting knob with tamper resistant accessory l R72R reverse flow option l Modular installations with EXCELON 72, 73, and 74 series can be made to suit particular applications Technical Data Fluid: Compressed air Maximum pressure: 20 bar (290 psig) Operating temperature*: -20° to +65°C (0° to +150°F) * Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F). Approximate flow at 10 bar (150 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a droop of 1 bar (15 psig) from set: 33 dm 3/s (70 scfm) Gauge ports: 1/8"PTF with PTF main ports 1/8"ISO Rc with ISO Rc main ports 1/8"ISO Rc with ISO G main ports Materials: Body: Zinc Bonnet: Acetal Valve: Brass Elastomers: Nitrile Bottom plug: Acetal Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document.
Typical Performance Characteristics R72G, R72R FLOW CHARACTERISTICS 0 1 02 0 3 04 0 5 0 d m 3/s AIR FLOW 0 20 40 60 80 100 120 scfm OUTLET PRESSURE bar g 100 0 psig PORT SIZE: 1/4" INLET PRESSURE: 10 bar g (150 psig) RANGE: 0,3 to 10 bar Ordering Information.Models listed include unidirectional flow, ISO G threads, knob adjustment, relieving diaphragm, 0,3 to 10 bar (5 to 150 psig) outlet pressure adjustment range* without gauge. † Typical flow with 10 bar (150 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (15 psig) droop from set. Port Size Model Flow dm3/s (scfm) Weight kg (lb) G1/4 R72G-2GK-RMN 33 (70) 0,36 (0.79) G3/8 R72G-3GK-RMN 33 (70) 0,36 (0.79) Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. R 7 2 -H H H - HH H H Port Size Substitute 1/4" 2 3/8" 3 Threads Substitute PTF A ISO Rc taper B ISO G parallel G Diaphragm Substitute Relieving R Non relieving N Gauge Substitute With G Without N * Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. ** Units with 17 bar (250 psig) outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th digit and S at the 12th position. Adjustment Substitute Knob K T-bar T Alternative Models Outlet Pressure Adjustment Range* Substitute 0,3 to 2 bar (5 to 30 psig) C 0,3 to 4 bar (5 to 60 psig) F 0,3 to 10 bar (5 to 150 psig) M Flow Type Substitute Standard G Reverse flow R
R72G, R72R Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. 63 (2.48) 48 (1.89) 35 (1.38) 48 (1.89) 35 (1.38) 73 (2.88)33 (1.31) 26 (1.01) 26 (1.01) Dimensions mm (inches) Panel mounting hole diameter: 40 mm (1.57") Panel thickness: 0 to 4 mm (0"to 0.16") Accessories Quikclamp and Tamper Resistant Wall Mounting Bracket Quikclamp Wall Bracket Neck Mounting Bracket Panel Nut Cover and Seal wire 4224-50 4214-52 74316-50 Plastic: 4248-89 4255-51 Includes plastic panel nut Seal Wire: 2117-01 Ø 40 mm Pressure Gauge R1/8 Connection 1/8 PTF Connection 4 bar (60 psig): 18-013-990 18-013-211 10 bar (150 psig): 18-013-989 18-013-212 25 bar (360 psig): 18-013-908
R72G, R72R Our policy is one of continuous research and development. We reserve the right to amend, without notice, the specifications given in this document. Bracket Kit Reference Item Part Number Wall bracket 4224-50 Neck mounting wall bracket 74316-50 Quikclamp and Quikclamp wall bracket 4214-52 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under ‘Technical Data’. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Water vapor will pass through these units and will condense into liquid if air temperature drops in the downstream system. Install an air dryer if water condensation could have a detrimental effect on the application. Service Kits Item Type Part Number Service kit Relieving 4381-500 Non relieving 4381-501 Service kit includes diaphragm assembly, valve assembly, valve spring and o-rings. 4 (0.16) 18.6 (0.73) 6 (0.24) 42 (1.65) 5 (0.20) 20 (0.80) 12 (0.47) 38(1.50) 60 (2.36) Port CL 51 (2.00) 39 (1.54) Port CL 49 (1.93) 30 (1.18) 7 (0.28) Port CL 34 (1.34) 4,4 (0.17) Port CL 38 (1.50) Bracket Mounting Wall Bracket Use 4 mm (5/32") screws to mount bracket to wall. Quikclamp and Quikclamp Wall Bracket Use 5 mm (3/16") screws to mount bracket to wall. Neck Mounting for B72, R72, V72, includes plastic panel nut Use 4 mm (5/32") screws to mount bracket to wall. Port CL 59 (2.32) 74 (2.91) 38 (1.50)14 (0.55)