R2868 HAMAMATSU
Document overview
- PDF pages: 2
Technical content
Page 1
FLAME SENSOR
UV TRON® R2868
Quick Detection of Flame from Distance,
Compact UV Sensor with High Sensitivity and Wide Directivity,
Suitable for Flame Detectors and Fire Alarms.
Hamamatsu R2868 is a UV TRON ultraviolet detector that makes
use of the photoelectric effect of metal and the gas multiplication
effect. It has a narrow spectral sensitivity of 185 to 260 nm, being
completely insensitive to visible light. Unlike semiconductor
detectors, it does not require optical visible-cut filters, thus
making it easy to use.
In spite of its small size, the R2868 has wide angular sensitivity
(directivity) and can reliably and quickly detect weak ultraviolet
radiations emitted from flame due to use of the metal plate
cathode (eg. it can detect the flame of a cigarette lighter at a
distance of more than 5 m.).
The R2868 is well suited for use in flame detectors and fire
alarms, and also in detection of invisible discharge phenomena
such as corona discharge of high-voltage transmission lines.
APPLICATIONS
G Flame detectors for gas/oil lighters and matches G Fire alarms G Combustion monitors for burners G Inspection of ultraviolet leakage G Detection of discharge G Ultraviolet switching
GENERAL
| Parameters | Rating | Units |
|---|---|---|
| Spectral Response | 185 to 260 | nm |
| Window Material | UV glass | — |
| Weight | Approx. 1.5 | g |
| Dimensional Outline | See Fig. 3 | — |
MAXIMUM RATINGS
| Parameters | Rating | Units |
|---|---|---|
| Supply Voltage | 400 | Vdc |
| Peak Current 1) | 30 | mA |
| Average Discharge Current 2) | 1 | mA |
| Operating Temperature | -20 to +60 | °C |
CHARACTERISTICS (at 25°C)
| Parameters | Rating | Units |
|---|---|---|
| Discharge Starting Voltage (with UV radiation) | 280 | Vdc Max. |
| Recommended Operating Voltage | 325±25 | Vdc |
| Recommended Average Discharge Current | 100 | µA |
| Background 3) | 10 | cpm Max |
| Sensitivity 4) | 5000 | cpm Typ. |

NOTES:
1) This is the maximum momentary current that can be handled if its full width at half maximum is less than 10 µs. 2) If the tube is operated near this or higher, the service life is noticeably reduced. Use the tube within the recommended current values. 3) Measured under room illuminations (approximately 500 lux) and recommended operating conditions. Note that these values may increase if the following environmental factors are present. 1. Mercury lamps, sterilization lamps, or halogen lamps are located nearby. 2. Direct or reflected sunlight is incident on the tube. 3. Electrical sparks such as welding sparks are present. 4. Radiation sources are present.
- High electric field (including static field) generates across the tube. 4) These are representative values for a wavelength of 200 nm and a light input of 10 pW/cm2. In actual use, the sensitivity will vary with the wavelength of the ultraviolet radiation and the drive circuitry employed.
Figure 1: UV TRON’s Spectral Response and Various
Light Sources
TPT B0009EA 100 UV TRON s SPECTRAL RESPONSE
SUNLIGHT
50
GAS TUNGSTEN FLAME LIGHT
0
WAVELENGTH (nm) ULTRAVIOLET
VISIBLE
INFRARED
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subjected to change without notice. No patent rights are granted to any of the circuits described herein. © 1997 Hamamatsu Photonics K. K.
Page 2
FLAME SENSOR UV TRON® R2868
Figure 2: Angular Sensitivity (Directivity)

TPT B0010EA
Figure 4: Recommended Operating Circuit
Figure 3: Dimensional Outline (Unit: mm)
10MΩ
4.7 kΩ\*


\* Be sure to connect the 4.7 kΩ resistor within 2.5 cm from the anode lead end of UV TRON.
- UV TRON Driving Circuit C3704 series (Option)

Hamamatsu also provide the driving circuit C3704 series for R2868 operation. C3704 series include a high voltage power supply and a signal processing circuit in printed circuit board, which allows to operate R2868 easily as a flame sensor with the low input voltage (DC 6 to 30 V)
For the details, please refer to the datasheet of C3704 series.
TPT A0024EA

HAMAMATSU PHOTONICS K.K., Electron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205, U.S.A.: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 United Kingdom: Hamamatsu Photonics UK Limited: Lough Point, 2 Gladbeck Way, Windmill Hill, Enfield, Middlesex EN2 7JA, United Kingdom, Telephone: (44)181-367-3560, Fax: (44)181-367-6384
North Europe: Hamamatsu Photonics Norden AB: Färögatan 7, S-164-40 Kista, Sweden, Telephone: (46)8-703-29-50, Fax: (46)8-750-58-95
TPT 1008E01
Italy: Hamamatsu Photonics Italia S.R.L.: Via Della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)2-935 81 733, Fax: (39)2-935 81 741
MAR.1998 CR Created in Japan