SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR sameskydevices.com

FEATURES

  • temperature compensated
  • multiple pressure range options
  • absolute, gauge and sealed pressure options
  • stainless steel housing
  • o-ring seal
  • digital output SPECIFICATIONS parameter conditions/description min typ max units pressure range see Pressure Specifications for more details 0 6 MPa pressure reference gauge pressure, absolute pressure, sealed gauge pressue excitation 3.1 3.3 3.6 V current consumption standby current working current 0.1 mA mA output signal I2C (14 bit) I2C slave address 0x06D data ready time 2 ms response time 3 ms zero output at 10% - 90% 666 C hex span output at 10% - 90% 3,999 C hex insulation resistance at 250 Vdc 200 MΩ vibration 20 G (20~5,000 Hz) shock 100 G for 10 ms compensated temperature <100 kPa models all other models -20 operating temperature -40 105 °C storage temperature -40 125 °C life 1,000,000 cycles RoHS yes MECHANICAL parameter conditions/description min typ max units measured medium all 316L compatible liquids and gases housing/diaphragm stainless steel 316L dimensions Ø19 x 14 mm weight 19 25 g CUI Devices is now Same Sky! Learn More Additional Resources: Product Page | 3D Model

SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 2 of 7 sameskydevices.com BASIC PARAMETERS parameter conditions/description min typ max units accuracy1 ±0.5 %FS hysteresis ±0.05 ±0.1 %FS repeatability ±0.05 ±0.1 %FS zero temperature drift1 ±1.0 ±1.5 %FS span temperature drift1 ±1.0 ±1.5 %FS thermal hysteresis ±0.05 ±0.2 %FS long term stability ±0.25 %FS/year Note: 1. In the compensation temperature range, refer to 25°C. PRESSURE SPECIFICATIONS pressure range pressure reference2 overload pressure burst pressure 0~35 kPa G 300%FS 400%FS 0~100 kPa G, A 200%FS 300%FS 0~250 kPa G 200%FS 300%FS 0~600 kPa G 200%FS 300%FS 0~1.0 MPa G 200%FS 300%FS 0~1.6 MPa G, S 200%FS 300%FS 0~2.5 MPa G, S 200%FS 300%FS 0~4.0 MPa S 200%FS 300%FS 0~6.0 MPa S 200%FS 300%FS Note: 2. A=absolute pressure (vacuum is zero); G=gauge pressure (current atmospheric pressure as zero); S=sealed gauge pressure (calibrated atmospheric pressure is zero). PART NUMBER KEY Base Number PS02 - X XXXX P - 4W Pressure Reference: A = Absolute G = Gauge S = Sealed Gauge Pressure Range: 350K = 35 kPa 100K = 100 kPa 250K = 250 kPa 600K = 600 kPa 100M = 1 MPa 160M = 1.6 MPa 250M = 2.5 MPa 400M = 4 MPa 600M = 6 MPa Additional Resources: Product Page | 3D Model

SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 3 of 7 sameskydevices.com MECHANICAL DRAWING units: mm tolerance: ±0.1 mm unless otherwise noted WIRE CONNECTIONS Wire Color Function Red VDD Blue GND Yellow SCL White SDA ITEM DESCRIPTION MATERIAL PLATING/COLOR A housing SS 316L B diaphragm SS 316L C oil filling silicon oil D o-ring NBR black E wires silicon; OD: 1.4 mm; 0.15 mm² O-ring Tube only present on gauge pressure models INTERFACE DIAGRAM Additional Resources: Product Page | 3D Model

SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 4 of 7 sameskydevices.com I2C OPERATION S P A N from master to slave from slave to master START condition STOP condition acknowledge not acknowledge SP AASlaveAddr 0 Command write Convert Pressure Value Pressure (kPa) = Pmax/0.8*(x/223-0.1) Read Data PNASA ASlaveAddr 1 Measurement <23:16> read Measurement <15:8> Measurement <7:0> Command Request I2C slave address: Ox06D Pressure Command: 0x06 Temperature Command: 0x09 Convert Temperature Value For x<223: Temperature (⁰C) = x/216+25 For x≥223: Temperature (⁰C) = (x-224)/216+25 Steps to read data from PS02 sensor 1. Write the corresponding command to the sensor (0x06 for pressure, 0x09 for temperature). 2. Read three bytes from the sensor. 3. Combine these three bytes into a single 24-bit value. 4. Convert the 24-bit value to a standard pressure or temperature unit using the formulas below. Additional Resources: Product Page | 3D Model

SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 5 of 7 sameskydevices.com SDA SCL t t t t t t t ttHDSTA LOW HDDAT SUDAT HIGH SUSTA HDSTA SUSTO BUS Specification Symbol Min Typical Max Unit SCL clock frequency fSCL 100 -- 400 kHz Start condition hold time relative to SCL edge tHDSTA -- 0.6 -- µs Minimum SCL clock low width tLOW -- 1.3 -- µs Minimum SCL clock high width tHIGH -- 0.6 -- µs Start condition setup time relative to SCL edge tSUSTA -- 0.6 -- µs Data hold time on SDA relative to SCL edge tHDDAT -- 0.6 -- µs Data setup time on SDA relative to SCL edge tSUDAT -- 0.1 -- µs Stop condition setup time on SCL tSUSTO -- 0.6 -- µs Bus free time between stop condition and start condition tBUS -- 1.3 -- µs I2C TIMING CHARACTERISTICS PRESSURE TRANSFER FUNCTION 3FFF 3CCB 399A 0666 0333 0000 2000 Output (Hex Counts) Pmin Pmax Applied Pressure Output(%) Decimal(D) Hexadecimal(H) 0 0 0x0000 5 819 0x0333 10 1638 0x0666 50 8192 0x2000 90 14746 0x399A 95 15563 0x3CCB 100 16383 0x3FFF Additional Resources: Product Page | 3D Model

SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 6 of 7 sameskydevices.com USAGE CONSIDERATIONS 1. Do not touch the diaphragm with hard objects, which may cause damage to the diaphragm. 2. Strictly follow the wiring method, otherwise it may cause product damage or other potential faults. 3. Misuse of the product may cause danger or personal injury. 4. Pressure range can be selected higher or lower than actual conditions, but should be within ±30%FS. 5. Pressure reference consists of gauge pressure, absolute pressure, and sealed gauge pressure. a. Gauge pressure is based on the current atmospheric pressure. Generally, it refers to the measurement of pressure which is greater than the current atmospheric pressure. Negative pressure is a special case of gauge pressure. It refers that there is such working condition that the pressure of work site is lower than the current atmospheric pressure. b. Absolute pressure is based on vacuum. c. Sealed gauge pressure uses absolute pressure die for gauge pressure product based on the atmospheric pressure of production site. 6. Confirm the maximum overload of the applied system, which should be less than the overload protection limit of the sensor, otherwise it will affect the product life or even damage the product. 7. The material and process for manufacturing negative pressure sensors are different from those of positive pressure sensors. So, gauge pressure sensors cannot be used as substitue of negative pressure sensors. Additional Resources: Product Page | 3D Model

SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 7 of 7 Same Sky offers a one (1) year limited warranty. Complete warranty information is listed on our website. Same Sky reserves the right to make changes to the product at any time without notice. Information provided by Same Sky is believed to be accurate and reliable. However, no responsibility is assumed by Same Sky for its use, nor for any infringements of patents or other rights of third parties which may result from its use. Same Sky products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. sameskydevices.com rev. description date 1.0 initial release 12/14/2021 1.01 updated drawing 06/13/2022 1.02 logo, datasheet style update 08/05/2022 1.03 added I2C details 12/12/2023

1.04 CUI Devices rebranded to Same Sky 09/12/2024

The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

Additional Resources: Product Page | 3D Model