PMK225E ASTRODYNE

Document overview

  • PDF pages: 4

Technical content

Page 1

PDF page 1 diagram

225 Watt Enclosed Switching Power Supply with PFC

PDF page 1 diagram

Model Number

Output Voltage

Output Amps (max)

SINGLE OUTPUT

PMK225S-5E

5 VDC

40

PMK225S-12E

12 VDC

18.8

PMK225S-15E

15 VDC

15

PMK225S-24E

24 VDC

9.4

PMK225S-36E

36 VDC

6.25

PMK225S-48E

48 VDC

4.7

PMK225E series

225 Watts Output Power

Single Output

Universal 90-264VAC Input

5VDC to 48VDC Outputs

4242VDC Input to Output Isolation

Active Power Factor Correction

Ripple & Noise max. (Note 1 & 4) Efficiency

100mV pk-pk

75%

120mV pk-pk

79%

150mV pk-pk

80%

240mV pk-pk

80%

360mV pk-pk

81%

480mV pk-pk

81%

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

Page 2

PDF page 2 diagram

PMK225E series

225 Watt Enclosed Switching Power Supply with PFC

INPUT SPECIFICATIONS

Input Voltage Range

90-264 VAC (100-240VAC Nom.)

Frequency Range

47-63 Hz

Power Factor Correction

0.95, min. Nom I/P, FL

Inrush Current, typ:

30A @ 115VAC Cold Start, FL\* 60A @ 230VAC Cold Start, FL\*

Input Current (LL/HL)

3.8 Amps max. / 1.3 Amps max.

Leakage Current

<3.5mA, 240Vin, 50Hz

OUTPUT SPECIFICATIONS

Voltage and Current

See Selection Chart

Line Regulation (LL-HL)

±1%, max.

Load Regulation 10%-FL

±1%, max.

Preset Accuracy (Note 3)

±1%, typ (±2%, 5 Vout)

Ripple/Noise (Notes 1, & 4) See Selection Chart Over Voltage Protection

130% max. Auto Recovery \*

Over Current Protection

228% max. Auto Recovery \*

Short Circuit Protection

Auto Recover after fault condition is removed \*

Turn On Delay Time

<4S

Rise Time

<20mS, typ (Nom I/P, FL)

Hold Up Time

20mS, typ (Nom I/P, FL)

Over-Shoot/Under Shoot

<10% of Nominal Output

Remote Sense

Compensates for up to 0.5V drop

Remote Shutdown

Open Collector, Logic “1” = ON “0” = Off. No Termination necessary to maintain constant “On” operation

GENERAL SPECIFICATIONS

Isolation (Note 2)

I/P-O/P: 4242VDC I/P-Ground: 2121VDC O/P-Ground: 707VDC

Insulation Resistance

≥20MΩ

Efficiency (FL. Nom I/P)

See Selection Chart

Safety UL/cUL:

UL60950-1 2nd ed./ C22.2 60950-1 2nd ed.

UL-EU:

EN60950-1 2nd ed.

CE:

EN60601-1-2

CB:

IEC60950-1 2nd ed.

ENVIRONMENTAL SPECIFICATIONS

Oper. Temperature

-20 to +70°C (See Derate Curve)

Storage Temperature

-25 to +85°C \*

Relative Humidity

10% to +90%, non-cond.\* Storage: 5-95%

EMS Harmonics

Class D, 61000-3-2

Fluctuations

61000-3-3

ESD

61000-4-2

RS

61000-4-3

EFT

61000-4-4

Surge

61000-4-5

CS

61000-4-6

MS

61000-4-8

DIPS

61000-4-11

EMI

EN55022 Class B

MTBF Mil Std 217F, 25°C

79,000 Hrs, min.

Vibration

4G Peak, 50-500Hz, 3 Axes

Drop Test

70 CM

PHYSICAL SPECIFICATIONS

Size

3.86”W x 7.01”L x 1.5”H

Construction

Enclosed

Weight

1.54 lb, (700g)

NOTES

  1. All measurements should be made directly at the terminals of the power supply 2. Isolation for up to 1 minute duration. 3. Preset Accuracy measured at nominal load, 120VAC input. 4. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF ceramic bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.

\* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

Page 3

PDF page 3 diagram

PMK225E series

225 Watt Enclosed Switching Power Supply with PFC

MECHANICAL DIMENSIONS

PDF page 3 diagram

Input Connector: 3P / 8.25mm Pitch Terminal Block Output Connector: 6P / 8.25mm Pitch Terminal Block

Page 4

PDF page 4 diagram

Enclosed & Din rail:

225 Watt Enclosed Switching Power Supply with PFC

OUTPUT DERATING CURVE

EEELLLEEEC CCTTTRRRIIIC CCAAALLL SSSPPPEEEC CCIIIFFFIIIC CCAAATTTIIIO OON NN

PMK225E series

PDF page 4 diagram

Ambient (℃)

  1. 5V convection 2. 12、15、24、36、48V convection 3. Forced air cooling 18CFM
PDF page 4 diagram

Input voltage (VAC) 60Hz Ta=25℃

  1. 5V 2. 12、15、24、36、48V