PMK150E_16 ASTRODYNE

Document overview

  • PDF pages: 5

Technical content

Page 1

PDF page 1 diagram

150 Watt Enclosed Switching Power Supply with PFC

PDF page 1 diagram

Model Number

Output Voltage

Output Amps (max)

SINGLE OUTPUT

PMK150S-5E

5 VDC

30

PMK150S-12E

12 VDC

12.5

PMK150S-15E

15 VDC

10

PMK150S-24E

24 VDC

6.3

PMK150S-48E

48 VDC

3.2

DUAL OUTPUT

PMK150D-AE

5/12 VDC

15/7

PMK150D-BE

5/24 VDC

15/3.5

PMK150D-CE

12/24 VDC

7/3.5

PMK150D-DE

12/48 VDC

7/1.5

PMK150E series

150 Watts Output Power

Single and Dual Outputs

Universal 90-264VAC Input

5VDC to 48VDC Outputs

4242VDC Input to Output Isolation

Active Power Factor Correction

Line Regulation (max) Ripple & Noise

±1%

150mV pk-pk

±1%

150mV pk-pk

±1%

150mV pk-pk

±1%

150mV pk-pk

±1%

250mV pk-pk

±0.5/1%

50/100mV pk-pk

±0.5/2%

50/200mV pk-pk

±1/2%

100/200mV pk-pk

±1/4%

100/400mV pk-pk

Page 2

PDF page 2 diagram

150 Watt Enclosed Switching Power Supply with PFC

INPUT SPECIFICATIONS

Input Voltage Range

90-264 VAC (100-240VAC nom.)

Frequency Range

47-63 Hz

Power Factor Correction

0.96 min. at nom. Input

Inrush Current, typ at cold start: 30A @ 115VAC

60A @ 230VAC \*

Leakage Current

<3.5mA @ 264VAC, 50Hz

OUTPUT SPECIFICATIONS

Voltage and Current (Note 6) See Selection Chart Line Regulation (Note 8)

See Selection Chart

Load Regulation (20%-FL)

Singles: ± 1%, max.

Cross Regulation (note 7)

Duals: ±3/5%

Preset Accuracy (Note 9)

±1%, typ

Ripple/Noise (Notes 1, 3, 10) See Selection Chart Over Voltage Protection

130% max. of nom. input Auto Recover after fault condition is removed \*

Over Current Protection

150% max. of FL at nom. input

Short Circuit Protection

Auto Recover after fault condition is removed \*

Hold Up Time

20mS, typ (Nom I/P, FL)

GENERAL SPECIFICATIONS

Isolation (Note 4)

I/P-O/P: 4242VDC I/P-Ground: 2828VDC O/P-Ground:707VDC

Efficiency

75%, min. at nom. input

Safety UL/cUL:

UL60950-1 2nd ed./ C22.2 60950-1 2nd ed.

UL-EU:

EN60950-1 2nd ed.

CE:

EN60601-1-2

CB:

IEC60950-1 2nd ed.

All specifications are typical at nominal input, full load, and 25°C unless otherwise noted

\* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

PMK150E series

ENVIRONMENTAL SPECIFICATIONS

Oper. Temperature

-10 to +70°C (See Derate Curve)

Storage Temperature

-25 to +85°C \*

Relative Humidity

0% to +95%, non-cond \*

EMC

EN55011 Class B

MTBF

270,000 Hrs Mil Std 217, 25°C

PHYSICAL SPECIFICATIONS

Size

3.17” x 5.5” x 1.6”

Construction

Enclosed

Weight

1.3 lb, (590g)

NOTES

  1. All measurements should be made directly at the terminals of the power supply 2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load. 3. Ripple and noise dependent upon output voltage as specified per particular model. 4. Isolation for up to 1 minute duration. 5. Specified for free air convection cooling. 6. Minimum load is not required for proper operation. 7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load. 8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start. 9. Preset Accuracy measured at nominal load, 120VAC input.
  1. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.

Page 3

PDF page 3 diagram
PDF page 3 diagram
PDF page 3 diagram
PDF page 3 diagram
PDF page 3 diagram
PDF page 3 diagram
PDF page 3 diagram
PDF page 3 diagram

Page 4

PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram

Page 5

PDF page 5 diagram

PMK150E series

150 Watt Enclosed Switching Power Supply with PFC

OUTPUT DERATING CURVE - SINGLE OUTPUT

PDF page 5 diagram

OUTPUT DERATING CURVE - DUAL OUTPUT

PDF page 5 diagram
  1. Free air convection - Open Frame, U-Channel 3. Free air convection - Enclosed