PMK150 ASTRODYNE

Document overview

  • PDF pages: 4

Technical content

Page 1

Pmk150 series

150 Watt Open Frame Switching Power Supply with PFC

PDF page 1 diagram

Model Number

Output Voltage

Output Amps (max)

SINGLE OUTPUT

PMK150S-5

5 VDC

30

PMK150S-12

12 VDC

12.5

PMK150S-15

15 VDC

10

PMK150S-24

24 VDC

6.3

PMK150S-48

48 VDC

3.2

DUAL OUTPUT

PMK150D-A

5/12 VDC

15/7

PMK150D-B

5/24 VDC

15/3.5

PMK150D-C

12/24 VDC

7/3.5

PMK150D-D

12/48 VDC

7/1.5

150 Watts Output Power

Single and Dual Outputs

Universal 90-264VAC Input

5VDC to 48VDC Outputs

3000VAC Input to Output Isolation

Active Power Factor Correction

Line Regulation Ripple & Noise

±0.5%

100mV pk-pk

±0.5%

100mV pk-pk

±0.5%

100mV pk-pk

±0.5%

100mV pk-pk

±0.5%

100mV pk-pk

±0.5/1%

50/100mV pk-pk

±0.5/2%

50/200mV pk-pk

±1/2%

100/200mV pk-pk

±1/4%

100/400mV pk-pk

ASTRODYNE USA: 1-800-823-8082

Page 2

Pmk150 series

150 Watt Open Frame Switching Power Supply with PFC

INPUT SPECIFICATIONS

Input Voltage Range

90-264 VAC

Frequency Range

47-63 Hz

Power Factor Correction

0.96 to 0.98

Inrush Current, typ:

30A @ 115VAC 60A @ 230VAC \*

OUTPUT SPECIFICATIONS

Voltage and Current (Note 6) See Selection Chart Line Regulation (Note 8)

See Selection Chart

Load Regulation (10%-FL, Note 7) Singles:

± 0.5%, typ

Duals:

±3/5%, typ

Preset Accuracy (Note 9)

±1%, typ

DC Voltage Adjust (typ)

±6%, typ

Temperature Coefficient

±0.05%/°C

Ripple/Noise (Notes 1, 3, 10) See Selection Chart Over Voltage Protection

Latching, Auto Recover after fault condition is removed \*

Short Circuit Protection

Latching, Auto Recover after fault condition is removed \*

Hold Up Time

20mS, typ (Nom I/P, FL)

GENERAL SPECIFICATIONS

Isolation (Note 4)

I/P-O/P: 3000VAC I/P-Ground: 2000VAC O/P-Ground: 500 VAC

Efficiency

75%, min.

Switching Frequency

67Khz, (fixed, typical)

Safety

UL,TUV, CB, CE

All specifications are typical at nominal input, full load, and 25°C unless other­ wise noted

\* These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.

ENVIRONMENTAL SPECIFICATIONS

Oper. Temperature

-10 to +70°C (See Derate Curve)

Storage Temperature

-25 to +85°C \*

Relative Humidity

0% to +95%, non-cond \*

EMC

EN55011 Class B

MTBF

270,000 Hrs Mil Std 217, 25°C

PHYSICAL SPECIFICATIONS

Size

3” x 5.5” x 1.4”

Construction

Open Frame

Weight

0.5 lb, (226g)

Notes

  1. All measurements should be made directly at the terminals of the power supply 2. All specifications typical @ 25°C, unless otherwise noted, at nominal line and load. 3. Ripple and noise dependent upon output voltage as specified per particular model. 4. Isolation for up to 1 minute duration. 5. Specified for free air convection cooling. 6. Minimum load is not required for proper operation. 7. Load Regulation is measured by change ±40% of measured output load from 60% full load, with the other output set to 60% full load. 8. Line Regulation measured from 90-264VAC. 100VAC minimum required for full load start. 9. Preset Accuracy measured at nominal load, 120VAC input.
  1. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF bypass and 47uF electrolytic, pk-pk @ 20MHz bandwidth.
PDF page 2 diagram

ASTRODYNE USA: 1-800-823-8082

Page 3

Pmk150 series

150 Watt Open Frame Switching Power Supply with PFC

MECHANICAL DIMENSIONS

35.00 mm [1.378 in]

PDF page 3 diagram

5.70 mm [0.224 in]

134.00 mm [5.276 in]

139.70 mm [5.500 in]

Pin #

Outputs

1

GND

2

ACN

3

ACL

4

+ Output

5

+ Output

6

Common

7

Common Common N/C

ASTRODYNE USA: 1-800-823-8082

Page 4

Pmk150 series

150 Watt Open Frame Switching Power Supply with PFC

OUTPUT DERATING CURVE - Single Output

PDF page 4 diagram

OUTPUT DERATING CURVE - Dual Output

PDF page 4 diagram
  1. Free air convection - Open Frame, U-Channel 3. Free air convection - Enclosed

ASTRODYNE USA: 1-800-823-8082