Rated voltage 275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, CSA)
Capacitance range 0.01 – 10.0 µF Capacitance tolerance ± 20% standard, ± 10% option, ± 5% on request T emperature range –55 to +105°C Climatic category 55/105/56/B Approvals ENEC, UL, CSA Dissipation factor Maximum values at +23°C C ≤ 0.1 µF 0.1µF < C ≤ 1 µF C > 1 µF 100 kHz 0.6% –– T est voltage between The 100% screening factory test is carried terminals out at 2200 VDC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. Insulation resistance C ≤ 0.33 µF: ≥ 30 000 MΩ C > 0.33 µF: ≥ 10 000 s In DC applications Maximum voltage 630 VDC PHE840M EMI suppressor, class X2, metallized polypropylene 0.01 – 10.0 µF , 275/280 VAC, +105°C New, small dimensions including low profile capacitors Replaces PHE843 TYPICAL APPLICATIONS CONSTRUCTION TECHNICAL DATA For worldwide use as electromagnetic interference suppressor in all X2 and across-the-line applications. Metallized polypropylene film encapsulated with selfextinguishing epoxy resin in a box of material recognized to UL 94 V–0. p d std l max l b 7.5 ± 0.4 0.6 17 20 ±0.4 10.0 ± 0.4 0.6 17 30 ±0.4 15.0 ± 0.4 0.8 17 30 ±0.4 22.5 ± 0.4 0.8 6 30 ±0.4 27.5 ± 0.4 0.8 6 30 ±0.4 37.5 ± 0.5 1.0 6 30 ±0.7 Tolerance in lead length < 30 mm mm ≥ 30 mm mm L H B p l∅ d 0.5 b ENVIRONMENTAL TEST DATA Endurance IEC 60384–14 1.25 x U R VAC 50 Hz, once every hour increased to 1000 VAC for 0.1 s, 1000 h at upper rated temperature Vibration IEC 60068–2–6 3 directions at 2 hours each, No visible damage T est Fc 10 –55 Hz at 0.75 mm or 98 m/s
2 No open or short circuit
Bump IEC 60068–2–29 1000 bumps at No visible damage T est Eb 390 m/s2 No open or short circuit Change of temperature IEC 60068–2–14 Upper and lower rated No visible damage T est Na temperature 5 cycles Active flammability EN 132400 Passive flammability IEC 60384-14 (1993) Enclosure material of EN 132400 UL94V –0 flammability class UL1414 Humidity IEC 60068-2-3 +40 °C and 56 days T est Ca 90 – 95% R.H.
Capaci- Max dimensions reel Max Approvals tance in mm Bulk Tray t aped Weight f 0 dU/dt Article code µF B H L p pcs pcs pcs g MHz V/µs ENEC UL CSA LEAD SPACING 7.5 MM LEAD SPACING 10 MM LEAD SPACING 15 MM LEAD SPACING 22.5 MM * Only ± 20% tolerance
Capaci- Max dimensions reel Max Approvals tance in mm Bulk Tray taped Weight f 0 dU/dt Article code µF B H L p pcs pcs pcs g MHz V/µs LEAD SPACING 27.5 MM LEAD SPACING 37.5 MM * Only ± 20% tolerance ENEC UL CSA APPROVALS/REFERENCE DOCUMENTS Certification Body Specification Approval reference ENEC EN 132400 SE/0140-4A UL UL 1283 E100117 (UR = 280 VAC) UL 1414 E73869 (UR = 250 VAC) cUL recognition C 22.2 No. 8 E100117 (CSA) (U R = 280 VAC) C 22.2 No. 1 E73869 (UR = 250 VAC) ORDERING INFORMATION PACKING The box dimensions for bulk packaging are 245 x 145 x 80 mm. Quantity/package as per article table. Reels with taped capacitors are packed 10 in a box with dimension 370 x 370 x 560 mm. Quantity/reel according to article table. The standard quantity/reel is for 360 mm reel. If 500 mm reel is required, it must be specified when ordering and the quantity is 2 x the given quantity. MARKING
- RIFA
- RIFA article code
- Rated capacitance
- Capacitance tolerance code
- Rated voltage
- X2
- Approval marks
- Manufacturing date code
- IEC climatic category
- Passive flammability class The article code for the standard part is given in the article table. For other options, see page 21.