cui.com date 09/12/2018 page 1 of 8 SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR

FEATURES

  • 1 A of output current
  • efficiency up to 96%
  • industry standard SIP package
  • industrial operating temp -40~+85°C
  • designed to meet IEC/EN 62368-1
  • drop in equivalent LM78 regulator
  • no load input current of 0.2 mA
  • output short circuit protection on output MODEL input voltage1 output voltage output current output power ripple & noise2 efficiency3 typ (Vdc) range (Vdc) (Vdc) max (mA) max (W) max (mVp-p) typ (%) P78E03-1000 24 6~36 3.3 1000 3.3 75 90 P78E05-1000 24 8~36 8~27 1000 -500 2.5 P78E09-1000 24 13~36 9 1000 9 75 94 P78E12-1000 24 16~36 8~20 -12 1000 -300 3.6 P78E15-1000 24 20~36 8~18 -15 1000 -300 4.5 Notes: 1. For input voltages higher than 30 Vdc, a 22 µF / 50 V input capacitor is required. 2. Tested at nominal input, 20~100% load, 20 MHz bandwidth, with 10 µF electrolytic and 1 µF ceramic capacitor on the output. At loads below 20%, the max ripple and noise of the 3.3 & 5 Vdc outputs will be 100 mVp-p, and the other outputs will be 2% Vo. 3. Measured at min Vin, full load. 4. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY Base Number P78E XX-1000 Output Voltage Output Current For more information, please visit the product page.

cui.com date 09/12/2018 │ page 2 of 8CUI Inc │ SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR INPUT parameter conditions/description min typ max units operating input voltage5 for positive output applications for negative output applications Vdc Vdc filter capacitor filter input reverse polartiy protection no no-load input current positive outputs negative outputs 0.3 mA mA Note: 5. See Model section on page 1 for specific input voltage ranges. OUTPUT parameter conditions/description min typ max units maximum capacitive load6 for positive output applications for negative output applications 680 330 μF μF voltage accuracy at full load, input voltage range

3.3 Vdc output model

±1.5 line regulation at full load, input voltage range ±0.2 ±0.4 % load regulation at nominal input, 10~100% load positive output applications negative output applications ±0.4 ±0.4 ±0.6 ±0.8 switching frequency at nominal input voltage, full load 520 kHz transient recovery time at nominal input voltage, 25% load step change 1 ms transient response deviation at nominal input voltage ±60 ±200 mV temperature coefficient at full load ±0.03 %/°C Note: 6. The maximum capacitive load was tested at nominal input voltage, full load. PROTECTIONS parameter conditions/description min typ max units short circuit protection continuous, auto recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units safety approvals CE conducted emissions CISPR32/EN55032, class B (external circuit required, see Figure 4/5-b) radiated emissions CISPR32/EN55032, class B (external circuit required, see Figure 4/5-b) ESD IEC/EN61000-4-2, contact ± 4kV, class B radiated immunity IEC/EN61000-4-3, 10V/m, class A EFT/burst IEC/EN61000-4-4, ± 1kV, class B (external circuit required, see Figure 4/5-a) surge IEC/EN61000-4-5, line-line ± 1kV, class B (external circuit required, see Figure 4/5-a) conducted immunity IEC/EN61000-4-6, 3 Vr.m.s, class A MTBF as per MIL-HDBK-217F, 25°C 2,000,000 hours RoHS yes For more information, please visit the product page.

cui.com date 09/12/2018 │ page 3 of 8CUI Inc │ SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR 10 Sec. Max. Wave Soldering Time 4 Sec. Max. Peak Temp. 260°C Max. Time (sec.) Temperature (°C) 250 200 150 100 ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curves -40 85 °C storage temperature -55 125 °C storage humidity non-condensing 95 % SOLDERABILITY parameter conditions/description min typ max units wave soldering see wave soldering profile 260 °C MECHANICAL parameter conditions/description min typ max units case material black flame-retardant and heat-resistant plastic (UL94 V-0) weight 1.9 g MECHANICAL DRAWING units: mm [inch] tolerance: ±0.50[±0.020] pin diameter tolerance: ±0.10[±0.004] PIN CONNECTIONS PIN +OUTPUT -OUTPUT 1 +VIN +VIN

2 GND -VOUT

For more information, please visit the product page.

cui.com date 09/12/2018 │ page 4 of 8CUI Inc │ SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR DERATING CURVES Ambient T emper ature (°C) Load (% ) -40 100 04 0 120 120 71 80 85 Vin>26 V Vin≤26 V EFFICIENCY CURVES 6 10 14 18 22 24 28 32 36 90Efficiency (%) 85 Input Voltage (Vdc) 100 50 5 10 20 30 40 50 60 70 80 90 50Efficiency (%) Output Current (%) 100 P78E03-1000 Efficiency Curve Positive Output, Efficiency vs. Input Voltage (at full load) P78E03-1000 Efficiency Curve Positive Output, Efficiency vs. Load Current (at Vin nominal) 8 11 14 17 20 24 27 30 33 36 90Efficiency (%) Input Voltage (Vdc) P78E05-1000 Efficiency Curve Positive Output, Efficiency vs. Input Voltage (at full load) P78E05-1000 Efficiency Curve Positive Output, Efficiency vs. Load Current (at Vin nominal) 10 20 30 40 50 60 70 80 90 100

75 Efficiency (%)

Output Current (%) 100 Ambient T emper ature (°C) Load (% ) -40 100 04 08 5 120 12071 26<Vin≤30 V Vin≤26 V Ambient Temperature (°C) Load (%) -40 100 04 08 5 120 120 Temperature Derating Curves Positive 3.3, 5 Vdc Outputs (Natural Convection) Temperature Derating Curves Positive 9, 12, 15 Vdc Outputs (Natural Convection) Temperature Derating Curves Negative Outputs (Natural Convection) For more information, please visit the product page.

cui.com date 09/12/2018 │ page 5 of 8CUI Inc │ SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR 13 16 19 22 24 27 30 33 36 90Efficiency (%) 85 Input Voltage (Vdc) 100 5 10 20 30 40 50 60 70 80 90 100 50Efficiency (%) Output Current (%) 100 P78E09-1000 Efficiency Curve Positive Output, Efficiency vs. Input Voltage (at full load) P78E09-1000 Efficiency Curve Positive Output , Efficiency vs. Load Current (at Vin nominal) EFFICIENCY CURVES (CONTINUED) 16 19 22 24 27 30 33 36 90Efficiency (%) 85 Input Voltage (Vdc) 100 5 10 20 30 40 50 60 70 80 90 100 50Efficiency (%) Output Current (%) 100 P78E12-1000 Efficiency Curve Positive Output, Efficiency vs. Input Voltage (at full load) P78E12-1000 Efficiency Curve Positive Output, Efficiency vs. Load Current (at Vin nominal) 20 22 24 26 28 30 32 34 36 90Efficiency (%) 85 Input Voltage (Vdc) 100 5 10 20 30 40 50 60 70 80 90 100 50Efficiency (%) Output Current (%) 100 P78E15-1000 Efficiency Curve Positive Output, Efficiency vs. Input Voltage (at full load) P78E15-1000 Efficiency Curve Positive Output, Efficiency vs. Load Current (at Vin nominal) For more information, please visit the product page.

cui.com date 09/12/2018 │ page 7 of 8CUI Inc │ SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR PACKAGING units: mm Tube Size: 9.6 x 16.9 mm Tube QTY: 43 pcs per tube Carton Box Size: 285 x 125 x 610 mm Carton Box QTY: 5,504 pcs per carton box For more information, please visit the product page.

date 09/12/2018 │ page 8 of 8CUI Inc │ SERIES: P78E-1000 │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 09/12/2018 The revision history provided is for informational purposes only and is believed to be accurate.