DATASHEET SEARCH SITE

Document overview

  • PDF pages: 4

Technical content

Page 1

NPI-12 Series

Stainless Steel Media Isolated Sensors

Applications

  • Low-cost media isolation
  • 0.20 mV/V/psi sensitivity
  • Operating temperature 50°F to 104°F (10°C to 40°C)
  • 5 VDC excitation
  • Four-pin connector
  • Solid state reliability

Amphenol

Advanced Sensors

PDF page 1 diagram

Features

  • Level sensing
  • Automotive systems
  • Process control
  • Pneumatic controls
  • Hydraulic systems

Page 2

NPI-12 Series Specifications

Description

The NPI-12 Series of solid state, media isolated pressure

Parameter

sensors are designed to provide a cost effective

General

solution for applications that detect tube blockages

Pressure Range

and pump performance. The NPI-12 Series is intended

Maximum Overpressure Environmental

to mount adjacent to flexible tubing to sense tube

Temperature Range

expansion. Cleanliness is assured with the NPI-12 Series

Operating

stainless steel finish.

Storage Mechanical Weight

The NPI-12 Series incorporates state-of-the-art

Media Compatibility

IsoSensor technology, which gives the OEM user the

Diaphragm Dome Height

best in price and performance. They are designed to operate in hostile environments while providing

Electrical(2)

outstanding sensitivity, linearity and hysteresis. The

Excitation

piezoresistive sensor chip is housed in a fluid filled

Parameter

cavity and isolated from the measured media by

Value

Units Notes

15

psig

50

psig

50 to 104

°F (10°C to 40°C)

–40 to 158 (Dry) °F

(-40°C to 70°C)

0.01

lb (5 g)

316L stainless steel 0.000 to 0.008 in

1

(0.000 mm to 0.20 mm)

5.0

volts

Units Min. TypicaL Max. Notes

Performance Parameters (2)

a stainless steel diaphragm and body. As with all

Zero Pressure Output

±%FSO —

— 5

NovaSensor silicon sensors, the NPI-12 Series employs Sensitivity

mV/V/psi 0.19 0.20

0.21

SenStable® processing technology, which provides

Linearity, Hysteresis, Temperature Errors

±%FSO —

— 4.0 3

excellent output stability.

Response Time (10% to 90%) ms

— 1.0 — 4

The NPI-12 Series offers many features with superior

  1. Maximum change in diaphragm height relative to the edge of the sensor.

performance. The pressure sensitivity is calibrated at

  1. Supply current = 5 VDC and ambient temperature = 77°F (25°C), unless otherwise

0.20±0.01 mV/V/psi. The combined errors of linearity,

noted. 3. Best fit straight line.

pressure hysteresis, repeatability and temperature are

  1. For a zero-to-full scale pressure step change.

less than ±4 %FSO. The maximum overpressure is 50 psi (3.44 bar). A five volt excitation is needed to supply power to the device. The operating temperature range

for the NPI-12 Series is 50°F to 104°F (10°C to 40°C), while the storage temperature is -40°F to 158°F (–40°C to 70°C). Electrical connection is accomplished with a 4

pin connector that accepts standard 0.025 in (0.64 mm)

PDF page 2 diagram

square posts on 0.100 in (2.54 mm) centers. A red wire allows for easy recognition of connector orientation.

PDF page 2 diagram

NPI-12 Series schematic diagram

NPI-12 Series dimensions

Page 3

NPI-12 Series Specifications

Warranty

NovaSensor warrants its products against defects in material and workmanship for 12 months from the date of shipment . Products not subjected to misuse will be repaired or replaced. NovaSensor reserves the right to make changes without further notice to any products herein. NovaSensor makes no warranty, representation or guarantee regarding the suitability of its products for any particular application, nor does NovaSensor assume any liability arising out of the application or use of any product or circuit and specifically disclaims and all liability without limitation consequential or incidental damages. The foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory.

No Implied statutory warranty of merchantability or fitness for particular purpose shall apply.

Ordering Information

Part Number

Description

NPI-12-101GH

15 psi (1.03 bar)

Page 4

Amphenol

www.amphenol-sensors.com

© 2014 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice.

Advanced Sensors

Other company names and product names used in this document are the registered trademarks or trademarks of their respective owners.

AAS-920-259B 08/2014