Page 1

Product manual

Vandal-proof MSM DP switch

Contents

CONTENTS .......................................................................................................................................................... 1

1 PRODUCT DESCRIPTION ........................................................................................................................ 3

2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS ...................................................................... 3

2.1 Technical Data .................................................................................................................................................. 3

2.2 Component dimensions .................................................................................................................................... 6 2.2.1 Component dimensions MSM 19 DP ...................................................................................................................... 6 2.2.2 Component dimensions MSM 22 DP ...................................................................................................................... 7 2.2.3 Component dimensions MSM 30 DP ...................................................................................................................... 8

2.3 Actuator Tolerance Range ................................................................................................................................ 9

2.4 Hole dimensions ............................................................................................................................................. 10

2.5 Starting Torque .............................................................................................................................................. 11

2.6 Switching Symbols .......................................................................................................................................... 11

2.7 Accessories ..................................................................................................................................................... 11

3 ORDER NUMBERS .................................................................................................................................. 12

3.1 Order numbers MSM with micro switches of protection class IP40 (double‐pole) ............................................ 12

3.2 Lettering ........................................................................................................................................................ 13

4 PACKAGING ............................................................................................................................................. 15

5 QUALIFICATION TEST.......................................................................................................................... 16

5.1 IP Protection Class .......................................................................................................................................... 16

5.2 IK Protection Class .......................................................................................................................................... 16

5.3 ESD Protection ............................................................................................................................................... 16

5.4 Salt Spray Test ................................................................................................................................................ 16

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
1 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 2

6 APPROVALS ............................................................................................................................................. 17

7 ROHS COMPLIANT ................................................................................................................................ 17

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
2 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 3

1

PRODUCT DESCRIPTION

Both, the housing and the actuator of the vandal-proof MSM DP switch are made of high-quality stainless steel. By applying this robust and weather-resistant material, the switch is particularly suitable for the use in harsh environments. Furthermore, the switch can be used in applications where an additional second contact is required for a safety circuit. The MSM DP is available with mounting diameters of 19, 22 and 30 mm. The switch is equipped with two separated switching contacts which are available as normally open, normally closed or as change-over. Different types of contact cover a range of permissible switching voltages from 30 VDC to 250 VAC, switching currents are permissible from 0.1 to 10 Ampere. The MSM DP is

equipped with flat-pin plugs to permit fast connection. The cables are plugged onto the micro switch which is subsequently plugged onto the previously screwed-in switch. Point and ringilluminated versions are available for applications at night or as an optical status display.

TECHNICAL DATA AND DIMENSIONAL DRAWINGS

2

2.1 Technical Data

Micro Switch for Electrical Rating (Protection Class IP 40) 0.1 A 30 VDC 5 A 125 VAC 3 A 250 VAC 10 A 250 VAC
Electrical Data
Contact Material gold silver silver
(VAC) Switching Voltage max. (VDC) 30 125 / 250 250
Switching Current max. (A) 0.1 5 / 3 10
Rated Braking Capacity (W) 3 1250 2500
Lifetime 1) (at Rated Braking Capacity) 200,000 200,000 50,000
Lifetime (160mA at 48VDC) 1,500,000
Initial Contact Resistance, new (mΩ) < 50 < 30 < 30
Insulation Resistance (IEC 512-2) (MΩ) > 100 > 100 > 100
Contact Bounce Time (ms) < 5 < 5 < 5

1) The electrical lifetime according to ENEC or UL approbation can vary, depending on the corresponding micro switch, under the lifetime indicated above. The type and license numbers for the individual micro switches can be found in “point 6 approvals”.

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
3 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 4

Micro Switch for Electrical Rating (Protection Class IP 67) 0.1 A 250 VAC 5 A 250 VAC 10 A 250 VAC
Electrical Data
Switching Voltage max. (VAC) 250 250 250
Switching Current max. (A) 0.1 5 10
Rated Braking Capacity (W) 25 1500 2500
Lifetime 1) (at Rated Braking Capacity) 50,000 50,000 10,000

¾ Italically written types on request

1) The electrical lifetime according to ENEC or UL approbation can vary, depending on the corresponding micro switch, under the lifetime indicated above. The type and license numbers for the individual micro switches can be found in “point 6 approvals”.

PDF page 4 diagram
Ring Illumination
Supply Voltage (VDC) Ring Illumination 24

¾ Other supply voltages on request

\*The degree of protection refers to the area of the movable actuator.

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
4 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 5

Point Illumination Attention: Parts are delivered without series resistor.
Characteristics red LED Point Illumination Forward Current max. 40 mA Forward Voltage at 10 mA = 2.0 VDC Forward Voltage max. = 2.5 VDC
Characteristics green LED Point Illumination Forward Current max. 40 mA Forward Voltage at 10 mA = 2.0 VDC Forward Voltage max. = 2.5 VDC
Characteristics blue LED Point Illumination Forward Current max. 20 mA Forward Voltage at 10 mA = 3.2 VDC Forward Voltage max. = 3.7 VDC
Recommendation of series resistors for Point Illumination:
Material
Component Material
Housing Stainless Steel
Actuator Stainless Steel
Light Conductor (Point Illumination) PC
Illuminated Ring (Ring Illumination) PA
Gasket NBR70
Switcher Collet PA
Intermediate Connector non-illuminated PA
Intermediate Connector illuminated PA
Switcher Adapter PA
Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
5 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 6

2.2 Component dimensions

2.2.1 Component dimensions MSM 19 DP

MSM 19 DP ST

MSM 19 DP LE

C

C

22

PDF page 6 diagram
PDF page 6 diagram

MSM 19 DP PI

MSM 19 DP RI

C

C

PDF page 6 diagram
PDF page 6 diagram
PDF page 6 diagram

NO COM

Legend

  • A = Illumination Area
  • B = Actuating Area
  • C = Width Across Flats
  • D = Knurled Nut
Changes that contribute to technical improvement are subject to alternations
Seite Ers telldatum: Ersteller: Änderungsdatum: Geändert von: Än derungs-Nr. Datenblatt Nr. Index
6 of 17 07. 03.2008 Schillak Schöchlin 970 1 105.9534 a

Page 7

2.2.2 Component dimensions MSM 22 DP

MSM 22 DP ST

MSM 22 DP LE

PDF page 7 diagram
PDF page 7 diagram

MSM 22 DP PI

MSM 22 DP RI

PDF page 7 diagram
PDF page 7 diagram

Legend

  • A = Illumination Area
  • B = Actuating Area
  • C = Width Across Flats
  • D = Knurled Nut
Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
7 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 8

2.2.3 Component dimensions MSM 30 DP

MSM 30 DP ST

MSM 30 DP LE

PDF page 8 diagram
PDF page 8 diagram
PDF page 8 diagram
PDF page 8 diagram

MSM 30 DP PI

MSM 30 DP RI

PDF page 8 diagram
PDF page 8 diagram
PDF page 8 diagram
PDF page 8 diagram
PDF page 8 diagram
PDF page 8 diagram

Legend

  • A = Illumination Area
  • B = Actuating Area
  • C = Width Across Flats
  • D = Knurled Nut
Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Än derungs-Nr. Datenbla tt Nr. Index
8 of 17 07.03.2008 Schillak Schöchlin 97 01 105.9534 a

Page 9

2.3 Actuator Tolerance Range

PDF page 9 diagram
PDF page 9 diagram

The mounting tolerance range of the actuator varies from 0.2 mm projection length and 0.2 mm short length to the housing edge. The slanting position of the actuator can range within this tolerance.

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: E rsteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
9 of 17 07.03.2008 S chillak Schöchlin 9701 105.9534 a

Page 10

2.4 Hole dimensions

MSM 19 ST / MSM 19 RI

PDF page 10 diagram

MSM 22 ST / MSM 22 RI

PDF page 10 diagram

MSM 30 ST / MSM 30 RI

PDF page 10 diagram

MSM 19 LE/ MSM 19 PI / MSM 19 RI optional

PDF page 10 diagram

MSM 22 LE/ MSM 22 PI / MSM 22 RI optional

PDF page 10 diagram

MSM 30 LE / MSM 30 PI / MSM 30 RI optional

PDF page 10 diagram
Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
10 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 11

2.5 Starting Torque

Plastic Nut max. (Nm) Stainless Steel Nut * max. (Nm)
MSM 19 4.5 12
MSM 22 3.5 16
MSM 30 8 50

¾ \* on request

2.6 Switching Symbols

MSM ST / MSM LE

MSM PI

MSM RI

PDF page 11 diagram
PDF page 11 diagram

COM NO NC

COM NO NC

2.7 Accessories

MSM 22 Installation wrench

Order number: 1141.1337

PDF page 11 diagram
Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
11 of 17 07.03.2008 Schillak Schöchlin 9 701 105.9534 a

Page 12

3

ORDER NUMBERS

3.1 Order numbers MSM with micro switches of protection class IP40 (double-pole)

Mounting Diameter (mm)

Ø 19

Ø 22

Ø 30

Electrical Rating max. 5 A / 125 VAC or 3 A / 250 VAC
Standard 1241.6921.1120000 1241.6931.1120000 1241.6961.1120000
With Lettering 1241.6922.1120000 1241.6932.1120000 1241.6962.1120000
Point Illumination red 1241.6923.1121000 1241.6933.1121000 1241.6963.1121000
Point Illumination green 1241.6923.1122000 1241.6933.1122000 1241.6963.1122000
Point Illumination blue 1241.6923.1124000 1241.6933.1124000 1241.6963.1124000
Ring Illumination red 1241.6924.1121000 1241.6934.1121000 1241.6964.1121000
Ring Illumination green 1241.6924.1122000 1241.6934.1122000 1241.6964.1122000
Ring Illumination blue 1241.6924.1124000 1241.6934.1124000 1241.6964.1124000
Installation Wrench 1141.1337

¾ Italically written types on request ¾ At a minimum order quantity of 100 pieces the ring illuminated version with lettering is available on request.

Additional switch types with the following electrical ratings are available on request: 0.1 A@30VDC, 10A@250VAC and also 5A@250VAC with IP67 protection class. For these customized versions a minimum order quantity of 100 pieces has to be fulfilled.

For other types of the MSM product family, please visit:

http://www.schurter.de/wwwsc/con_pg70.asp?language_id=10

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
12 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 13

3.2 Lettering

The last three digits in the order number define the lettering.

000

No Lettering

001-072 Standard Lettering 101-

Customized Lettering

Example for ordering with lettering

Basic Version

1241.6611.1120XXX

Symbols 001-072

Ordering Indices for Lettering

016= P

001= A

031= 4

046=

061= EIN

017= Q

047= →

002= B

032= 5

062= AUS

048= ←

003= C

018= R

033= 6

063= AUF

049= ↓

004= D

019= S

034= 7

064= AB

050= ↑

005= E

020= T

035= 8

065= ON

021= U

006= F

036= 9

051= %

066= OFF

022= V

037= +

007= G

052= √

067= UP

023= W

008= H

038= −

053= CTRL

068= DOWN

024= X

054= RETURN

009= I

039= .

069= HIGH

025= Y

010= J

040= ×

070= LOW

055= SHIFT

026= Z

011= K

041= ÷

071= ON/OFF

056= LOCK

012= L

027= 0

042= ∗

057= STOP

072= START

013= M

028= 1

043= =

058= ENTER

014= N

029= 2

044= #

059= BACK

045= ↔

015= O

030= 3

060= LINE

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
13 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 14

Lettering Size

MSM 19 LE / MSM 19 PI :

Single characters:

height 8 mm, font: Helvetica normal DIN1451-1E height 3 mm, font: Helvetica normal DIN1451-1E

Text, max. 3 characters

height 2.5 mm, font: Helvetica condensed DIN1451-3E

Text, max. 6 characters:

capitals height 8 mm, font: True Type, Symbol

Symbols (indices 037-052):

MSM 22 LE / MSM 22 PI :

Single characters:

height 8 mm, font: Helvetica normal DIN1451-1E height 3 mm, font: Helvetica normal DIN1451-1E

Text, max. 3 characters

height 2.5 mm, font: Helvetica condensed DIN1451-3E

Text, max. 6 characters:

capitals height 8 mm, font: True Type, Symbol

Symbols (indices 037-052):

MSM 30 LE / MSM 30 PI :

height 12 mm, font: Helvetica normal DIN1451-1E

Single characters:

height 7 mm, font: Helvetica normal DIN1451-1E

Text, max. 3 characters:

height 3.5 mm, font: Helvetica condensed DIN1451-3E

Text, max. 6 characters:

capitals height 12 mm, font: True Type, Symbol

Symbols (indices 037-052):

MSM 19 RI \* / MSM 22 RI \*:

height 5 mm, font: Helvetica normal DIN1451-1E

Single characters:

height 3 mm, font: Helvetica normal DIN1451-1E

Text, max. 3 characters Symbols (indices 037-052):

capitals height 5 mm, font: True Type, Symbol

MSM 30 RI \*:

height 8 mm, font: Helvetica normal DIN1451-1E

Single characters:

height 3 mm, font: Helvetica normal DIN1451-1E

Text, max. 3 characters:

height 2.5 mm, font: Helvetica condensed DIN1451-3E

Text, max. 6 characters:

capitals height 8 mm, font: True Type, Symbol

Symbols (indices 037-052):

¾ \* At a minimum order quantity of 100 pieces the ring illuminated version with lettering is available on request.

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
14 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 15

4

PACKAGING

MSM Switch

MSM 19 10 pieces per box with inlay
MSM 22 10 pieces per box with inlay
MSM 30 1 piece in air cushion bag 10 pieces per box

The nuts with gaskets and corresponding micro switches are packed separately and enclosed in the box.

PDF page 15 diagram
Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
15 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 16

5

QUALIFICATION TEST

5.1 IP Protection Class

IP Protection Class IEC/DIN/EN/ 60529

IP 67

5.2 IK Protection Class Tested Centrically

IK Protection Class DIN EN 50102

IK 07

5.3 ESD Protection ESD-Test according to DIN 61000-4-2:

4kV Contact Discharge MSM DP ST Ø 19; 22; 30 mm
4kV Contact Discharge MSM DP LE Ø 19; 22; 30 mm

5.4 Salt Spray Test

Salt spray test according to DIN 50021- SS 24h, 48h and 96h residence time The surface of the stainless steel material is covered with a molecular-passive layer. Only under very unfavourable conditions it is possible, that iron and rust molecules as well as base metals penetrate the passive layer as foreign substances (pollutions) and initiate the rust process. The smoothness of the actuator was not affected. After the residence time the tested samples were cleaned under running water and all rust spots could be removed.

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
16 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a

Page 17

6

APPROVALS

The listed approvals only refer to the micro switch and not to the complete switch.

Micro switch:

Type Licence number ENEC VDE / KEMA UL 1054 CSA C22.2 NO55
1050.1151 097550 DIN EN 61058 E41791
1050.1102 097550 DIN EN 61058 E41791
1050.1103 097550 DIN EN 61058 E41791
SS-01 T 40008425 DIN EN 61058 E41515
SS-5 T 129246 DIN EN 61058 E41515
SS-10 T 125256 DIN EN 61058 E41515
DC3GL1AA 2089323.01 DIN EN 61058 E23301
DC1GL1AA 2089323.01 DIN EN 61058 E23301
DC2GL1AA 2089323.01 DIN EN 61058 E23301

7

ROHS COMPLIANT

All articles are ROHS-compliant.

Changes that contribute to technical improvement are subject to alternations
Seite Erstelldatum: Ersteller: Änderungsdatum: Geändert von: Änderungs-Nr. Datenblatt Nr. Index
17 of 17 07.03.2008 Schillak Schöchlin 9701 105.9534 a