MPY100 BURR-BROWN

Document overview

  • PDF pages: 12

Technical content

Page 1

PDF page 1 diagram

Page 2

SPECIFICATIONS

At TA = +25°C and ±VS = 15VDC, unless otherwise specified.

PDF page 2 diagram

Page 3

SPECIFICATIONS (CONT)

At TA = +25°C and ±VS = 15VDC, unless otherwise specified.

PDF page 3 diagram

\* Same as MPY100A specification. \*/\* B/C grades same as MPY100A specification. NOTES: (1) Includes effects of recommended null pots. (2) Z2 input resistance is 10MΩ, typical, with VOS pin open. If VOS pin is grounded or used for optional offset adjustment, the Z2 input resistance may be as low as 25kΩ

PIN CONFIGURATIONS

PDF page 3 diagram
PDF page 3 diagram

ORDERING INFORMATION

MODEL PACKAGE TEMPERATURE RANGE
MPY100AG MPY100AM MPY100BG MPY100BM MPY100CG MPY100CM MPY100SG MPY100SM 14-Pin Ceramic DIP Metal TO-100 14-Pin Ceramic DIP Metal TO-100 14-Pin Ceramic DIP Metal TO-100 14-Pin Ceramic DIP Metal TO-100 –25°C to +85°C –25°C to +85°C –25°C to +85°C –25°C to +85°C –25°C to +85°C –25°C to +85°C –55°C to +125°C –55°C to +125°C

ABSOLUTE MAXIMUM RATINGS

PDF page 3 diagram

PACKAGE INFORMATION

PDF page 3 diagram

NOTE: (1) For detailed drawing and dimension table, please see end of data sheet, or Appendix D of Burr-Brown IC Data Book.

Page 4

SIMPLIFIED SCHEMATIC

PDF page 4 diagram

CONNECTION DIAGRAM

PDF page 4 diagram

DICE INFORMATION

PDF page 4 diagram
PDF page 4 diagram
PDF page 4 diagram
MILS (0.001") MILLIMETERS
Die Size Die Thickness Min. Pad Size 107 x 93 ±5 20 ±3 4 x 4 2.72 x 2.36 ±0.13 0.51 ±0.08 0.10 x 0.10
Backing Gold

MPY100 DIE TOPOGRAPHY

Page 5

TYPICAL PERFORMANCE CURVES

At TA = +25°C and ±VS = 15VDC, unless otherwise specified.

NONLINEARITY vs FREQUENCY

TOTAL ERROR vs AMBIENT TEMPERATURE

PDF page 5 diagram
PDF page 5 diagram

0.001 10

–100 –50 0

100 150

50

Ambient Temperature (°C)

FEEDTHROUGH vs FREQUENCY

100 1k

100k 1M

10k Frequency (Hz)

OUTPUT AMPLITUDE vs FREQUENCY

PDF page 5 diagram
PDF page 5 diagram

10k

1k 10k 100k

10 100

1M 10M

Frequency (Hz)

LARGE SIGNAL RESPONSE

100k

1M

10M

Frequency (Hz)

INPUT VOLTAGE FOR LINEAR RESPONSE

PDF page 5 diagram
PDF page 5 diagram

3

0 1 2

4 5

0 2

8 10 12 14 16 18 20 4 6 Power Supply Voltage (±VCC)

Time (µs)

Page 6

TYPICAL PERFORMANCE CURVES (CONT)

At TA = +25°C and ±VS = 15VDC, unless otherwise specified.

COMMON-MODE REJECTION vs FREQUENCY

PDF page 6 diagram

1k 10k 100k

10 100

1M 10M

Frequency (Hz)

OUTPUT VOLTAGE vs OUTPUT CURRENT

PDF page 6 diagram

4 6 8

14

0 2

10 12 16

Output Current (±mA)

SUPPLY CURRENT vs AMBIENT TEMPERATURE

PDF page 6 diagram

50

–100 –50 0

100 150

Ambient Temperature (°C)

Page 7

THEORY OF OPERATION

The MPY100 is a variable transconductance multiplier consisting of three differential voltage-to-current converters, a multiplier core and an output differential amplifier as illustrated in Figure 1. The basic principle of the transconductance multiplier can be demonstrated by the differential stage in Figure 2. For small values of the input voltage, V1, that are much smaller than VT, the transistor’s thermal voltage, the differential output voltage, VO, is:

VO = gm RLV1

The transconductance gm of the stage is given by:

gm = IE/VT

PDF page 7 diagram

FIGURE 1. MPY100 Functional Block Diagram.

PDF page 7 diagram

FIGURE 2. Basic Differential Stage as a Transconductance Multiplier.

and is modulated by the voltage, V2, to give

gm ≈ V2/VTRE

Substituting this into the original equation yields the overall transfer function VO = gmRLV1 = V1V2 (RL/VTRE) which shows the output voltage to be the product of the two input voltages, V1 and V2. Variations in IE due to V2 cause a large common-mode voltage swing in the circuit. The errors associated with this common-mode voltage can be eliminated by using two differential stages in parallel and cross-coupling their outputs as shown in Figure 3.

PDF page 7 diagram

FIGURE 3. Cross-Coupled Differential Stages as a Variable- Transconductance Multiplier.

An analysis of the circuit in Figure 3 shows it to have the same overall transfer function as before:

VO = V1V2 (RL/VTRE).

For input voltages larger than VT, the voltage-to-current transfer characteristics of the differential pair Q1, Q2 or Q3 and Q4 are no longer linear. Instead, their collector currents are related to the applied voltage V1

V1

I1 I3

VT = = e I2 I4

The resultant nonlinearity can be overcome by developing V1 logarithmically to exactly cancel the exponential relationship just derived. This is done by diodes D1 and D2 in Figure 4. The emitter degeneration resistors, RX and RY, in Figure 4, provide a linear conversion of the input voltages to differential current, IX and IY, where:

Page 8

IX = VX/RX and IY = VY/RY

Analysis of Figure 4 shows the voltage VA to be:

VA = (2RL/I1)(IXIY)

Since IX and IY are linearly related to the input voltages VX and VY, VA may also be written:

VA = KVXVY

where K is a scale factor. In the MPY100, K is chosen to be 0.1. The addition of the Z input alters the voltage VA to:

VA = KVXVY – VZ

Therefore, the output of the MPY100 is:

VO = A[KVXVY – VZ]

where A is the open-loop gain of the output amplifier. Writing this last equation in terms of the separate inputs to the MPY100 gives

(X1 – X2)(Y1 – Y2) VO = A – (Z1 – Z2)

10

the transfer function of the MPY100.

WIRING PRECAUTIONS

In order to prevent frequency instability due to lead inductance of the power supply lines, each power supply should be bypassed. This should be done by connecting a 10µF tantalum capacitor in parallel with a 1000pF ceramic capacitor from the +VCC and –VCC pins of the MPY100 to the power supply common. The connection of these capacitors should be as close to the MPY100 as practical.

CAPACITIVE LOADS

Stable operation is maintained with capacitive loads to 1000pF in all modes, except the square root mode for which 50pF is a safe upper limit. Higher capacitive loads can be driven if a 100Ω resistor is connected in series with the MPY100’s output.

DEFINITIONS

TOTAL ERROR (Accuracy) Total error is the actual departure of the multiplier output voltage form the ideal product of its input voltages. It includes the sum of the effects of input and output DC offsets, gain error and nonlinearity.

OUTPUT OFFSET

Output offset is the output voltage when both inputs VX and VY are 0V.

SCALE FACTOR ERROR

Scale factor error is the difference between the actual scale factor and the ideal scale factor.

NONLINEARITY

Nonlinearity is the maximum deviation from a best straightline (curve fitting on input-output graph) expressed as a percent of peak-to-peak full scale output.

FEEDTHROUGH

Feedthrough is the signal at the output for any value of VX or VY within the rated range, when the other input is zero.

PDF page 8 diagram

FIGURE 4. MPY100 Simplified Circuit Diagram.

Page 9

SMALL SIGNAL BANDWIDTH

Small signal bandwidth is the frequency at which the output is down 3dB from its low-frequency value for nominal output amplitude of 10% of full scale.

1% AMPLITUDE ERROR

The 1% amplitude error is the frequency the output amplitude is in error by 1%, measured with an output amplitude of 10% of full scale.

1% VECTOR ERROR

The 1% vector error is the frequency at which a phase error of 0.01 radians (0.57°) occurs. This is the most sensitive measure of dynamic error of a multiplier.

TYPICAL APPLICATIONS

MULTIPLICATION

Figure 5 shows the basic connection for four-quadrant multiplication. The MPY100 meets all of its specifications without trimming. Accuracy can, however be improved over a limited range by nulling the output offset voltage using the 100Ω optional balance potentiometer shown in Figure 5. AC feedthrough may be reduced to a minimum by applying an external voltage to the X or Y input as shown in Figure 6. Z2, the optional summing input, may be used to sum a voltage into the output of the MPY100. If not used, this terminal, as well as the X and Y input terminals, should be grounded. All inputs should be referenced to power supply common. Figure 7 shows how to achieve a scale factor larger than the

nominal 1/10. In this case, the scale factor is unity which makes the transfer function

1 + (R1/R2)

VO = KVXVY = K(X1 – X2)(Y1 – Y2).

K = 10 0.1 ≤ K ≤ 1

This circuit has the disadvantage of increasing the output offset voltage by a factor of 10, which may require the use of the optional balance control as in Figure 1 for some applications. In addition, this connection reduces the small signal bandwidth to about 50kHz.

DIVISION

Figure 8 shows the basic connection for two-quadrant division. This configuration is a multiplier-inverted analog divider, i.e., a multiplier connected in the feedback loop of an operational amplifier. In the case of the MPY100, this operational amplifier is the output amplifier shown in Figure 1. The divider error with a multiplier-inverted analog divider is approximately:

εDIVIDER = 10 εMULTIPLIER/(X1 – X2) It is obvious from this error equation that divider error becomes excessively large for small values of X1 – X2. A 10- to-1 denominator range is usually the practical limit. If more accurate division is required over a wide range of denominator voltages, an externally generated voltage may be

PDF page 9 diagram

FIGURE 5. Multiplier Connection.

PDF page 9 diagram

FIGURE 6. Optional Trimming Configuration.

PDF page 9 diagram

FIGURE 7. Connection for Unity Scale Factor.

PDF page 9 diagram

FIGURE 8. Divider Connection.

Page 10

applied to the unused X-input (see Optional Trim Configuration). To trim, apply a ramp of +100mV to +1V at 100Hz to both X1 and Z1 if X2 is used for offset adjustment, otherwise reverse the signal polarity and adjust the trim voltage to minimize the variation in the output. An alternative to this procedure would be to use the Burr-Brown DIV100, a precision log-antilog divider.

SQUARING

PDF page 10 diagram

FIGURE 9. Squarer Connection.

SQUARE ROOT

Figure 10 shows the connection for taking the square root of the voltage VZ. The diode prevents a latching condition which could occur if the input momentarily changed polarity. This latching condition is not a design flaw in the MPY100, but occurs when a multiplier is connected in the feedback loop of an operational amplifier to perform square root functions. The load resistance, RL, must be in the range of 10kΩ ≤ RL ≤ 1MΩ. This resistance must be in the circuit as it provides the current necessary to operate the diode.

PERCENTAGE COMPUTATION

The circuit of Figure 11 has a sensitivity of 1V/% and is capable of measuring 10% deviations. Wider deviation can be measured by decreasing the ratio of R2/R1.

BRIDGE LINEARIZATION

The use of the MPY100 to linearize the output from a bridge circuit makes the output VO independent of the bridge supply voltage. See Figure 12.

TRUE RMS-TO-DC CONVERSION

The rms-to-DC conversion circuit of Figure 13 gives greater accuracy and bandwidth but with less dynamic range than most rms-to-DC converters.

SINE FUNCTION GENERATOR

The circuit in Figure 14 uses implicit feedback to implement the following sine function approximation: VO = (1.5715V1 – 0.004317V13)/(1 + 0.001398V12) = 10 sin (9V1)

MORE CIRCUITS

The theory and procedures for developing virtually any function generator or linearization circuit can be found in the Burr-Brown/McGraw Hill book “FUNCTION CIRCUITS - Design and Applications.”

PDF page 10 diagram

FIGURE 10. Square Root Connection.

PDF page 10 diagram

FIGURE 11. Percentage Computation.

Page 11

PDF page 11 diagram

FIGURE 12. Bridge Linearization.

PDF page 11 diagram

FIGURE 13. True RMS-to-DC Conversion.

Page 12

PDF page 12 diagram

FIGURE 14. Sine Function Generator

PDF page 12 diagram

FIGURE 15. Single-Phase Instantaneous and Real Power

Measurement.

The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant any BURR-BROWN product for use in life support devices and/or systems.