DATASHEET SEARCH SITE

Document overview

  • PDF pages: 2

Technical content

Page 1

PDF page 1 diagram

Through-hole resistors

General Type

Normal & Miniature Style [ MFR Series ]

PDF page 1 diagram

FEATURES

Power Rating

Resistance Tolerance

T.C.R.

DERATING CURVE

1/6W, 1/4W, 1/2W, 1W, 2W, 3W

±0.5%, ±1%, ±5%

±15ppm/°C, ±25ppm/°C, ±50ppm/°C, ±100ppm/°C

For resistors operated in ambient temperatures above 70°C, power rating must be derated

INTRODUCTION

in accordance with the curve below.

The MFR Series Metal Film Resistors are

70

155 °C

Rated Load (%)

PDF page 1 diagram

manufactured using a vacuum sputtering system to deposit multiple layers of mixed metal alloys and passivative materials onto a carefully treated high grade ceramic substrate. After a helical groove has been cut in the resistive layer, tinned connecting leads of electrolytic copper

Ambient Temperature (°C)

are welded to the end-caps. The resistors are coated with layers of blue color lacquer.

DIMENSIONS

Unit: mm

STYLE

DIMENSION

Normal

Miniature

L

øD

H

ød

MFR-12

MFR25S

3.4±0.3

1.9±0.2

28±2.0

0.45±0.05

PDF page 1 diagram

ød MFR-25

MFR50S

6.3±0.5

2.4±0.2

28±2.0

0.55±0.05

MFR-50

MFR1WS

9.0±0.5

3.3±0.3

26±2.0

0.55±0.05

MFR100

MFR2WS

11.5±1.0

4.5±0.5

35±2.0

0.8±0.05

MFR200

MFR3WS

15.5±1.0

5.0±0.5

33±2.0

0.8±0.05

Page 2

5

PDF page 2 diagram

ELECTRICAL CHARACTERISTICS

STYLE

MFR-12 MFR25S MFR-25 MFR50S

MFR-50 MFR1WS MFR100 MFR2WS MFR200 MFR3WS

Power Rating at 70°C

1/6W 1/4W

1/2W

1W

2W

3W

Maximum Working Voltage

200V

250V 300V 350V 400V 500V

Maximum Overload Voltage

400V

500V 600V 700V 800V 1,000V

Voltage Proof on Insulation

300V 400V 500V

700V 1,000V

Resistance Range

1Ω - 10MΩ & 0Ω for E24 & E96 series value

Operating Temp. Range

-55°C to +155°C

Temperature Coefficient

±15ppm/°C, ±25ppm/°C, ±50ppm/°C, ±100ppm/°C

Note: Special value is available on request

ENVIRONMENTAL CHARACTERISTICS

PERFORMANCE TEST

TEST METHOD

APPRAISE

Short Time Overload

IEC 60115-1 4.13 2.5 times RCWV for 5 Sec.

±0.25%+0.05Ω

in V-block for 60 Sec., test voltage by type

Voltage Proof on Insulation

IEC 60115-1 4.7

Temperature Coefficient

IEC 60115-1 4.8

-55°C to +155°C

Insulation Resistance

IEC 60115-1 4.6

in V-block for 60 Sec.

Solderability

IEC 60115-1 4.17 235±5°C for 3±0.5 Sec.

Solvent Resistance of Marking

IEC 60115-1 4.30 IPA for 5±0.5 Min. with ultrasonic

By type

By type

10,000MΩ

95% Min. coverage

No deterioration of coatings and markings

IEC 60115-1 4.16 Direct load for 10 Sec. in the direction of the terminal leads

Robustness of Terminations

≥2.5kg (24.5N)

IEC 60115-1 4.39 4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec. off)

Periodic-pulse Overload

±1.0%+0.05Ω

IEC 60115-1 4.24 40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV

Damp Heat Steady State

±1.5%+0.05Ω

IEC 60115-1 4.25 70±2°C at RCWV for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off)

Endurance at 70°C

±1.5%+0.05Ω

-55°C  Room Temp.  +155°C  Room Temp. (5 cycles)

Temperature Cycling

IEC 60115-1 4.19

±0.75%+0.05Ω

IEC 60115-1 4.18 260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body

Resistance to Soldering Heat

±0.25%+0.05Ω

Note: RCWV(Rated Continuous Working Voltage) = Power Rating x Resistance Value or Max. working voltage listed above, whichever less.

Revision: 201304